optical density measurement
Recently Published Documents


TOTAL DOCUMENTS

25
(FIVE YEARS 4)

H-INDEX

7
(FIVE YEARS 0)

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Danqing Li ◽  
Shuai Chen ◽  
Ke Zhang ◽  
Nan Gao ◽  
Miao Zhang ◽  
...  

AbstractSilver-based antibacterial agents have obtained wide attention due to the fact that bacteria in the environment is ubiquitous, which has become one of the most difficult problems for human health. However, the antibacterial mechanism and process are still inconclusive. Here, Ag2O nanoparticles (NPs) with uniform spherical morphology and small size (around 30 nm) were prepared. The as-prepared Ag2O NPs induced high antibacterial activity (100% inhibition ratio) against E. coli. A two-step antibacterial process was proposed and confirmed, which divided into inhibition and sterilization steps. The optical density measurement, malondialdehyde concentration detection, morphologic imaging with electronic microscopy and Fourier transform infrared spectroscopic analysis unveiled the interaction of Ag2O NPs with E. coli, which verified the inhibition–sterilization process we proposed.


Author(s):  
Oladotun A. Ojo ◽  
Peter A. Oluwafisoye ◽  
Charles O. Chime

The sensitivity of radiographic films is an important factor to the clarity and accuracy of X-ray exposure to patients during treatment or diagnostic periods. It is therefore important to do a thorough analysis of the sensitivity of the radiographic film before and after exposure to enhance the Quality Assurance (QA) and the Quality Control (QC), of the exposure procedures. The optical densities (OD) of each film was measured, with a densitometer model MA 5336, made by GAMMEX. These values were then converted to the absorbed dose (X mGy), which is the amount of dose absorbed by each patient. The optical density versus the dose curve, followed the expected pattern, showing a good prediction from the General model, that the films employed in the exposures were of good quality and standard. Hence the optical density versus dose sensitometric curves depicts the outcome of the various films sensitivity after an exposure to the X-ray radiation through the patients.


Retina ◽  
2016 ◽  
Vol 36 (7) ◽  
pp. 1381-1387 ◽  
Author(s):  
Qi Sheng You ◽  
Dirk-Uwe G. Bartsch ◽  
Mark Espina ◽  
Mostafa Alam ◽  
Natalia Camacho ◽  
...  

2016 ◽  
Vol 16 (4) ◽  
pp. 197-200
Author(s):  
E.N. Eskina ◽  
◽  
E.A. Egorov ◽  
A.V. Belogurova ◽  
А.А. Gvetadze ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document