scholarly journals A SIMPLE AND RUGGED BIOANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF BRIVUDINE IN HUMAN PLASMA BY USING HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY

Author(s):  
S. SATHESHKUMAR ◽  
V. MURUGANANTHAM

Objective: The current research work focus to simple and rugged bioanalytical method development and validation of brivudine in human plasma using high-performance liquid chromatography. Methods: The analyte (Brivudine) and internal standard (Sofosbuvir) were extracted using the Solid Phase Extraction (SPE) technique. The chromatographic separation was accomplished by using Zorbax eclipse XDB-C18 Column (150×4.6 mm, 5 μm) with a mobile phase consisted of Methanol: 0.5% Ortho-phosphoric acid (65:35%, v/v) respectively, at a flow rate of 0.7 mL/min. The developed method was validated by performing system suitability, carryover effect, linearity, selectivity, sensitivity, precision, accuracy, recovery, ruggedness, and stability studies. The method was validated as per USFDA guidelines. Results: The selected chromatographic condition was found to efficiently separated brivudine (RT-3.55 min) and ISTD (RT-7.87 min). The assay demonstrated a linear dynamic range of 85.205 to 4500.246 ng/ml for brivudine in human plasma with r2>0.99. Demonstrated the lowest limit of detection at 85.205 ng/ml. This method established an intra-run and inter-run precision within the range of 2.99-6.31%CV and 3.67-5.80%CV, respectively. Additional intra-run and inter-run accuracy were within the range of 97.55-105.37% and 99.27-102.15%, respectively. The mean percentage recovery of brivudine and ISTD studies proved good extraction efficiency and the robustness was also evaluated. Conclusion: A simple, accurate, precise, linear and rugged RP-HPLC method was developed and validated for the estimation of brivudine in human plasma with K2EDTA anticoagulant and suitable for conducting BA/BE and TDM.

2021 ◽  
pp. 1-11
Author(s):  
Sultan M. Alshahrani ◽  
John Mark Christensen

This study was designed to develop and validate a simple and efficient high performance liquid chromatography (HPLC) method to determine flunixin concentrations in Asian elephant’s (Elephas maximus) plasma. Flunixin was administered orally at a dose of 0.8 mg/kg, and blood samples were collected. Flunixin extraction was performed by adding an equal amount of acetonitrile to plasma and centrifuging at 4500 rpm for 25 minutes. The supernatant was removed, and flunixin was analyzed using HPLC-UV detection. Two methods were developed and tested utilizing two different mobile phases either with or without adding methanol (ACN: H2O vs. ACN: H2O: MeOH). Both methods showed excellent linearity and reproducibility. The limit of detection was 0.05 ug/ml and limit of quantification was 0.1 ug/ml. the efficiency of flunixin recovery was maximized by the addition of methanol to mobile phase (ACN: H2O: MeOH as 50:30:20) at 95% in comparison to 23% without methanol. In conclusion, adding methanol to HPLC methods for extraction of flunixin from elephants’ plasma yielded higher recovery rate than without methanol.


Sign in / Sign up

Export Citation Format

Share Document