Estimation of Exposure Time in Digital Radiography Applicable to Film Radiography

2021 ◽  
Vol 41 (5) ◽  
pp. 289-296
Author(s):  
Jin Wook Yang ◽  
Seo Ung Jeon ◽  
Kap Ho Cho ◽  
Mun Ho Nam
2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Evelyn Rute Carneiro Maciel ◽  
Eduarda Helena Leandro Nascimento ◽  
Hugo Gaêta-Araujo ◽  
Maria Luiza dos Anjos Pontual ◽  
Andrea dos Anjos Pontual ◽  
...  

Abstract Background This study aimed to investigate the effect of automatic exposure compensation (AEC) of intraoral radiographic systems on the gray values of dental tissues in images acquired with or without high-density material in the exposed region using different exposure times and kilovoltages. The influence of the distance of the high-density material was also investigated. Methods Radiographs from the molar region of two mandibles were obtained using the RVG 6100 and the Express systems, operating at 60 and 70 kV and 0.06, 0.10, and 0.16 s. Subsequently, a titanium implant was inserted in the premolar’s socket and other images were acquired. Using the ImageJ software, two regions of interest were determined on the enamel, coronary dentine, root dentine, and pulp of the first and second molars to obtain their gray values. Results In the RVG 6100, the implant did not affect the gray values (p > 0.05); the increase in kV decreased it in all tissues (p < 0.05), and the exposure time affected only the root dentine and pulp. In the Express, only enamel and coronary dentine values changed (p < 0.05), decreasing with the implant presence and/or with the increase in exposure factors. The distance of the implant did not affect the results (p > 0.05). Conclusions AEC’s performance varies between the radiographic systems. Its effect on the gray values depends not only on the presence or absence of high-density material but also on the kV and exposure time used.


Author(s):  
F. A. Heckman ◽  
E. Redman ◽  
J.E. Connolly

In our initial publication on this subject1) we reported results demonstrating that contrast is the most important factor in producing the high image quality required for reliable image analysis. We also listed the factors which enhance contrast in order of the experimentally determined magnitude of their effect. The two most powerful factors affecting image contrast attainable with sheet film are beam intensity and KV. At that time we had only qualitative evidence for the ranking of enhancing factors. Later we carried out the densitometric measurements which led to the results outlined below.Meaningful evaluations of the cause-effect relationships among the considerable number of variables in preparing EM negatives depend on doing things in a systematic way, varying only one parameter at a time. Unless otherwise noted, we adhered to the following procedure evolved during our comprehensive study:Philips EM-300; 30μ objective aperature; magnification 7000- 12000X, exposure time 1 second, anti-contamination device operating.


Author(s):  
K. Izui ◽  
T. Nishida ◽  
S. Furuno ◽  
H. Otsu ◽  
S. Kuwabara

Recently we have observed the structure images of silicon in the (110), (111) and (100) projection respectively, and then examined the optimum defocus and thickness ranges for the formation of such images on the basis of calculations of image contrasts using the n-slice theory. The present paper reports the effects of a chromatic aberration and a slight misorientation on the images, and also presents some applications of structure images of Si, Ge and MoS2 to the radiation damage studies.(1) Effect of a chromatic aberration and slight misorientation: There is an inevitable fluctuation in the amount of defocus due to a chromatic aberration originating from the fluctuations both in the energies of electrons and in the magnetic lens current. The actual image is a results of superposition of those fluctuated images during the exposure time. Assuming the Gaussian distribution for defocus, Δf around the optimum defocus value Δf0, the intensity distribution, I(x,y) in the image formed by this fluctuation is given by


Sign in / Sign up

Export Citation Format

Share Document