scholarly journals Theoretical Study on Isotope-Selective Dissociation of the Lithium Chloride Molecule Using a Designed Terahertz-Wave Field

Author(s):  
Akira Ichihara ◽  
Leo Matsuoka ◽  
Yuzuru Kurosaki ◽  
Keiichi Yokoyama
2010 ◽  
Vol 22 (11) ◽  
pp. 2653-2657
Author(s):  
徐世林 Xu Shilin ◽  
张会云 Zhang Huiyun ◽  
张玉萍 Zhang Yuping ◽  
王翠玲 Wang Cuiling

2018 ◽  
Vol 856 ◽  
pp. 850-869 ◽  
Author(s):  
Michelle H. DiBenedetto ◽  
Nicholas T. Ouellette

We report a theoretical study of the angular dynamics of small, non-inertial spheroidal particles in a linear wave field. We recover the observation recently reported by DiBenedetto et al. (J. Fluid Mech., vol. 837, 2018, pp. 320–340) that the orientation of these spheroids tends to a stable limit cycle consisting of a preferred value with a superimposed oscillation. We show that this behaviour is a consequence of finite wave amplitude and is the angular analogue of Stokes drift. We derive expressions for both the preferred orientation of the particles, which depends only on particle shape, and the amplitude of the oscillation about this preferred value, which additionally depends on the wave parameters and the depth of the particle in the water column.


1993 ◽  
Vol 47 (20) ◽  
pp. 13420-13431 ◽  
Author(s):  
Yuji Mochizuki ◽  
Toshikazu Takada ◽  
Akira Usui

2008 ◽  
Vol 123 (5) ◽  
pp. 3651-3651 ◽  
Author(s):  
Toshiyuki Kimura ◽  
Yoko Yamakata ◽  
Michiaki Katsumoto

2007 ◽  
Vol 3 (2) ◽  
pp. 152-156 ◽  
Author(s):  
Bo Sun ◽  
Jian-quan Yao ◽  
Bai-gang Zhang ◽  
Tie-li Zhang ◽  
Peng Wang

1991 ◽  
Vol 113 (1) ◽  
pp. 1-6 ◽  
Author(s):  
A. Ertas ◽  
E. E. Anderson ◽  
S. Kavasogullari

In order to analyze the performance of packed columns for dehumidification processes, calculation of the mass and heat transfer coefficients of the packing material used in the column is necessary. This paper is concerned with the interface transfer of heat and mass when air is brought into contact with the liquid desiccant mixtures. A theoretical study of heat and mass transfer analysis in an air-desiccant dehumidification contact system (packed column) employing liquid-desiccants, namely calcium chloride (CaCl2), lithium chloride (LiCl), and a new liquid-desiccant mixture (Cost-Effective Liquid Desiccant, CELD) consisting of 50 percent lithium chloride and 50 percent calcium chloride is studied. Mass and heat transfer coefficients for the gas and liquid phase, by use of 0.5-in., 1-in., 1.5-in., and 2-in. ceramic Rasching rings, are calculated. The findings for the three liquid desiccants are compared and discussed.


Sign in / Sign up

Export Citation Format

Share Document