intensity calculation
Recently Published Documents


TOTAL DOCUMENTS

71
(FIVE YEARS 5)

H-INDEX

10
(FIVE YEARS 1)

2019 ◽  
Vol 58 (31) ◽  
pp. 8638
Author(s):  
S. Chatterjee ◽  
V. C. Vani ◽  
Rezvan R. Haghighi ◽  
Ravinder K. Banyal

2019 ◽  
Vol 3 (2) ◽  
pp. 60
Author(s):  
Urip Nurwijayanto Prabowo ◽  
Ayu Fitri Amalia ◽  
Widodo Budhi

Watukumpul is located in Pemalang District, Central Java, which is adjacent to the fault seismotectonic line of Baribis fault in the north and subduction area of the Eurasian and Indies-Australian plates in the south. It makes Watukumpul often experiences an earthquake. This study aimed to map the peak ground acceleration calculated using the Kanai equation and earthquake intensity calculated using Wald equations in Watukumpul. This study used historical earthquake data occurred in 1988-April 2018 from the International Seismological Center and microtremor measurements of 33 points. Microtremor data were processed using the Horizontal to Vertical Spectral Ratio method and resulted the predominant period of study area ranged from 0.13 to 0.74 s. The results showed that the study area had a PGA value of 26.93 - 63.25 gal. The intensity calculation showed that the study area has the potential for earthquake damage with an III-IV MMI scale. Keywords: Kanai, Watukumpul, Intensity, Earthquake


2019 ◽  
Vol 145 (5) ◽  
pp. 3146-3153 ◽  
Author(s):  
Mylan R. Cook ◽  
Kelli F. Succo ◽  
Kent L. Gee ◽  
Scott D. Sommerfeldt ◽  
Tracianne B. Neilsen

Author(s):  
Jun Ming Lyu ◽  
X. L. Cheng ◽  
J. J. Yu ◽  
F. Li ◽  
X. L. Yu

2018 ◽  
Vol 27 (6) ◽  
pp. 067801
Author(s):  
Hong-Bo Zhang ◽  
Qing-Li Zhang ◽  
Xing Wang ◽  
Gui-Hua Sun ◽  
Xiao-Fei Wang ◽  
...  

2017 ◽  
Vol 751 ◽  
pp. 202-206
Author(s):  
Parinya Chakartnarodom ◽  
Nuntaporn Kongkajun ◽  
Edward A. Laitila

The aim of this work is to study the influence of x-ray diffractometer scanning parameters on the integrated intensity and full-width at half maximum (FWHM) of copper powder x-ray diffraction peaks by using statistical analysis methods. X-ray diffraction (XRD) analysis of the copper powder was accomplished using step scan mode with step sizes of 0.03o and 0.05o 2q, and preset time changes from 0.1-3.5 s. Integrated intensity of an x-ray peak was calculated by the numerical method. FWHM was measured as the width of Pearson VII model of the x-ray peak at the half-maximum intensity. The statistical analysis methods including linear regression and statistical hypothesis test were used to analyze the correlation between the preset time and the error on integrated intensity calculation, and the FWHM of a peak on the XRD pattern. The results from statistical analysis show that increasing the preset time from 0.1 s to 3.5 s does not affect the FWHM of an x-ray peak, but it reduces the relative error in integrated intensity calculation. Moreover, using the preset time greater than 1 s will minimize the relative error in integrated intensity calculation of an x-ray peak. While step size did not affect both the relative error in integrated intensity calculation or FWHM, the smaller step size would provide more data points for better accurate model of an x-ray peak.


2017 ◽  
Vol 45 (2) ◽  
pp. 236-242 ◽  
Author(s):  
O. Gumen ◽  
V. Dovhaliuk ◽  
Viktor Mileikovskyi ◽  
O. Lebedieva ◽  
V. Dziubenko

Sign in / Sign up

Export Citation Format

Share Document