slit collimator
Recently Published Documents


TOTAL DOCUMENTS

25
(FIVE YEARS 2)

H-INDEX

6
(FIVE YEARS 0)

2019 ◽  
Vol 7 (2A) ◽  
Author(s):  
Alexandre França Velo ◽  
Alexandre Gimenes Alvarez ◽  
Margarida Mizue Hamada ◽  
Carlos Henrique De Mesquita

The greatest impact of the computed tomography (CT) applications currently occurs in medicine. In industry there is much interest of using CT in order to know the interior of: (i) industrial objects; (ii) machines and their means of production. The purpose of this tomography is to: (a) control the quality of the final product and (b) optimize production and analyze the quality of the means of production. An instant non-scanning tomography system is being developed at the IPEN. This tomography comprised different collimators was simulated with Monte Carlo using the MCNP4C. The image quality was evaluated with Matlab® 2013b analyzing the contrast to noise (CNR), root mean square ratio (RMSE), signal to noise ratio (SNR) and the spatial resolution by the Modulation Transfer Function (MTF(f)), to identify which collimator fits better to the tomography in development. It was simulated three situations; (i) with no collimator; (ii) ø 25x 50 mm2 cylindrical collimator with a septum of ø5.0 x 50 mm2; (iii) ø25 x 50 mm2 cylindrical collimator with a slit septum of 24 x 5.0 x 50 mm3. RMSE values for no collimator presented better results. CNR showed that no collimator and slit collimator reaches the same CNR values, but no collimator decreases more than the slit collimator as the number of iteration rises. The hole collimator reaches a higher CNR value, however decreases more than the others. The spatial resolution with no collimator and slit collimator were around 31.9 mm, and for the hole collimator was around 20 mm


2018 ◽  
Vol 61 (2) ◽  
pp. 192-197 ◽  
Author(s):  
V. B. Sorokin ◽  
A. S. Lutsenko ◽  
V. G. Gentselman

2018 ◽  
Vol 170 ◽  
pp. 06005 ◽  
Author(s):  
V.E. Stepanov ◽  
A.G. Volkovich ◽  
V.N. Potapov ◽  
I.A. Semin ◽  
A.V. Stepanov ◽  
...  

From 2011 in the NRC "Kurchatov Institute" carry out the dismantling of the MR multiloop research reactor. Now the reactor and all technological equipment in the premises of the reactor were dismantled. Now the measurements of radioactive contamination in the reactor premises are made. The most contaminated parts of premises - floor and the ground beneath it. To measure the distribution of specific activity in the ground the CdZnTe detector (volume 500MM3) was used. Detector placed in a lead shielding with a slit collimation hole. The upper part of shielding is made movable to close and open the slit of the collimator. At each point two measurements carried out: with open and closed collimator. The software for determination specific activity of radionuclides in ground was developed. The mathematical model of spectrometric system based on the Monte-Carlo method. Measurements of specific activity of ground were made. Using the results of measurements the thickness of the removed layer of ground and the amount of radioactive waste were calculated.


2017 ◽  
Vol 177 ◽  
pp. 225-232
Author(s):  
Jonas M.C. Nilsson ◽  
Robert R. Finck ◽  
Christopher L. Rääf

Sign in / Sign up

Export Citation Format

Share Document