ringdown time
Recently Published Documents


TOTAL DOCUMENTS

4
(FIVE YEARS 2)

H-INDEX

2
(FIVE YEARS 1)

Sensors ◽  
2021 ◽  
Vol 21 (22) ◽  
pp. 7622
Author(s):  
Guosheng Ma ◽  
Yabai He ◽  
Bing Chen ◽  
Hao Deng ◽  
Ying Liu ◽  
...  

We developed a cavity ringdown spectrometer by utilizing a step-scanning and dithering method for matching laser wavelengths to optical resonances of an optical cavity. Our approach is capable of working with two and more lasers for quasi-simultaneous measurements of multiple gas species. The developed system was tested with two lasers operating around 1654 nm and 1658 nm for spectral detections of 12CH4 and its isotope 13CH4 in air, respectively. The ringdown time of the empty cavity was about 340 µs. The achieved high detection sensitivity of a noise-equivalent absorption coefficient was 2.8 × 10−11 cm−1 Hz−1/2 or 1 × 10−11 cm−1 by averaging for 30 s. The uncertainty of the high precision determination of δ13CH4 in air is about 1.3‰. Such a system will be useful for future applications such as environmental monitoring.


Sensors ◽  
2020 ◽  
Vol 20 (3) ◽  
pp. 585 ◽  
Author(s):  
Zhen Wang ◽  
Yanjun Du ◽  
Yanjun Ding ◽  
Zhimin Peng

A wide-range, calibration-free tunable diode laser spectrometer is established by combining wavelength modulation and direct absorption spectroscopy (WM-DAS) with continuous wave cavity ringdown spectroscopy (CW-CRDS). This spectrometer combines the benefits of absolute concentration measurements, wide range, and high speed, using WM-DAS with enhanced noise reduction in CW-CRDS. The accurate baseline ringdown time, τ0, is calculated by the absorption peak (measured by WM-DAS) and the ringdown time containing gas absorption information (measured by CW-CRDS at the center wavelength of the spectral line). The gas concentration is obtained without measuring τ0 in real time, thus, greatly improving the measuring speed. A WM-DAS/CW-CRDS spectrometer at 1.57 μm for CO detection was assembled for experimental validation of the multiplexing scheme over a concentration ranging from 4 ppm to 1.09% (0.1 MPa, 298 K). The measured concentration of CO at 6374.406 cm−1 shows that the dynamic range of this tunable diode laser absorption spectrometer is extendable up to five orders of magnitude and the corresponding precision is improved. The measurement speed of this spectrometer can extend up to 10 ms, and the detection limit can reach 35 ppb within 25 s.


Sign in / Sign up

Export Citation Format

Share Document