swept source octa
Recently Published Documents


TOTAL DOCUMENTS

12
(FIVE YEARS 9)

H-INDEX

3
(FIVE YEARS 0)

2021 ◽  
pp. 112067212110285
Author(s):  
Manpreet Brar ◽  
Mansi Sharma ◽  
SPS Grewal ◽  
Dilraj Grewal ◽  
Mangat Ram Dogra

Purpose: To assess the ability of wide field Swept Source OCTA (SS-OCTA) imaging to detect morphological variations in Serpiginous Choroiditis (SC) and Serpiginous Like Choroiditis (SLC) in response to treatment and also analyze these findings quantitatively using Image J software. Methods: Retrospective observational case series of nine eyes with clinical diagnosis of active SC and SLC, who underwent SS-OCTA and fundus autofluorescence (FAF) imaging at baseline and each follow up visit till 6 months. Morphological analysis was done by two independent graders and quantitative analysis to measure the size and intensity of lesion was done using publicly available Image J software at baseline and each follow up visit. Design: Retrospective observational case series. Results: Using SS-OCTA, all the active lesions followed a characteristic healing pattern. Active lesions appear well defined hypo flow void patches and as healing progressed, lesion became more ill-defined and iso-hyper- intense. Significant increase in mean intensity of the lesion could be apparent after 1 and 6 month of treatment. There was reduction in the size of lesions during follow up however this difference was not statistically significant. Conclusion: SS-OCTA could be a useful noninvasive tool to study the treatment response in SC/SLC both morphologically as well as quantitatively. Quantitative parameters need to be designed in further research studies to aid in uniform management and follow up of uveitis cases.


2021 ◽  
Vol 52 (4) ◽  
pp. 232-235
Author(s):  
Meryem Filali Ansary ◽  
Francesca Amoroso ◽  
Raimondo Forte ◽  
Salomon Y. Cohen ◽  
Alexandra Miere ◽  
...  

2021 ◽  
Vol 21 ◽  
pp. 101018
Author(s):  
Gayathri C. Tummala ◽  
Zhongdi Chu ◽  
Jessica E. Weinstein ◽  
Ruikang K. Wang ◽  
Kathryn L. Pepple

2020 ◽  
pp. bjophthalmol-2020-317890
Author(s):  
Torcato Santos ◽  
Lewis H Warren ◽  
Ana Rita Santos ◽  
Inês Pereira Marques ◽  
Sophie Kubach ◽  
...  

PurposeTo test whether a single or composite set of parameters evaluated with optical coherence tomography angiography (OCTA), representing retinal capillary closure, can predict non-proliferative diabetic retinopathy (NPDR) staging according to the gold standard ETDRS grading scheme.Methods105 patients with diabetes, either without retinopathy or with different degrees of retinopathy (NPDR up to ETDRS grade 53), were prospectively evaluated using swept-source OCTA (SS-OCTA, PlexElite, Carl Zeiss Meditec) with 15×9 mm and 3×3 mm angiography protocols. Seven-field photographs of the fundus were obtained for ETDRS staging. Eyes from age-matched healthy subjects were also imaged as control.ResultsIn eyes of patients with type 2 diabetes without retinopathy or ETDRS levels 20 and 35, retinal capillary closure was in the macular area, with predominant alterations in the parafoveal retinal circulation (inner ring). Retinal capillary closure in ETDRS stages 43–53 becomes predominant in the retinal midperiphery with vessel density average values of 25.2±7.9 (p=0.001) in ETDRS 43 and 23.5±3.4 (p=0.001) in ETDRS 47–53, when evaluating extended areas of 15×9 protocol. Combination of acquisition protocols 3×3 mm and 15×9 mm, using SS-OCTA, allows discrimination between eyes with mild NPDR (ETDRS 10, 20, 35) and eyes with moderate-to-severe NPDR (ETDRS grades 43–53).ConclusionsRetinal capillary closure, quantified by SS-OCTA, can identify NPDR severity progression. It is located mainly in the perifoveal retinal capillary circulation in the initial stages of NPDR, whereas the retinal midperiphery is predominantly affected in moderate-to-severe NPDR.


2020 ◽  
pp. 112067212097835
Author(s):  
Marie-Benedicte Rougier ◽  
Sarra Gattoussi ◽  
Melanie Le-Goff ◽  
Jean Francois Korobelnik

Background: In non-arteritic anterior ischemic optic neuropathy (NAION), optical coherence tomography angiography (OCTA) shows changes in peripapillary vascularization. However, the presence of an optic disc edema may induce artifacts that prevent visualizing the peripapillary network. The aim of this study was to evaluate the peripapillary vascularization in acute NAION using swept-source OCTA algorithms allowing segmenting only the retinal nerve fiber layer (RNFL). Methods: Retrospective analysis of 15 eyes with acute NAION of 15 patients. The optic nerve head was imaged using swept-source OCTA. Morphological and quantitative analyzes were performed. The capillary flux index (CFI), defined as the total weighted area of perfused vasculature per unit area, and the capillary perfusion density (CPD), defined as the total area of perfused microvasculature per unit area, were quantified. Each NAION eye was compared to the unaffected fellow eye using a Wilcoxon test for matched samples. Results: After segmentation at the RNFL, the morphological analysis showed less vascular dropout and more vascular tortuosity than the analysis of a larger segmentation. The quantitative analysis showed that the mean CFI and the CFI in the four quadrants were significantly higher in NAION eyes compared to healthy eyes ( p = 0.0002 and p < 0.01). The mean CPD and the CFD in the inferior quadrant were lower in NAION eyes ( p = 0.03 and p = 0.0054, respectively). Discussion: The RNFL segmentation allowed better visualizing the peripapillary network because the edema related darkening was reduced. The increased CFI suggests an autoregulatory phenomenon to compensate the ischemic process at the ciliary vasculature.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Jimmy Hong ◽  
Mengyuan Ke ◽  
Bingyao Tan ◽  
Amanda Lau ◽  
Damon Wong ◽  
...  

AbstractWe assessed the inter-visit repeatability of 15 × 9-mm2 swept-source OCTA (SS-OCTA; PLEX Elite 9000, Carl Zeiss Meditec) metrics in 14 healthy participants. We analysed the perfusion density (PD) of large vessels, superficial capillary plexus (SCP), and deep capillary plexus (DCP) as well as choriocapillaris flow voids in 2 different regions: the macular region and peripheral region. Also, retinal plexus metrics were processed further using different filters (Hessian, Gabor and Bayesian) while choriocapillaris flow voids were calculated with 1 and 1.25 standard deviation (SD) thresholding algorithms. We found excellent repeatability in the perfusion densities of large vessels (ICC > 0.96). Perfusion densities varied with different filters in the macular region (SCP: 24.12–38.57% and DCP: 25.16–38.50%) and peripheral (SCP: 30.52–39.84% and DCP: 34.19–41.60%) regions. The ICCs were lower in the macular region compared to the peripheral region and lower for DCP than for SCP. For choriocapillaris flow voids, the 1.25 SD threshold resulted in fewer flow voids, while a good ICC (ICC > 0.81) was achieved using either threshold settings for flow void features in both regions. Our results suggest good repeatability of widefield SS-OCTA for the measurements of retinal perfusion density and choriocapillaris flow voids, but measurements from different filters should not be interchanged.


2020 ◽  
pp. bjophthalmol-2020-316930
Author(s):  
Marcus Ang ◽  
Kavya Devarajan ◽  
Anna CS Tan ◽  
Mengyuan Ke ◽  
Bingyao Tan ◽  
...  

PurposeTo compare anterior segment optical coherence tomography angiography (AS-OCTA) systems in delineating normal iris vessels and iris neovascularisation (NVI) in eyes with pigmented irides.MethodsProspective study from January 2019 to June 2019 of 10 consecutive patients with normal pigmented iris, had AS-OCTA scans with a described illumination technique, before using the same protocol in five eyes with NVI (clinical stages 1–3). All scans were sequentially performed using a spectral-domain OCTA (SD-OCTA), and a swept-source OCTA (SS-OCTA, Plex Elite 9000). Images were graded by two masked observers for visibility, artefacts and NVI characteristics. The main outcome measure was iris vessel density measurements comparing SS-OCTA and SD-OCTA systems.ResultsThe median age of subjects was 28 (20–35) years, and 50% were female. The paired mean difference of iris vessel density measurements was 11.7 (95% CI 14.7 to 8.1; p=0.002), SS-OCTA detecting more vessels than SD-OCTA. The inter-rater reliability for artefact score (κ=0.799, p<0.001) and visibility score (κ=0.722; p<0.001) were substantial. Both AS-OCTA systems were able to detect NVI vessels with a fair agreement (κ=0.588), with clearer NVI characteristics in stage 1/2 compared to stage 3 NVI (mean difference NVI score: 2.7±0.4, p=0.009).ConclusionThe SS-OCTA was better able to delineate iris vessels in normal pigmented irides compared to SD-OCTA. Both AS-OCTA systems identified NVI characteristics based on its atypical configuration or location, but further improvements are needed to allow for more accurate objective, serial quantification for clinical use.


2020 ◽  
Vol 51 (7) ◽  
pp. 407-412
Author(s):  
Filippos Vingopoulos ◽  
Ying Cui ◽  
Raviv Katz ◽  
Rongrong Le ◽  
Ying Zhu ◽  
...  

2020 ◽  
Vol 61 (5) ◽  
pp. 8
Author(s):  
Sonja G. Karst ◽  
Morgan Heisler ◽  
Julian Lo ◽  
Nathan Schuck ◽  
Abdollah Safari ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document