controlled islanding
Recently Published Documents


TOTAL DOCUMENTS

147
(FIVE YEARS 52)

H-INDEX

18
(FIVE YEARS 4)

Author(s):  
N. Z. Saharuddin ◽  
I. Zainal Abidin ◽  
H. Mokhlis ◽  
E. F. Shair

<p>Power system-controlled islanding is one of the mitigation techniques taken to prevent blackouts during severe outage. The implementation of controlled islanding will lead to the formation of few islands, that can operate as a stand-alone island. However, some of these islands may not be balanced in terms of generation and load after the islanding execution. Therefore, a good load shedding scheme is required to meet the power balance criterion so that it can operate as a balanced stand-alone island. Thus, this paper developed a load shedding scheme-based metaheuristics technique namely modified discrete evolutionary programming (MDEP) technique to determine the optimal amount of load to be shed in order to produce balanced stand-alone islands. The developed load shedding scheme is evaluated and validated with two other load shedding techniques which are conventional EP and exhaustive search techniques. The IEEE 30-bus and 39-bus test systems were utilized for this purpose. The results proves that the load shedding based MDEP technique produces the optimal amount of loads to be shed with shortest computational time as compared with the conventional EP and exhaustive search techniques.</p>


Author(s):  
Mariano Dominguez Librandi ◽  
Daniel Stenzel ◽  
Thomas Wurl ◽  
Dominic Hewes ◽  
Lorenz Viernstein ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2790
Author(s):  
Jovancho Grozdanovski ◽  
Rafael Mihalic ◽  
Urban Rudez

It is expected that a coordinated operation of several system integrity protection schemes will become a necessity in the future. This research represents an innovative strategy for coordinating under-frequency load shedding and intentional controlled islanding schemes for improving electric power system stability and resilience. In the great majority of real-world cases, both approaches follow conventional tactics, i.e., disconnecting a fixed number of feeders at predefined frequency thresholds and isolating a predefined area of a power system regardless of the actual conditions. Under the newly arisen network conditions in which weather-dependent distributed energy sources introduce a significant level of intermittency, conventional approaches need to be upgraded in order to retain a high level of power system operation security. In this paper, a mixed-integer linear programming approach is used to adjust the island size, including/excluding additional substations according to the available amount of generation in the region. The fine-tuning of the power rebalancing is achieved by potentially blocking selected load shedding stages. This minimizes the power imbalance of the newly formed islands, which helps to reduce the number of partial or even total blackouts and also accelerates the power system’s restoration process. The optimization approach was tested on a generic IEEE 39-bus network and shows promising results along with the capability of coping with real-world applications using wide-area monitoring systems as a source of real-time measurements. The results also indicated the importance of appropriate load modelling since both voltage and frequency dependence are recognized to have a significant effect on intentional controlled islanding.


2021 ◽  
pp. 231-250
Author(s):  
Luyao Niu ◽  
Dinuka Sahabandu ◽  
Andrew Clark ◽  
Radha Poovendran

Sign in / Sign up

Export Citation Format

Share Document