Abstract The conventional multi-frequency heterodyne method is one of the most widely used methods in non-contact 3D measurement. However, it needs to project different phase-shifting patterns with different frequencies, so a large number of patterns are required. For most conventional methods, the fringe period number of the projected patterns is usually small due to its limited noise tolerance, though the larger fringe period number always means higher accuracy. We propose a two-step phase-shifting demodulation algorithm based on intensity-gradient. In this method, only two patterns for each frequency are required. With the intensity-gradient of the two patterns, we obtain the wrapped phase of each frequency. Next, the absolute phase is retrieved from the three wrapped phases with the heterodyne algorithm. Because only two patterns are required for each frequency, the proposed method is more robust and has higher measuring speed compared with the traditional 3-frequency 4-step heterodyne method. Simulations and experiments prove the feasibility and effectiveness of the method, and demonstrate that the proposed method extends the noise tolerance and achieves high-precision with only a half of the patterns required by the traditional 3-frequency 4-step method.


2021 ◽  
Author(s):  
Jing Gao ◽  
Dongdong Jiao ◽  
Jie Liu ◽  
Xue Deng ◽  
ruifang Dong ◽  
...  

2021 ◽  
Author(s):  
Tawichai Premgamone ◽  
Jan Kortenbruck ◽  
Egon Ortjohann ◽  
Andreas Schmelter ◽  
Daniel Holtschulte ◽  
...  

Photonics ◽  
2021 ◽  
Vol 8 (5) ◽  
pp. 137
Author(s):  
Jing Gao ◽  
Dongdong Jiao ◽  
Xue Deng ◽  
Jie Liu ◽  
Linbo Zhang ◽  
...  

A polarization-insensitive recirculating delayed self-heterodyne method (PI-RDSHM) is proposed and demonstrated for the precise measurement of sub-kilohertz laser linewidths. By a unique combination of Faraday rotator mirrors (FRMs) in an interferometer, the polarization-induced fading is effectively reduced without any active polarization control. This passive polarization-insensitive operation is theoretically analyzed and experimentally verified. Benefited from the recirculating mechanism, a series of stable beat spectra with different delay times can be measured simultaneously without changing the length of delay fiber. Based on Voigt profile fitting of high-order beat spectra, the average Lorentzian linewidth of the laser is obtained. The PI-RDSHM has advantages of polarization insensitivity, high resolution, and less statistical error, providing an effective tool for accurate measurement of sub-kilohertz laser linewidth.


2021 ◽  
Vol 41 (7) ◽  
pp. 0712002
Author(s):  
高静 Gao Jing ◽  
焦东东 Jiao Dongdong ◽  
刘杰 Liu Jie ◽  
邓雪 Deng Xue ◽  
臧琦 Zang Qi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document