scholarly journals Impact of Simulated Gastric Acid on Surface Roughness and Frictional Resistance of Orthodontic Archwires: An In vitro Study

Author(s):  
Laila Baidas ◽  
Huda Alkawari ◽  
Nada Alshihah ◽  
Ghaida Almashaan ◽  
Haya Alwaalan

Introduction: Acid regurgitation caused by gastro-oesophageal reflux disease can lead to decreases in intraoral pH below the critical pH for orthodontic appliances. Exposure of brackets and archwires to such acidic environments causes changes in the surface properties that affect the frictional forces generated during orthodontic sliding mechanics and reduce the clinical efficacy of the wires. Aim: This in vitro study aimed to determine the effects of simulated gastric acid with pH 1.2 and pH 4 on the surface topography, surface roughness, and frictional resistance properties of different types of orthodontic archwires. Materials and Methods: A comparative in vitro study evaluated a total of 135 samples of three commercially available archwires: Stainless Steel (SS), nickel titanium, and beta-titanium (n=45/group). Each archwire was divided into three subgroups (n=15) according to different pH solutions: distilled water (control; pH 6.7), pH 4, and pH 1.2. The samples in the two acidic pH subgroups were immersed in the respective solution for two minutes, rinsed with distilled water, and stored in distilled water at 37°C. The procedure was repeated 6 times a day for nine days with 24-hours interval in between each cycle. The surface topography of the wires was examined by scanning electron microscopy, while the surface roughness was inspected by noncontact surface profilometry. Finally, the frictional resistance was measured by a universal testing machine. One-way ANOVA and a Tukey’s post-hoc test were used for analysis, with values of p≤0.05 considered significant. Results: The results showed an increase in surface roughness of the SS (p<0.001) and beta-titanium (p=0.003) wires as the acidity of the solution increased. The SS wires showed the lowest frictional resistance in pH 1.2 solution among the wires used (p=0.005). No correlation was found between surface roughness and frictional resistance in this study. Conclusion: Increased acidity condition significantly affects the surface roughness of beta-titanium and SS wires, and has no effect on the frictional behaviour of the orthodontic wires expects in the SS wires. Thus, because the surface properties of the archwires can be affected by acidity in the oral cavity, it is recommended to change the orthodontic wires regularly throughout orthodontic treatment, especially in patients with gastro-oesophageal reflux disease.

2020 ◽  
Vol 18 (3) ◽  
pp. 555-560
Author(s):  
Flávio Mendonça Copello ◽  
Lincoln Issamu Nojima ◽  
Margareth Maria Gomes Souza ◽  
Matheus Melo Pithon ◽  
Antônio Carlos Oliveira Ruellas ◽  
...  

2014 ◽  
Vol 60 (5) ◽  
pp. 200-203
Author(s):  
Andreea Borş ◽  
Cristina Molnar-Varlam ◽  
Melinda Székely

Abstract Objective: The aim of this in vitro study was to evaluate the influence of erosive conditions on the wear resistance of aesthetic direct restorative materials. Methods: Six dental filling materials were tested: two composites (Filtek Z550 and X-tra fil), two compomers (Dyract Extra and Twinky Star) and two glass ionomers (Ketac Molar and Fuji II LC). Twenty disks (10mm×2mm) of each material were prepared (n=120) and kept in artificial saliva at 37˚C for 24 hours. Specimens were cycled in acidic soft drink (Coca-Cola) 5×/day, for 5’, over 30 days. Initial surface roughness ISR (Ra-μm) and final surface roughness FSR were measured using a profilometer. The wear rate was calculated as difference of final minus the initial roughness (ΔSR=FSR-ISR). For statistical analysis t-test and one-way ANOVA test were used by GraphPad Prism version 5.03 statistical software. The level of significance was set at p<0.05. Results: The erosive wear rates (mean±SD, μm) after exposure to acidic beverage were: 0.30±0.03 (Ketac Molar), 0.28±0.04 (Fuji II LC), 0.27±0.00 (Filtek Z550), 0.23±0.01 (X-tra fil), 0.20±0.00 (Twinky Star) and 0.14±0.01 Dyract Extra, respectively. There were significant differences between the tested materials (p<0.05). Conclusions: Dental filling materials had different behaviour under the same erosive condition, however all investigated aesthetic restorative materials showed surface degradation. These findings suggest that erosive wear resistance of tooth coloured restoratives could influence their longevity in intraoral acidic conditions. Acknowledgements: The study was supported by the Internal Research Grant no. 5/30.01.2013 of the University of Medicine and Pharmacy of Tirgu Mureş.


2021 ◽  
Vol 18 (1) ◽  
pp. 49
Author(s):  
Khushboo Goyal ◽  
SuparnaGanguly Saha ◽  
Anuj Bhardwaj ◽  
MainakKanti Saha ◽  
Kaustubh Bhapkar ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document