scholarly journals Evaluation on Thermoluminescence Kinetic Parameters of Ge-Doped Cylindrical Fibre Dosimeter by Computerised Glow Curve Deconvolution Technique

Author(s):  
Muhammad S. A. Fadzil ◽  
Ung N. Min ◽  
Alawiah Ariffin ◽  
David A. Bradley ◽  
Noramaliza M. Noor
2018 ◽  
Vol 29 (18) ◽  
pp. 15732-15740 ◽  
Author(s):  
H. Durán-Muñoz ◽  
M. Hernández-Ortíz ◽  
C. Sifuentes-Gallardo ◽  
J. I. Galván-Tejeda ◽  
R. Sánchez-Zeferino ◽  
...  

2014 ◽  
Vol 1613 ◽  
pp. 127-131 ◽  
Author(s):  
Alejandro Ortiz-Morales ◽  
Ramón Gómez-Aguilar ◽  
Jaime Ortiz-Lopez ◽  
Epifanio Cruz-Zaragoza

ABSTRACTThe thermoluminiscent properties of MEH-PPV and MDMO-PPV conjugated polymers were studied in order to verify if they are suitable for use as TL dosimeter. The dose response that was analyzed cover the wide dose range 0.34-5.44 kGy. The measured glow curves show complex structures which were evaluated with kinetic parameters based on the MO (Mix Order) model together with the CGCD (Computerized Glow Curve Deconvolution) homemade program which is useful to understand the mechanisms responsible for TL emission.


2013 ◽  
Vol 28 (1) ◽  
pp. 45-51 ◽  
Author(s):  
Zdravko Vejnovic ◽  
Milos Pavlovic ◽  
Marina Kutin ◽  
Milorad Davidovic

A new method for fitting glow curves, described in a mixed order kinetics model, with Gauss-Lorentz function is shown. Theoretical expressions of the mixed order kinetics model are shown in a new way, so that the values of kinetic parameters can be obtained through the geometric parameters. When the model is described in this way it is possible to calculate precisely the kinetic parameters such as activation energy, pre-exponential factor and the factor a= n0/(h + n0). At the same time, obtained values of geometric parameters of the experimental curve, which is described with the Gauss-Lorentz function, can be used to estimate the kinetic model, in which thermoluminescence relaxation occurs. This gives a possibility of a new application of Gauss-Lorentz function to be used as a criterion for assessing model of relaxation, when it is not known in advance. The accuracy of fitting is studied, for the specific cases of computer simulated thermoluminescent curves with one peak.


2008 ◽  
Vol 205 (11) ◽  
pp. 2695-2703 ◽  
Author(s):  
Suchinder K. Sharma ◽  
Shreyas S. Pitale ◽  
M. Manzar Malik ◽  
R. N. Dubey ◽  
M. S. Qureshi

Author(s):  
Sang Duy Nguyen ◽  
Hung Van Tran ◽  
Hien Quoc Nguyen ◽  
Hung Van Nguyen

The kinetic parameters of thermoluminescene (TL) glow peaks of chilli powder irradiated by gamma rays with the different doses of 0, 4 and 8 kGy (i.e. activation energies (E), order of kinetics (b), trapping and recombination probability coefficients (R) and frequency factors (s)) have been determined and evaluated by glow curve deconvolution (GCD) method using the glow curve data to estimate lifetime of TL traps. The kinetic parameters of TL glow peaks are calculated by modeled first-, second-, generalorders of kinetics (GOK) thanking to the computer by using the R package TGCD. The results obtained as comparing the lifetime values of the three samples showed that the values of the 8 kGy irradiated-samples were the lowest whereas the 4 kGy irradiated-samples’value were greater than the non-irradiated samples’ one time.