wide field
Recently Published Documents


TOTAL DOCUMENTS

6614
(FIVE YEARS 1686)

H-INDEX

108
(FIVE YEARS 16)

Author(s):  
Solmaz Abdolrahimzadeh ◽  
Martina Formisano ◽  
Carla Marani ◽  
Siavash Rahimi

AbstractHereditary haemorrhagic telangiectasia (HHT) or Osler-Rendu-Weber syndrome is a rare autosomal dominant disease, characterised by systemic angiodysplasia. Dysfunction of the signalling pathway of β transforming growth factor is the main cause of HHT principally owing to mutations of the genes encoding for endoglin (ENG) and activin A receptor type II-like 1 (ACVRL1). Clinical manifestations can range from mucocutaneous telangiectasia to organ arterio-venous malformations and recurrent epistaxis. The early clinical manifestations may sometimes be subtle, and diagnosis may be delayed. The main ophthalmic manifestations historically reported in HHT are haemorrhagic epiphora, and conjunctival telangiectasia present in 45–65% of cases, however, imaging with wide-field fluorescein angiography has recently shown peripheral retinal telangiectasia in 83% of patients. Optimal management of HHT requires both understanding of the clinical presentations and detection of early signs of disease. Advances in imaging methods in ophthalmology such as wide-field fluorescein angiography, spectral domain optical coherence tomography, and near infrared reflectance promise further insight into the ophthalmic signs of HHT towards improved diagnosis and early management of possible severe complications.


2022 ◽  
Vol 163 (2) ◽  
pp. 65
Author(s):  
T. Cassanelli ◽  
Calvin Leung ◽  
M. Rahman ◽  
K. Vanderlinde ◽  
J. Mena-Parra ◽  
...  

Abstract The Canadian Hydrogen Intensity Mapping Experiment (CHIME)/FRB experiment has detected thousands of fast radio bursts (FRBs) due to its sensitivity and wide field of view; however, its low angular resolution prevents it from localizing events to their host galaxies. Very long baseline interferometry (VLBI), triggered by FRB detections from CHIME/FRB will solve the challenge of localization for non-repeating events. Using a refurbished 10 m radio dish at the Algonquin Radio Observatory located in Ontario Canada, we developed a testbed for a VLBI experiment with a theoretical λ/D ≲ 30 mas. We provide an overview of the 10 m system and describe its refurbishment, the data acquisition, and a procedure for fringe fitting that simultaneously estimates the geometric delay used for localization and the dispersive delay from the ionosphere. Using single pulses from the Crab pulsar, we validate the system and localization procedure, and analyze the clock stability between sites, which is critical for coherently delay referencing an FRB event. We find a localization of ∼200 mas is possible with the performance of the current system (single-baseline). Furthermore, for sources with insufficient signal or restricted wideband to simultaneously measure both geometric and ionospheric delays, we show that the differential ionospheric contribution between the two sites must be measured to a precision of 1 × 10−8 pc cm−3 to provide a reasonable localization from a detection in the 400–800 MHz band. Finally we show detection of an FRB observed simultaneously in the CHIME and the Algonquin 10 m telescope, the first non-repeating FRB in this long baseline. This project serves as a testbed for the forthcoming CHIME/FRB Outriggers project.


Photonics ◽  
2022 ◽  
Vol 9 (1) ◽  
pp. 44
Author(s):  
Zhehan Song ◽  
Zhihai Xu ◽  
Jing Wang ◽  
Huajun Feng ◽  
Qi Li

Proper features matter for salient object detection. Existing methods mainly focus on designing a sophisticated structure to incorporate multi-level features and filter out cluttered features. We present the dual-branch feature fusion network (DBFFNet), a simple effective framework mainly composed of three modules: global information perception module, local information concatenation module and refinement fusion module. The local information of a salient object is extracted from the local information concatenation module. The global information perception module exploits the U-Net structure to transmit the global information layer by layer. By employing the refinement fusion module, our approach is able to refine features from two branches and detect salient objects with final details without any post-processing. Experiments on standard benchmarks demonstrate that our method outperforms almost all of the state-of-the-art methods in terms of accuracy, and achieves the best performance in terms of speed under fair settings. Moreover, we design a wide-field optical system and combine with DBFFNet to achieve salient object detection with large field of view.


2022 ◽  
Author(s):  
Junjie Yao ◽  
Xiaoyi Zhu ◽  
Qiang Huang ◽  
Anthony DiSpirito ◽  
Tri Vu ◽  
...  

Abstract High-speed high-resolution imaging of the whole-brain hemodynamics is urgently needed to facilitate the next level of neurovascular research. Image acquisition speed and image quality are crucial to visualizing real-time hemodynamics in complex brain vascular networks, and displaying fast pathophysiological dynamics on a micro and macro-level, enabling advances in current queries in neurovascular and brain metabolism research, including stroke, dementia and acute brain injury. Further, real-time oxygen saturation of hemoglobin (sO2) imaging to differentiate arteries from veins and capture fast-paced oxygen delivery dynamics is needed to solve pertinent questions in these fields and beyond. Here, we present a novel ultrafast functional photoacoustic microscopy (UFF-PAM) to image the whole-brain hemodynamics and oxygen delivery. UFF-PAM takes advantage of several key engineering innovations, including Raman-shifter-based dual-wavelength laser excitation, water-immersible 12-facet-polygon scanner, high-sensitivity ultrasound transducer, and deep-learning-based image upsampling. A volumetric imaging rate of 2 Hz has been achieved over a field of view (FOV) of 11× 7.5 × 1.5 mm3 with a high spatial resolution of ~10 µm. Using the UFF-PAM system, we have demonstrated proof-of-concept functional studies on the mouse brains in response to systemic hypoxia, sodium nitroprusside, and stroke. We observed the mouse brain’s fast morphological and functional changes over the entire cortex, including vasoconstriction, vasodilation, and deoxygenation. More interestingly, for the first time, under the whole-brain FOV and micro-vessel resolution, we captured the vasoconstriction and oxygenation change simultaneously in the spreading depolarization (SD) wave. Our work provides a great potential for fundamental brain research under various pathological and physiological conditions.


2022 ◽  
Author(s):  
Huanyu Sun ◽  
Shiling Wang ◽  
Xiaobo Hu ◽  
Hongjie Liu ◽  
Xiaoyan Zhou ◽  
...  

Abstract Surface defects (SDs) and subsurface defects (SSDs) are the key factors decreasing the laser damage threshold of optics. Due to the spatially stacked structure, accurately detecting and distinguishing them has become a major challenge. Herein a detection method for SDs and SSDs with multisensor image fusion is proposed. The optics is illuminated by a laser under dark field condition, and the defects are excited to generate scattering and fluorescence lights, which are received by two image sensors in a wide-field microscope. With the modified algorithms of image registration and feature-level fusion, different types of defects are identified and extracted from the scattering and fluorescence images. Experiments show that two imaging modes can be realized simultaneously by multisensor image fusion, and HF etching verifies that SDs and SSDs of polished optics can be accurately distinguished. This method provides a more targeted reference for the evaluation and control of the defects of optics, and exhibits potential in the application of material surface research.


2022 ◽  
Vol 5 (1) ◽  
Author(s):  
Nazar Oleksiievets ◽  
Yelena Sargsyan ◽  
Jan Christoph Thiele ◽  
Nikolaos Mougios ◽  
Shama Sograte-Idrissi ◽  
...  

AbstractDNA point accumulation for imaging in nanoscale topography (DNA-PAINT) is a powerful super-resolution technique highly suitable for multi-target (multiplexing) bio-imaging. However, multiplexed imaging of cells is still challenging due to the dense and sticky environment inside a cell. Here, we combine fluorescence lifetime imaging microscopy (FLIM) with DNA-PAINT and use the lifetime information as a multiplexing parameter for targets identification. In contrast to Exchange-PAINT, fluorescence lifetime PAINT (FL-PAINT) can image multiple targets simultaneously and does not require any fluid exchange, thus leaving the sample undisturbed and making the use of flow chambers/microfluidic systems unnecessary. We demonstrate the potential of FL-PAINT by simultaneous imaging of up to three targets in a cell using both wide-field FLIM and 3D time-resolved confocal laser scanning microscopy (CLSM). FL-PAINT can be readily combined with other existing techniques of multiplexed imaging and is therefore a perfect candidate for high-throughput multi-target bio-imaging.


2022 ◽  
Vol 163 (2) ◽  
pp. 47
Author(s):  
Hunter Brooks ◽  
J. Davy Kirkpatrick ◽  
Dan Caselden ◽  
Adam C. Schneider ◽  
Aaron M. Meisner ◽  
...  

Abstract We present the discovery of CWISE J052306.42−015355.4, which was found as a faint, significant proper-motion object (0.″52 ± 0.″08 yr−1) using machine-learning tools on the unWISE re-processing of time series images from the Wide-field Infrared Survey Explorer. Using the CatWISE2020 W1 and W2 magnitudes along with a J-band detection from the VISTA Hemisphere Survey, the location of CWISE J052306.42−015355.4 on the W1 − W2 versus J − W2 diagram best matches that of other known, or suspected, extreme T subdwarfs. As there is currently very little knowledge concerning extreme T subdwarfs we estimate a rough distance of ≤68 pc, which results in a tangential velocity of ≤167 km s−1, both of which are tentative. A measured parallax is greatly needed to test these values. We also estimate a metallicity of −1.5 < [M/H] < −0.5 using theoretical predictions.


Sign in / Sign up

Export Citation Format

Share Document