Effect of Electric Field on the Lubricating Performance of Ga‐Based Liquid Metal

2019 ◽  
Vol 6 (10) ◽  
pp. 1900028 ◽  
Author(s):  
Jie Guo ◽  
Jun Cheng ◽  
Hui Tan ◽  
Shengyu Zhu ◽  
Zhuhui Qiao ◽  
...  
Keyword(s):  
1993 ◽  
Vol 3 (8) ◽  
pp. 1201-1225 ◽  
Author(s):  
G. N�ron de Surgy ◽  
J.-P. Chabrerie ◽  
O. Denoux ◽  
J.-E. Wesfreid

Micromachines ◽  
2019 ◽  
Vol 10 (11) ◽  
pp. 769 ◽  
Author(s):  
Wang ◽  
Zhang ◽  
Gao ◽  
Wang ◽  
Deng ◽  
...  

This paper proposes a novel microdroplet generator based on the dielectrophoretic (DEP) force. Unlike the conventional continuous microfluidic droplet generator, this droplet generator is more like “invisible electric scissors”. It can cut the droplet off from the fluid matrix and modify droplets’ length precisely by controlling the electrodes’ length and position. These electrodes are made of liquid metal by injection. By applying a certain voltage on the liquid-metal electrodes, the electrodes generate an uneven electric field inside the main microfluidic channel. Then, the uneven electric field generates DEP force inside the fluid. The DEP force shears off part from the main matrix, in order to generate droplets. To reveal the mechanism, numerical simulations were performed to analyze the DEP force. A detailed experimental parametric study was also performed. Unlike the traditional droplet generators, the main separating force of this work is DEP force only, which can produce one droplet at a time in a more precise way.


Micromachines ◽  
2020 ◽  
Vol 11 (10) ◽  
pp. 935
Author(s):  
Ruining Huang ◽  
Ying Yi ◽  
Erlei Zhu ◽  
Xiaogang Xiong

Micro-electro-discharge machining (μEDM) plays a significant role in miniaturization. Complex electrode manufacturing and a high wear ratio are bottlenecks for μEDM and seriously restrict the manufacturing of microcomponents. To solve the electrode problems in traditional EDM, a µEDM method using liquid metal as the machining electrode was developed. Briefly, a liquid-metal tip was suspended at the end of a capillary nozzle and used as the discharge electrode for sparking the workpiece and removing workpiece material. During discharge, the liquid electrode was continuously supplied to the nozzle to eliminate the effects of liquid consumption on the erosion process. The forming process of a liquid-metal electrode tip and the influence of an applied external pressure and electric field on the electrode shape were theoretically analyzed. The effects of external pressure and electric field on the material removal rate (MRR), liquid-metal consumption rate (LMCR), and groove width were experimentally analyzed. Simulation results showed that the external pressure and electric field had a large influence on the electrode shape. Experimental results showed that the geometry and shape of the liquid-metal electrode could be controlled and constrained; furthermore, liquid consumption could be well compensated, which was very suitable for µEDM.


2022 ◽  
Author(s):  
Xu Meng ◽  
Z H Wang ◽  
Dengke Zhang

Abstract In the future application of nuclear fusion, the liquid metal flows are considered to be an attractive option of the first wall of the Tokamak which can effectively remove impurities and improve the confinement of plasma. Moreover, the flowing liquid metal can solve the problem of the corrosion of the solid first wall due to high thermal load and particle discharge. In the magnetic confinement fusion reactor, the liquid metal flow experiences strong magnetic and electric, fields from plasma. In the present paper, an experiment has been conducted to explore the influence of electric and magnetic fields on liquid metal flow. The direction of electric current is perpendicular to that of the magnetic field direction, and thus the Lorentz force is upward or downward. A laser profilometer (LP) based on the laser triangulation technique is used to measure the thickness of the liquid film of Galinstan. The phenomenon of the liquid column from the free surface is observed by the high-speed camera under various flow rates, intensities of magnetic field and electric field. Under a constant external magnetic field, the liquid column appears at the position of the incident current once the external current exceeds a critical value, which is inversely proportional to the magnetic field. The thickness of the flowing liquid film increases with the intensities of magnetic field, electric field, and Reynolds number. The thickness of the liquid film at the incident current position reaches a maximum value when the force is upward. The distribution of liquid metal in the channel presents a parabolic shape with high central and low marginal. Additionally, the splashing, i.e., the detachment of liquid metal is not observed in the present experiment, which suggests a higher critical current for splashing to occur.


2017 ◽  
Vol 19 (28) ◽  
pp. 18505-18513 ◽  
Author(s):  
M. F. Wang ◽  
M. J. Jin ◽  
X. J. Jin ◽  
S. G. Zuo

We systematically investigate the factors during movement through experiment and innovative modeling, which combine pertinent forces.


Sign in / Sign up

Export Citation Format

Share Document