scholarly journals Peer Review #3 of "Upper-room ultraviolet air disinfection might help to reduce COVID-19 transmission in buildings: a feasibility study (v0.2)"

Author(s):  
H Woodward
Author(s):  
Clive B. Beggs ◽  
Eldad J. Avital

AbstractAs the world economies get out of the lockdown imposed by the COVID-19 pandemic, there is an urgent need to assess the suitability of known technologies to mitigate COVID-19 transmission in confined spaces such as buildings. This feasibility study looks at the method of upper-room ultraviolet (UV) air disinfection that has already proven its efficacy in preventing the transmission of airborne diseases such as measles and tuberculosis.Using published data from various sources it is shown that the SARS-CoV-2 virus, which causes COVID-19, is highly likely to be susceptible to UV damage while suspended in air irradiated by UV-C at levels that are acceptable and safe for upper-room applications. This is while humans are present in the room. Both the expected and worst-case scenarios are investigated to show the efficacy of the upper-room UV-C approach to reduce COVID-19 air transmission in a confined space with moderate but sufficient height. Discussion is given on the methods of analysis and the differences between virus susceptibility to UV-C when aerosolised or in liquid or on a surface.


PeerJ ◽  
2020 ◽  
Vol 8 ◽  
pp. e10196
Author(s):  
Clive B. Beggs ◽  
Eldad J. Avital

As the world’s economies come out of the lockdown imposed by the COVID-19 pandemic, there is an urgent need for technologies to mitigate COVID-19 transmission in confined spaces such as buildings. This feasibility study looks at one such technology, upper-room ultraviolet (UV) air disinfection, that can be safely used while humans are present in the room space, and which has already proven its efficacy as an intervention to inhibit the transmission of airborne diseases such as measles and tuberculosis. Using published data from various sources, it is shown that the SARS-CoV-2 virus, the causative agent of COVID-19, is highly likely to be susceptible to UV-C damage when suspended in air, with a UV susceptibility constant likely to be in the region 0.377–0.590 m2/J, similar to that for other aerosolised coronaviruses. As such, the UV-C flux required to disinfect the virus is expected to be acceptable and safe for upper-room applications. Through analysis of expected and worst-case scenarios, the efficacy of the upper-room UV-C approach for reducing COVID-19 transmission in confined spaces (with moderate but sufficient ceiling height) is demonstrated. Furthermore, it is shown that with SARS-CoV-2, it should be possible to achieve high equivalent air change rates using upper-room UV air disinfection, suggesting that the technology might be particularly applicable to poorly ventilated spaces.


2021 ◽  
Author(s):  
Cynthia Shih ◽  
Ruhi Pudipeddi ◽  
Arany Uthayakumar ◽  
Peter Washington

UNSTRUCTURED These are authors' responses to peer review of ms#24972.


2007 ◽  
Vol 73 (18) ◽  
pp. 5760-5766 ◽  
Author(s):  
James J. McDevitt ◽  
Ka Man Lai ◽  
Stephen N. Rudnick ◽  
E. Andres Houseman ◽  
Melvin W. First ◽  
...  

ABSTRACT Interest in airborne smallpox transmission has been renewed because of concerns regarding the potential use of smallpox virus as a biothreat agent. Air disinfection via upper-room 254-nm germicidal UV (UVC) light in public buildings may reduce the impact of primary agent releases, prevent secondary airborne transmission, and be effective prior to the time when public health authorities are aware of a smallpox outbreak. We characterized the susceptibility of vaccinia virus aerosols, as a surrogate for smallpox, to UVC light by using a benchtop, one-pass aerosol chamber. We evaluated virus susceptibility to UVC doses ranging from 0.1 to 3.2 J/m2, three relative humidity (RH) levels (20%, 60%, and 80%), and suspensions of virus in either water or synthetic respiratory fluid. Dose-response plots show that vaccinia virus susceptibility increased with decreasing RH. These plots also show a significant nonlinear component and a poor fit when using a first-order decay model but show a reasonable fit when we assume that virus susceptibility follows a log-normal distribution. The overall effects of RH (P < 0.0001) and the suspending medium (P = 0.014) were statistically significant. When controlling for the suspending medium, the RH remained a significant factor (P < 0.0001) and the effect of the suspending medium was significant overall (P < 0.0001) after controlling for RH. Virus susceptibility did not appear to be a function of virus particle size. This work provides an essential scientific basis for the design of effective upper-room UVC installations for the prevention of airborne infection transmission of smallpox virus by characterizing the susceptibility of an important orthopoxvirus to UVC exposure.