scholarly journals Bioanalytical method development and validation of HPLCUV assay for the quantification of SHetA2 in mouse and human plasma: Application to pharmacokinetics study

2017 ◽  
Vol 6 (1) ◽  
pp. 2 ◽  
Author(s):  
Ankur Sharma ◽  
Elangovan Thavathiru ◽  
Doris Mangiaracina Benbrook ◽  
Sukyung Woo
Author(s):  
Marakatham S. ◽  
Shanmugapandiyan P.

A novel, simple and sensitive bioanalytical method was developed for estimation of Doravirine, Lamavudine and tenofovir disoproxil fumarate in human plasma with daclatasvir as internal standard. The method was developed using alliance HPLC using Phenomenex C18 (150mm x 4.6mm, 5m) column with mobile phase of 0.01N Potassium dihydrogen phosphate pH (3.5): Acetonitrile (60:40) at flow rate of 1.0ml/min. Detection wavelength was found to be 277nm. The linearity range for doravirine, lamuvidine and Tenfovir was 50-2000ng/ml, 125-5000ng/ml and 20-800ng/ml. Correlation coefficient was 0.999. The method was validated and stability study was carried out as per FDA guidelines.


Author(s):  
S. SATHESHKUMAR ◽  
V. MURUGANANTHAM

Objective: The current research work focus to simple and rugged bioanalytical method development and validation of brivudine in human plasma using high-performance liquid chromatography. Methods: The analyte (Brivudine) and internal standard (Sofosbuvir) were extracted using the Solid Phase Extraction (SPE) technique. The chromatographic separation was accomplished by using Zorbax eclipse XDB-C18 Column (150×4.6 mm, 5 μm) with a mobile phase consisted of Methanol: 0.5% Ortho-phosphoric acid (65:35%, v/v) respectively, at a flow rate of 0.7 mL/min. The developed method was validated by performing system suitability, carryover effect, linearity, selectivity, sensitivity, precision, accuracy, recovery, ruggedness, and stability studies. The method was validated as per USFDA guidelines. Results: The selected chromatographic condition was found to efficiently separated brivudine (RT-3.55 min) and ISTD (RT-7.87 min). The assay demonstrated a linear dynamic range of 85.205 to 4500.246 ng/ml for brivudine in human plasma with r2>0.99. Demonstrated the lowest limit of detection at 85.205 ng/ml. This method established an intra-run and inter-run precision within the range of 2.99-6.31%CV and 3.67-5.80%CV, respectively. Additional intra-run and inter-run accuracy were within the range of 97.55-105.37% and 99.27-102.15%, respectively. The mean percentage recovery of brivudine and ISTD studies proved good extraction efficiency and the robustness was also evaluated. Conclusion: A simple, accurate, precise, linear and rugged RP-HPLC method was developed and validated for the estimation of brivudine in human plasma with K2EDTA anticoagulant and suitable for conducting BA/BE and TDM.


Sign in / Sign up

Export Citation Format

Share Document