plasma atomic emission
Recently Published Documents


TOTAL DOCUMENTS

2286
(FIVE YEARS 87)

H-INDEX

66
(FIVE YEARS 3)

2021 ◽  
Vol 11 (3) ◽  
pp. 242-257
Author(s):  
Vladimir Zaichick

Thyroid adenomas (TA) are benign tumors, but there is a 20% possibility of malignant transformation. The distinguishing between the TA and thyroid cancer (TC) is tricky, therefore new TA biomarkers are needed. Furthermore, the role of chemical elements (ChE) in etiology and pathogenesis of TA is unclear. The aim of this exploratory study was to evaluate whether significant changes in the thyroid tissue levels of twenty chemical elements (ChE) Al, B, Ba, Br, Ca, Cl, Cu, Fe, I, K, Li, Mg, Mn, Na, P, S, Si, Sr, V, and Zn exist in the adenomatous transformed thyroid. Thyroid tissue levels of twenty ChE were prospectively evaluated in 19 patients with TA and 105 healthy inhabitants. Measurements were performed using a combination of non-destructive and destructive methods: instrumental neutron activation analysis and inductively coupled plasma atomic emission spectrometry, respectively. Tissue samples were divided into two portions. One was used for morphological study while the other was intended for ChE analysis. It was found that contents of of Al, B, Br, Cl, Cu, Na, and Zn are significantly higher whereas the levels of I some lower. in TA than in normal tissues. It was supposed that the changes in levels Al, B, Br, Cl, Cu, I, Na, and Zn in thyroid tissue can be used as TA markers.


Molecules ◽  
2021 ◽  
Vol 26 (11) ◽  
pp. 3130
Author(s):  
Hardoko I. Qudus ◽  
Purwadi Purwadi ◽  
Iis Holilah ◽  
Sutopo Hadi

This research aimed at developing an analysis method, which was optimized and validated to determine the content of mercury in skin lightening cream discovered in the market in Bandar Lampung, Indonesia, through the use of microwave plasma atomic emission spectroscopy (MP-AES). The optimization on the analysis method was conducted on pump rate, viewing position, and reductant concentration in order to obtain the highest mercury emission intensity, while the solution stability was optimized to know the stability of mercury in the solution. The result showed that the method developed had precision with a relative standard deviation of 2.67%, recovery value of 92.78%, and linearity with an r value of 0.993, respectively. The sensitivity of the instrument detection had a limit of analysis method detection and quantification of 0.59 and 1.98 µg/L, respectively. The results of the test of the lightening cream (8 of 16 samples) positively contained mercury in the range of 422.61–44,960.79 ng/g. Therefore the method of analysis developed may be used for routine analysis of chemicals in any cosmetics products.


Sign in / Sign up

Export Citation Format

Share Document