scholarly journals Marginal Adaptation of Nanofilled, Packable and Hybrid Dental Composite Resins Stored in Artificial Saliva

2012 ◽  
Vol 2 (3) ◽  
pp. 105-114
Author(s):  
Mohamed El-Nawawy ◽  
Lubna Koraitim ◽  
Ossama Abouelatta ◽  
Hanan Hegazi
2019 ◽  
Vol 56 (2) ◽  
pp. 434-439
Author(s):  
Cristina-Angela Ghiorghe ◽  
Vlad Carlescu ◽  
Claudiu Topoliceanu ◽  
Irina Nica ◽  
Galina Pancu ◽  
...  

The aim of this study was to evaluate the microhardness Rockwell and Young s modulus of a new nano-hybrid and nano-fill composite resins exposed to corrosive media. The study was performed on two composite resins, one nano-hybrid and one nano-fill, enamel, dentine, translucent, respectively body shade, of which were made 20 samples (25.0 � 0.1 mm lengths, 10.0 � 0.1 mm widths and 3.0 � 0.1 mm thicknesses), which were immersed in mouthwash for 1 minute per day for 10 days, the rest of the time being stored in artificial saliva. Measurements of Rockwell microhardness and Young�s modulus on samples were made between on the first day, after 6 days and 10 days of immersion in mouthwash comparative with 0 day. The results showed that after immersion in the corrosive environment, both materials had the hardness values changed, but medium values of Rockwell microhardness to nano-fill composite resin were higher than nano-hybride. At the nano-hybride composite resin, it was observed that the enamel and clear translucent groups had the mean values increased after the first day of exposure to mouthwash, compared to the dentine group, which showed a higher mean value after 6 days. At the nano-fill composite resin, for the enamel and body groups were obtained the higher values of HRC after 10 days. For the dentine group, after 6 days, Filtek Ultimate showed the same variation as Harmonize dentine shade. Harmonize composite resin showed higher values of Rockwell microhardness and Young�s modulus for all study groups compared to Filtek Ultimate.


2018 ◽  
Vol 66 (1) ◽  
pp. 15-20
Author(s):  
Tamara Carolina TREVISAN ◽  
Marcelo GUSSON JÚNIOR ◽  
Janaína Freitas BORTOLATTO ◽  
Suzane PIGOSSI ◽  
Osmir Batista de OLIVEIRA JÚNIOR ◽  
...  

ABSTRACT Objective: This study compared the color stability of different dental composite resins after prolonged exposure to a coffee solution. Methods: Sixty-four cylindrical discs (10 mm diameter x 2 mm thickness) were prepared using 8 different dental composite resins (n=8, per group). The specimens were first immersed in artificial saliva for 24 h followed by immersion in a coffee solution for 14 days. The assessment of chromatic variation (ΔE) was performed with the aid of a Vita Easyshade Advanced spectrophotometer (VITA Zahnfabrik, Bad Sackingen, Germany). The color of each specimen was calculated based on the L*, a* and b* coordinates of the CIELab system. Results: Grandio SO had the lowest average chromatic variation (ΔE=7.77) after immersion in coffee solution. Durafill VS, Grandio and Z350 XT (ΔE=8.58; ΔE=9.52; ΔE=10.39, respectively) showed similar chromatic variation, with no statistical difference in relation to Grandio SO. However, the other dental composite resins evaluated showed statistically higher values of ΔE compared to Grandio SO, and Enamel HRi (ΔE=20.56) demonstrated the highest chromatic variation. Conclusion: The Bulk Fill and hybrid composite resins from the same manufacturer (Micerium, Avegno, Italy) showed greater chromatic variation than the other composite resins tested. Grandio SO (Voco, Cuxaven, Germany) had the lowest ΔE variation.


2019 ◽  
Vol 56 (3) ◽  
pp. 529-533
Author(s):  
Mihaela Pantea ◽  
Diana Andreea Ighigeanu ◽  
Alexandra Totan ◽  
Maria Greabu ◽  
Daniela Miricescu ◽  
...  

This in vitro study analyses the biochemical interaction between saliva and three types of dental composite resins (a direct resin, an indirect resin and a dual-cure resin used for cementation of indirect dental restorations). The resin samples were obtained following a specific protocol and in line with the producers� recommendations; the resin samples were incubated with saliva samples collected from 19 healthy volunteers. The obtained results showed that the tested composite resins did not produce significant changes in oxidative stress parameters that were analysed (albumin, uric acid, GGT / gamma glutamyl transferase, OXSR-1 / oxidative stress responsive kinase 1) and do not influence the inflammatory salivary status reflected by the levels of IL-6 - an inflammatory marker.


1991 ◽  
Vol 1 (4) ◽  
pp. 223-231
Author(s):  
Y. Higo ◽  
D. Damri ◽  
S. Nunomura ◽  
K. Kumada ◽  
N. Sawa ◽  
...  

2009 ◽  
Vol 28 (4) ◽  
pp. 438-445 ◽  
Author(s):  
Tae-Sung JEONG ◽  
Ho-Seung KANG ◽  
Sung-Ki KIM ◽  
Shin KIM ◽  
Hyung-Il KIM ◽  
...  

2011 ◽  
Vol 75 (6) ◽  
pp. 758-765 ◽  
Author(s):  
Alessandra N.S. Rastelli ◽  
Denis P. Jacomassi ◽  
Ana Paula S. Faloni ◽  
Thallita P. Queiroz ◽  
Seila S. Rojas ◽  
...  

2017 ◽  
Vol 33 (8) ◽  
pp. e310-e316 ◽  
Author(s):  
Karine Haas ◽  
Gulelala Azhar ◽  
Duncan J. Wood ◽  
Keyvan Moharamzadeh ◽  
Richard van Noort

2006 ◽  
Vol 31 (4) ◽  
pp. 312 ◽  
Author(s):  
Kyu-Jeong Cho ◽  
Su-Jung Park ◽  
Hyun-Gu Cho ◽  
Dong-Jun Kim ◽  
Yun-Chan Hwang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document