golden angle radial
Recently Published Documents


TOTAL DOCUMENTS

56
(FIVE YEARS 28)

H-INDEX

10
(FIVE YEARS 3)

2021 ◽  
Author(s):  
Merlijn C. E. Plas ◽  
Sophie Schmid ◽  
Maarten J. Versluis ◽  
Thomas W. Okell ◽  
Matthias J. P. Osch

2021 ◽  
Vol 75 ◽  
pp. 89-99
Author(s):  
Yu Y. Li ◽  
Pengyue Zhang ◽  
Shams Rashid ◽  
Yang J. Cheng ◽  
Wenhui Li ◽  
...  

Author(s):  
Andrea Tomppert ◽  
Wolfgang Wuest ◽  
Marco Wiesmueller ◽  
Rafael Heiss ◽  
Markus Kopp ◽  
...  

Abstract Objectives Conventional perfusion-weighted MRI sequences often provide poor spatial or temporal resolution. We aimed to overcome this problem in head and neck protocols using a golden-angle radial sparse parallel (GRASP) sequence. Methods We prospectively included 58 patients for examination on a 3.0-T MRI using a study protocol. GRASP (A) was applied to a volumetric interpolated breath-hold examination (VIBE) with 135 reconstructed pictures and high temporal (2.5 s) and spatial resolution (0.94 × 0.94 × 3.00 mm). Additional sequences of matching temporal resolution (B: 2.5 s, 1.88 × 1.88 × 3.00 mm), with a compromise between temporal and spatial resolution (C: 7.0 s, 1.30 × 1.30 × 3.00 mm) and with matching spatial resolution (D: 145 s, 0.94 × 0.94 × 3.00 mm), were subsequently without GRASP. Instant inline-image reconstructions (E) provided one additional series of averaged contrast information throughout the entire acquisition duration of A. Overall diagnostic image quality, edge sharpness and contrast of soft tissues, vessels and lesions were subjectively rated using 5-point Likert scales. Objective image quality was measured as contrast-to-noise ratio in D and E. Results Overall, the anatomic and pathologic image quality was substantially better with the GRASP sequence for the temporally (A/B/C, all p < 0.001) and spatially resolved comparisons (D/E, all p < 0.002 except lesion edge sharpness with p = 0.291). Image artefacts were also less likely to occur with GRASP. Differences in motion, aliasing and truncation were mainly significant, but pulsation and fat suppression were comparable. In addition, the contrast-to-noise ratio of E was significantly better than that of D (pD-E < 0.001). Conclusions High temporal and spatial resolution can be obtained synchronously using a GRASP-VIBE technique for perfusion evaluation in head and neck MRI. Key Points • Golden-angle radial sparse parallel (GRASP) sampling allows for temporally resolved dynamic acquisitions with a very high image quality. • Very low-contrast structures in the head and neck region can benefit from using the GRASP sequence. • Inline-image reconstruction of dynamic and static series from one single acquisition can replace the conventional combination of two acquisitions, thereby saving examination time.


2020 ◽  
Vol 70 ◽  
pp. 73-80
Author(s):  
T. Demerath ◽  
K. Blackham ◽  
C. Anastasopoulos ◽  
K.T. Block ◽  
B. Stieltjes ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document