scholarly journals Numerical Study of the Performance Characteristics of a Cascade Heat Pump Water Heater at Low Ambient Temperatures

Author(s):  
Jaehyun Song ◽  
Haewon Jung ◽  
JaeWoo Park ◽  
Hoon Kang ◽  
Yongchan Kim
Author(s):  
Jielin Luo ◽  
Qin Wang ◽  
Zhen Zhao ◽  
Kaiyin Yang ◽  
Guangming Chen ◽  
...  

Abstract Considering the issues of environmental pollution and energy efficiency, heat pumps are gradually replacing traditional coal combustion for heating at low ambient temperatures. In this paper, eco-friendly CO2/HCs with large temperature glides are applied in a single-stage recuperative heat pump water heater. Its heating performance is theoretically investigated under the working condition of producing circulating hot water in typical winter of northern China, with medium temperature difference between supply/return water and large temperature difference between air inlet and water inlet. Due to its simple structure, low initial investment and high efficiency, its potential for producing circulating hot water is demonstrated. Exergy analyses are conducted to reveal the significant influence of the exergy losses of heat exchanger on system performance. For specified CO2/HC, optimal COP is obtained through global optimization of cycle pressures and mixture concentration. The heating performances of different CO2/HCs are compared, among which CO2/R600 and CO2/R600a behave better. Meanwhile, a typical vapor-injection cycle is used to demonstrate priorities on the heating performance of this recuperative cycle, in which the COP of recuperative cycle using CO2/R600 is more than 3.4% higher than that of the vapor-injection cycle. The results obtained in this paper provide a simple and efficient solution for producing circulating hot water at low ambient temperatures.


2021 ◽  
Vol 2116 (1) ◽  
pp. 012098
Author(s):  
F Illán-Gómez ◽  
J R García-Cascales ◽  
F J Sánchez-Velasco ◽  
V Sena-Cuevas ◽  
R Otón-Martínez

Abstract This paper presents a numerical study on the influence of internal heat exchanger (IHX) exchanging surface in the performance of a transcritical CO2 heat pump water heater at different operating conditions. Five different IHX geometries and four different evaporation temperatures have been studied with water temperature ranging from 10 °C to 60 °C at the gas cooler inlet. The results show a strong influence of IHX characteristics on system’s performance.


Author(s):  
Toshikazu ISHIHARA ◽  
Hiroshi MUKAIYAMA ◽  
Osamu KUWABARA ◽  
Toshiyuki EBARA ◽  
Hirokazu IZAKI ◽  
...  

1979 ◽  
Author(s):  
J.T. Dieckmann ◽  
A.J. Erickson ◽  
A.C. Harvey ◽  
W.M. Toscano

2021 ◽  
Vol 39 ◽  
pp. 102547
Author(s):  
Sami Missaoui ◽  
Zied Driss ◽  
Romdhane Ben Slama ◽  
Bechir Chaouachi

2016 ◽  
Author(s):  
Gabriel Agila ◽  
Guillermo Soriano

This research develops a detailed model for a Water to Water Heat Pump Water Heater (HPWH), operating for heating and cooling simultaneously, using two water storage tanks as thermal deposits. The primary function of the system is to produce useful heat for domestic hot water services according to the thermal requirements for an average household (two adults and one child) in the city of Quito, Ecuador. The purpose of the project is to analyze the technical and economic feasibility of implementing thermal storage and heat pump technology to provide efficient thermal services and reduce energy consumption; as well as environmental impacts associated with conventional systems for residential water heating. An energy simulation using TRNSYS 17 is carried to evaluate model operation for one year. The purpose of the simulation is to assess and quantifies the performance, energy consumption and potential savings of integrating heat pump systems with thermal energy storage technology, as well as determines the main parameter affecting the efficiency of the system. Finally, a comparative analysis based on annual energy consumption for different ways to produce hot water is conducted. Five alternatives were examined: (1) electric storage water heater; (2) gas fired water heater; (3) solar water heater; (4) air source heat pump water heater; and (5) a heat pump water heater integrated with thermal storage.