scholarly journals Measurement and Analysis of Radiofrequency Radiation Exposure Level from Different Mobile Base Transceiver Stations in Ajaokuta and Environs, Nigeria

2013 ◽  
Vol 3 (6) ◽  
pp. 17-21
Author(s):  
Ushie, P. O. Ushie, P. O.
2021 ◽  
Vol 2034 (1) ◽  
pp. 012014
Author(s):  
D B Annida ◽  
S A Oladoja ◽  
O M Oni ◽  
E L Isreal ◽  
O B Ajayi ◽  
...  

2013 ◽  
Vol 10 ◽  
pp. 89-92
Author(s):  
Uwe Reischl ◽  
Gang Sun ◽  
Qazaleh Bahramian ◽  
Zhu Qing Xue

Thermal manikin tests were performed on selected protective garments to assess their heat transfer properties during exposure to infrared heat radiation. Comparing a newly developed Infrared (IR) Heat Radiation attenuatuion vest with a standard winter jacket, it could be seen that that the IR Vest provided a thermal comfort benefit above a heat radiation exposure level of 150 Watts while the winter jacket provided a thermal benefit above a 450 Watt heat radiation exposure level. The study identified important temperature cross-over points which define the thermodynamic properties and also characterize the heat radiation attenuation and heat insulation properties of garments. The evaluation method is seen as a new design tool for optimizing garment comfort and safety.


Author(s):  
Walder de Jesús Canova García

Resumen El creciente número de estaciones base de telefonía móvil celular alrededor de sectores residenciales o tránsito de personas, causa preocupación en la comunidad sobre si la radiación de campos electromagnéticos puedan causar riesgos en la salud. Internacionalmente existen estándares que establecen límites a las diversas fuentes de campos electromagnéticos para garantizar que se minimizan los riesgos en la salud. Cada país adopta dentro de su legislación algún estándar o recomendación y exige su cumplimiento a los operadores de estaciones de telecomunicaciones, por ejemplo en Colombia rige el decreto 195 de 2005. El artículo presenta una evaluación, basados en mediciones técnicas en el 2010, para obtener los niveles de exposición a campos electromagnéticos generados por las antenas instaladas en las estaciones base de telefonía móvil. Luego aparece el procedimiento general de mediciones, donde incluye el plan ejecutorial de mediciones, la configuración de la instrumentación y la caracterización de los lugares y puntos de medición. Por último, los resultados medidos en algunos lugares, donde las antenas de transmisión cumplían con la normativa adoptada en Colombia. Palabras Clave: Exposición a campos Electromagnéticos, Estaciones base de Telefonía móvil celular, Mediciones de banda angosta.   Abstract The growth of installations of transmitting antennas on base stations surrounding residential spaces or person traffic causes concerns in the community, about whether the radiation of electromagnetic fields of transmitting antennas in mobile base station can generate health risk. Over the world, there are standards that establish maximum levels permitted to different electromagnetic field sources to accomplish security ranges for health risks. Each country adopts in their legislation some international standard and requires to telecommunication operators stations for its compliance. In Colombian, the decree 195 of 2005 is still valid. This article shows an assessment, based on technical measurements developed in 2010, to acquire the electromagnetic field exposure levels generated by transmitting antennas installed on Mobile Base Station. This assessment includes the measurement system procedure: plan of measurement, instrumental configuration, and characterization of measurement places. Finally, here presents the measured results in some places, which exposure levels satisfied the adopted legislation in Colombia. Keywords: Electromagnetic Field Exposure, Mobile Base Stations, Narrowband Measurement.


2018 ◽  
Vol 63 (No. 11) ◽  
pp. 527-531
Author(s):  
S. Sung ◽  
S. Lim ◽  
K. Min ◽  
Y. Jung ◽  
Y. Cho ◽  
...  

The purpose of the current study was to investigate the radiation exposure level of surgeons performing C-arm guided small animal orthopaedic surgery using thermoluminescent dosimeters located inside and outside personnel shielding devices at major body parts. A prospective study was conducted to measure the radiation exposure dose of individuals in three positions (first assistant, operating surgeon and anaesthesiologist) using thermoluminescent dosimeters placed inside and outside protective devices. The lead equivalent protective devices included panorama mask, thyroid shield, apron and arm shield placed at five anatomic sites (eye, thyroid, breast, gonad and hand). Radiation exposure was measured during 12 surgical procedures with mean kVp of 51 and mean mAs of 1.6. The equivalent doses for thyroid, breast and gonad (outside/inside in mSv) were 1.75/0.58, 2.01/0.13 and 3.03/0.11, respectively, for the first assistant and 1.69/1.46, 4.82/0.35 and 5.25/0.22 for the operating surgeon. The dose of eye, thyroid, breast, gonad and arm for the anaesthesiologist were 0.61/0.51, 0.35/0.3, 0.67/0.34, 0.72/0.29 and 0.62/0.35, respectively. The exposure dose to gonads outside the lead protection showed the highest values in all participants. With lead protection, there was a significant reduction in the exposure dose to the gonads (first assistant, 96%; operating surgeon, 96%; anaesthesiologist, 60%). These results suggest that a radiation shield is essential in veterinary surgery with C-arms, particularly for gonad protection. In addition, these results demonstrate that exposure dose decreases with increasing distance from the C-arm machine.


SICOT-J ◽  
2020 ◽  
Vol 6 ◽  
pp. 6
Author(s):  
Yuta Jinnai ◽  
Tomonori Baba ◽  
Xu Zhuang ◽  
Hiroki Tanabe ◽  
Sammy Banno ◽  
...  

Introduction: Intraoperative fluoroscopy can be easily used because patients are placed in the supine position during total hip arthroplasty via direct anterior approach (DAA-THA) to reduce complications. However, the cumulative level of radiation exposure by intraoperative fluoroscopy increases as the annual number of cases increases, increasing the risk of influencing the health of both the patients and medical workers. The objective of the study was to compare the radiation exposure time of DAA-THA with osteosynthesis and to determine if the level of radiation exposure exceeded safety limits. Material and methods: DAA-THA was performed in 313 patients between January 2016 and July 2018 and 60 patients with proximal femoral fracture were treated with osteosynthesis. The intraoperative fluoroscopy time was retrospectively surveyed and compared between these two groups. A total of eight surgeons operated DAA-THA employing the same procedure using a traction table. A total of nine surgeons operated osteosynthesis and fluoroscopy was appropriately used during reduction and implant insertion. Results: The mean operative time of DAA-THA was 103.3 min and that of osteosynthesis was 83.3 min, showing a significant difference (p < 0.05). The mean intraoperative fluoroscopy time was 0.83 min (SD ± 0.68) in DAA-THA and 8.91 min (SD ± 8.34) in osteosynthesis showing a significant difference (p < 0.05). Conclusions: The intraoperative exposure level was significantly lower and the fluoroscopy time was significantly shorter in DAA-THA than in osteosynthesis for proximal femoral fracture. It was clarified that the annual cumulative radiation exposure level in DAA-THA does not exceed the tissue dose limit.


2010 ◽  
Vol 1313 ◽  
pp. 232-241 ◽  
Author(s):  
Dhiraj Maskey ◽  
Minsoo Kim ◽  
Bijay Aryal ◽  
Jonu Pradhan ◽  
In-Young Choi ◽  
...  

Sign in / Sign up