Surface Structures and Osteoblast Activity on Biomedical Polytetrafluoroethylene Treated by Long-Pulse, High-Frequency Oxygen Plasma Immersion Ion Implantation

2010 ◽  
Vol 12 (5) ◽  
pp. B163-B169 ◽  
Author(s):  
Liping Tong ◽  
Dixon T. K. Kwok ◽  
Huaiyu Wang ◽  
Lijun Wu ◽  
Paul K. Chu
Biomaterials ◽  
2010 ◽  
Vol 31 (3) ◽  
pp. 413-419 ◽  
Author(s):  
Huaiyu Wang ◽  
Dixon T.K. Kwok ◽  
Wei Wang ◽  
Zhengwei Wu ◽  
Liping Tong ◽  
...  

2019 ◽  
Vol 365 ◽  
pp. 173-178 ◽  
Author(s):  
Duen-Kai Shiau ◽  
Chih-Hsiung Yang ◽  
Ying-Sui Sun ◽  
Mei-Fang Wu ◽  
Haobo Pan ◽  
...  

1991 ◽  
Vol 223 ◽  
Author(s):  
C. A. Pico ◽  
X. Y. Qian ◽  
E. Jones ◽  
M. A. Lieberman ◽  
N. W. Cheung

ABSTRACTPlasma immersion ion implantation (PIII) has been applied to fabricate shallow p-n junction diodes and MOS test structures. BF3 ions created by an electron cyclotron resonance source were implanted into n-type Si(100) at an accelerating voltage of −2 kv. The implant doses ranged from 4 × 1014/cm2 to 4 × 1015/cm2. In some cases, the top layers of the Si(100) substrates were preamorphized by a 3 × 1015/cm2 to 1016/cm2 implant of SiF4 by PIII at −7.2 kV prior to the BF3 implant. The ideality factor exhibited in both non- and preamorphized samples during forward bias is 1.02 to 1.05. Reverse leakages were measured at 30 nA/cm2 at −5V. High frequency capacitance and high field breakdown measurements of the oxide test structures showed no significant damage to the oxide.


2014 ◽  
Vol 880 ◽  
pp. 155-160 ◽  
Author(s):  
Alexander Ryabchikov ◽  
Denis Sivin ◽  
Anna Ivanova (Bumagina) ◽  
Evgeniy Bolbasov ◽  
Natalya Daneikina

This paper is devoted to the studying of the dynamical changes in the density of aluminium microparticles (MPs) on the substrate surface made of stainless steel, immersed in vacuum arc plasma, at high-frequency short-pulse negative bias potential. It is shown experimentally that the density of aluminium MPs on the substrate surface is decreased dynamically by 3 orders when the treatment time is increased from 15 s to 3 min at the bias potential –2 kV. A possibility of the application of MPs unfiltered vacuum arc plasma for high-frequency short-pulse plasma immersion ion implantation to form the intermetallic layers is discussed.


Author(s):  
Paternoster Carlo ◽  
Marin De Andrade Let�cia ◽  
Monta�o-Machado Vanessa ◽  
Tolouei Ranna ◽  
Turgeon St�phane ◽  
...  

RSC Advances ◽  
2016 ◽  
Vol 6 (78) ◽  
pp. 74493-74499 ◽  
Author(s):  
S. Viswanathan ◽  
L. Mohan ◽  
Parthasarathi Bera ◽  
C. Anandan

Ni–Ti alloy has been implanted with oxygen ions by plasma immersion ion implantation. Ni–Ti–O nanotubes are formed by anodic oxidation of oxygen implanted Ni–Ti alloy.


Sign in / Sign up

Export Citation Format

Share Document