plus fraction
Recently Published Documents


TOTAL DOCUMENTS

30
(FIVE YEARS 4)

H-INDEX

7
(FIVE YEARS 0)

2021 ◽  
Author(s):  
Arwa Mawlod ◽  
Afzal Memon ◽  
John Nighswander

Abstract Objectives/Scope: Oil and gas operators use a variety of reservoir engineering workflows in addition to the reservoir, production, and surface facility simulation tools to quantify reserves and complete field development planning activities. Reservoir fluid property data and models are fundamental input to all these workflows. Thus, it is important to understand the propagation of uncertainty in these various workflows arising from laboratory fluid property measured data and corresponding model uncertainty. The first step in understanding the impact of laboratory data uncertainty was to measure it, and as result, ADNOC Onshore undertook a detailed study to assess the performance of four selected reservoir fluid laboratories. The selected laboratories were evaluated using a blind round-robin study on stock tank liquid density and molar mass measurements, reservoir fluid flashed gas and flashed liquid C30+ reservoir composition gas chromatography measurements, and Constant Mass Expansion (CME) Pressure-Volume-Temperature (PVT) measurements using a variety of selected reservoir and pure components test fluids. Upon completion of the analytical study and establishing a range of measurement uncertainty, a sensitivity analysis study was completed using an equation of state (EoS) model to study the impact of reservoir fluid composition and molecular weight measurement uncertainty on EoS model predictions. Methods, Procedures, Process: A blind round test was designed and administered to assess the performance of the four laboratories. Strict confidentiality was maintained to conceal the identity of samples through blind test protocols. The round-robin tests were also witnessed by the researchers. The EoS sensitivity study was completed using the Peng Robinson EoS and a commercially available software package. Results, Observations, Conclusions: The results of the fully blind reservoir fluid laboratory tests along with the statistical analysis of uncertainties will be presented in this paper. One of the laboratories had a systemic deviation in the measured plus fraction composition on black oil reference standard samples. The plus fraction concentration is typically the largest weight percent component in black oil systems and, along with the plus fraction molar mass, plays a crucial role in establishing the mole percent overall reservoir fluid compositions. Another laboratory had systemic issues related to chromatogram component integration errors that resulted in inconsistent carbon number concentration trends for various components. All laboratories failed to produce consistent molecular weight measurements for the reference samples. Finally, one laboratory had a relative deviation for P-V measurements that were significantly outside the acceptable range. The EoS sensitivity study demonstrates that the fluid composition and stock tank oil molar mass measurements have a significant impact on EoS model predictions and hence the reservoir/production models input when all other parameters are fixed. Novel/Additive Information: To the best of our knowledge, this is the first time such an extensive and fully blind round-robin test of commercial reservoir fluid characterization laboratories has been completed and published in the open literature. The industry should greatly benefit from this first-of-its-kind blind round-robin dataset being made available to all. The study provides the basis, protocols, expectations, and recommendations for such independent round-robin testing for fluid characterization laboratories on a broader scale.


2019 ◽  
Vol 97 (10) ◽  
pp. 2752-2764
Author(s):  
Sajjad Foroughi ◽  
Davood Khoozan ◽  
Saeid Jamshidi

2018 ◽  
Vol 7 (1) ◽  
pp. 1-10
Author(s):  
Steven Chandra

Characterizing heptanes plus fraction in PVT analysis has been a complex problem since its first inception. In this publication, the author is reviewing available mathematical functions employed for this task, whilst pointing out advantages and weaknesses for each of them and proposing a new method that is capable of complex characterization. This publication addresses a new method that is capable of accurately characterize heptane plus fraction especially in discontinued areas where errors could leap up to 40%. The author modifies natural logarithmic function to be used as an accommodation to discontinuities. The modified distribution provides better accuracy in modeling the discontinuities as a straight-line function, making them ideal for real gas condensate composition characterization. The new method is tested against several test data used by previous researchers, and applied to 3 sets of field data. The results have shown that this new method is capable of lowering CPU requirement whilst making better accuracy for all test data.


2018 ◽  
Vol 32 (2) ◽  
pp. 1624-1633 ◽  
Author(s):  
Victor B. Regueira ◽  
Verônica J. Pereira ◽  
Gloria M. N. Costa ◽  
Silvio A. B. Vieira de Melo

2014 ◽  
Vol 21 ◽  
pp. 1-9 ◽  
Author(s):  
Maryam Ghasemi ◽  
Ehsan Sedarat ◽  
Shahab Gerami ◽  
Shima Ebrahimzadeh ◽  
Mohammad Ali Emadi

2013 ◽  
Vol 8 (6) ◽  
pp. 819-829 ◽  
Author(s):  
Wei Wang ◽  
Jimiao Duan ◽  
Huishu Liu ◽  
Siqi Zhang ◽  
Jing Gong

Sign in / Sign up

Export Citation Format

Share Document