Evaluation of Artificial Intelligence–Based Intraoperative Guidance Tools for Phacoemulsification Cataract Surgery

Author(s):  
Rogerio Garcia Nespolo ◽  
Darvin Yi ◽  
Emily Cole ◽  
Nita Valikodath ◽  
Cristian Luciano ◽  
...  
Author(s):  
Reinhard Angermann ◽  
Christoph Palme ◽  
Philipp Segnitz ◽  
Andreas Dimmer ◽  
Eduard Schmid ◽  
...  

Summary Background The aim of the present study was to describe surgically induced astigmatism (SIA) and the coupling effect after conventional phacoemulsification cataract surgery (CPS) in relation to the incisional axis. Material and methods A total of 42 patients were included in the retrospective case series study. Corneal topography was obtained for patients with significant cataract before and 6 weeks after CPS with a main clear corneal incision size of 2.4 mm. Patients were grouped according to the relationship of the incisional axis to the position of the steep axis into a steep incisional group and a flat incisional group. Results In total, 46 eyes were included in the study. While the steep incisional group showed an SIA of −0.15 D (± 0.35), the flat incisional group had a significantly higher SIA of 0.20 D (± 0.51) (p = 0.03). The coupling ratio (CR) in the steep incisional group was −0.38 (± 1.41) and in the flat incisional group it was 0.16 (± 0.97). Correspondingly, a coupling constant (CC) of −0.25 was found for group 1 and a CC of 0.0 for group 2. Conclusion Our results suggest that the location of the main incision should be decided with consideration of the corneal astigmatism in order to minimize the SIA. The CR helps to understand the effect of induced astigmatism and the change in spherical equivalent.


2020 ◽  
pp. 112067212098437
Author(s):  
Giulia Coco ◽  
Pierluca Cremonesi ◽  
Nardine Menassa ◽  
Luca Pagano ◽  
Kunal A Gadhvi ◽  
...  

Purpose: To investigate the effect of ultrasound level during phacoemulsification on pupil dynamics. Methods: Comparative retrospective study on patients who underwent routine cataract surgery at the Royal Liverpool University Hospital. Clinical parameters, anterior chamber measurements, axial length, surgeon grade, time of surgery, level of ultrasound used (cumulative dissipated energy, CDE), intra- and post-operative complications were collected. Pupil diameters were collected before and 4 ± 1 weeks after surgery in static scotopic, mesopic, photopic pupil conditions. Also, pupil dynamic measurements after luminous stimulus were recorded. Changes in static pupil diameters, relative dilation at 3.5 s after luminous stimulus, and time to reach 75% and 95% of maximum dilation were measured. Results: Forty-eight eyes of 24 patients (13 males) were included with a mean age of 73.1 ± 14.6 years. Mean CDE value was 18.11 ± 10.56. Mean scotopic pupil diameters decreased by 0.24 ± 0.48 mm ( p = 0.021) in the operated eye. Significant correlation was found between reduction in scotopic pupil diameter and CDE ( p = 0.05). A generalized linear model confirmed that the level of CDE was significantly associated with reduction in scotopic pupil diameter ( p = 0.026). Patients who underwent surgeries with lower CDE (0 < CDE ⩽ 10 and 10 < CDE ⩽ 20) did not experience significant changes in scotopic pupil diameter after surgery ( p = 0.28 and p = 0.79, respectively) as opposed to those with higher CDE (CDE > 20; p = 0.03). Conclusion: Phacoemulsification cataract surgery and the cumulative dissipated energy may be associated with changes in pupil behaviour.


2011 ◽  
Vol 11 (1) ◽  
Author(s):  
Marilita M Moschos ◽  
Irini P Chatziralli ◽  
Theodoros N Sergentanis

2017 ◽  
Vol 43 (8) ◽  
pp. 1031-1035 ◽  
Author(s):  
Amelia Lim Lay Suan ◽  
Jemaima Che Hamzah ◽  
Tan Soo Ken ◽  
Vanessa Naseem Mansurali