Radiology - Open Journal
Latest Publications


TOTAL DOCUMENTS

37
(FIVE YEARS 0)

H-INDEX

2
(FIVE YEARS 0)

Published By Openventio Publishers

2473-0947

2020 ◽  
Vol 4 (2) ◽  
pp. 39-45
Author(s):  
Yati Hardiyanti ◽  
◽  
Thareq Barasabha ◽  
Choirul Anam ◽  
Novitrian Novitrian ◽  
...  

Purpose This study analysed the sensitivity of the field size from variations in the target volume dimensions, depth, and position. The variations in the target volume analysis were used to determine the width of the field size. Thus, the quality control of the radiation beam can be obtained. Materials and Methods The computed tomography (CT) image of the IBA Dose 1 type of water phantom consists of 350 slices. Variations in the dimension of the target volume were modelled in 10×10×10 cm3, 10×12×10 cm3 , 10.2×10×10.2 cm3, and 15×15×15 cm3. Beam parameters use one beam of irradiation on the central axis 0°, 6 MV energy, 100 cm source-skin distance (SSD), beamlet delta x, and y set to 0.1 cm. Dose distribution in the form of the XZ isodose curve and dose profile was used to observe the field size. Results In this study, the isodose curve was successfully displayed in the XZ isodose curve. The field size’s sensitivity has been successfully reviewed from variations of the target volume, depth, and position. The target X and Z direction analysis is used in determining the width and length of the field size. Conclusion The analysis related to the field size sensitivity study was obtained from a relatively valid calculation. The field size was evaluated with variations in depth of 1.5 cm, 5 cm, 10 cm, and variations in positions of 10 cm, 12 cm, 14 cm, 18 cm, and 20 cm. This study will be used as a reference to validate the distribution of computational environment for radiotherapy research (CERR) dose in the future. Thus, the accuracy of the dose calculation can be obtained.



2020 ◽  
Vol 4 (2) ◽  
pp. 30-38
Author(s):  
Theresa Lee ◽  
◽  
Euclid Seeram ◽  

Background Current image reconstruction techniques in computed tomography (CT) such as filtered back-projection (FBP) and iterative reconstruction (IR) have limited use in low-dose CT imaging due to poor image quality and reconstruction times not fit for clinical implementation. Hence, with the increasing need for radiation dose reductions in CT, the use of artificial intelligence (AI) in image reconstruction has been an area of growing interest. Aim The aim of this review is to examine the use of AI in CT image reconstruction and its effectiveness in enabling further dose reductions through improvements in image quality of low-dose CT images. Method A review of the literature from 2016 to 2020 was conducted using the databases Scopus, Ovid MEDLINE, and PubMed. A subsequent search of several well-known journals was performed to obtain additional information. After careful assessment, articles were excluded if they were not obtainable from the databases or not available in English. Results This review found that deep learning-based algorithms demonstrate promising results in improving the image quality of low-dose images through noise suppression, artefact reduction, and structure preservation in addition to optimising IR methods. Conclusion In conclusion, with the two AI-based CT systems currently in clinical use showing favourable benefits, it is expected that AI algorithms will continue to proliferate and enable significant dose reductions in CT imaging.



2020 ◽  
Vol 4 (2) ◽  
pp. 55-58
Author(s):  
Priscila F. Berganza ◽  
◽  
Maria D. Molina ◽  
María A. P. Dahinten ◽  
Mariela S. Ramos ◽  
...  

Endometrial hyperplasia is defined as the pathological condition caused by hyper plastic changes at the level of the glandular and stromal structures of the endometrium that are part of the lining of the endometrial cavity. Atypical endometrial hyperplasia can cause an essential problem because it is considered a precursor of endometrial cancer. The early diagnosis of precancerous endometrial lesions and the exclusion of pre-existing endometrial carcinomas are necessary for patients’ optimal management. The following is a case of a 50-year-old Guatemalan patient with a three-day history of vaginal bleeding. The transvaginal ultrasound reports endometrial thickening suggestive of endometrial hyperplasia. The diagnosis was confirmed with histology. The treatment offered was surgery without indicating any medication.



2020 ◽  
Vol 4 (1) ◽  
pp. 7-12
Author(s):  
Hanan S. Gewefel ◽  
◽  
Sophia Michelen ◽  
Bodour Salhia ◽  
Iman Ewais ◽  
...  


2020 ◽  
Vol 4 (1) ◽  
pp. 13-15
Author(s):  
Deepsha Agrawal ◽  
◽  
Athanasios Grivas ◽  
Ancy Joseph ◽  
◽  
...  


2020 ◽  
Vol 4 (1) ◽  
pp. 23-29
Author(s):  
Samantha Yew ◽  
◽  
Euclid Seeram ◽  


2020 ◽  
Vol 4 (1) ◽  
pp. 21-22
Author(s):  
Greg Martin ◽  




Sign in / Sign up

Export Citation Format

Share Document