Numerical analysis of steel double side joints with flush and extended end plate under accidental situation

ce/papers ◽  
2021 ◽  
Vol 4 (2-4) ◽  
pp. 77-84
Author(s):  
Kukla Damian ◽  
Kozłowski Aleksander ◽  
Siwowski Tomasz
2014 ◽  
Vol 578-579 ◽  
pp. 505-508
Author(s):  
Shao Qin Zhang ◽  
Lei Wu

In the present paper, we investigate the effect of a padding-plate on the behavior of extended end-plate semi-rigid connections. The numerical simulations were carried out for a standard extended end-plate connection joint without padding-plate and two connection joints with 4mm and 6mm thick padding-plates. The existing experimental results verified the validity of the numerical model. The numerical results have shown that a thin padding-plate will more or less decline the carrying load capacity of the connection joint but greatly improve the connect ductility. Filling a thin padding-plate in the end-plate connection is feasible and brings the forewarning function.


ce/papers ◽  
2019 ◽  
Vol 3 (5-6) ◽  
pp. 362-371
Author(s):  
Vanessa S. de Freitas ◽  
Luiz Carlos de Almeida ◽  
Leandro M. Trautwein

2012 ◽  
Vol 193-194 ◽  
pp. 1405-1413 ◽  
Author(s):  
Zhu Ling Yan ◽  
Bao Long Cui ◽  
Ke Zhang

This paper conducts analysis on beam-column extended end-plate semi-rigid connection joint concerning monotonic loading and cyclic loading of finite element through ANSYS program, mainly discussed the influence of parameters such as the form of end plate stiffening rib on anti-seismic performance of joint.


2011 ◽  
Vol 250-253 ◽  
pp. 1271-1274
Author(s):  
Saggaff Anis ◽  
M.Md. Tahir ◽  
Arizu Sulaiman ◽  
Poi Ngian Shek ◽  
Cher Siang Tan ◽  
...  

The objective of this paper is to present the behaviour of composite beam using Trapezoid Web Profiled (TWP) steel section by determining the moment resistance and the deflection of the beam with composite and non-composite connections. The TWP steel section is a built up section where the flange is of S355 steel section and the corrugated web of S275 steel section. Three full scales testing setting-up as sub-assemblage frame have been carried out. It was concluded that the use of composite connection and extended end-plate has reduced significantly the deflection and has significantly increased the loading capacity of composite beam.


2018 ◽  
Vol 763 ◽  
pp. 818-825 ◽  
Author(s):  
Roberto Tartaglia ◽  
Mario D'Aniello ◽  
Gian Andrea Rassati ◽  
James A. Swanson ◽  
Raffaele Landolfo

Extended stiffened end-plate connections are widely used in seismic area due to their good performance in terms of both resistance and ductility. The most of existing studies focused on the all-steel behavior of these joints, disregarding the composite action of the concrete slab that is generally disconnected. However, the presence of the concrete slab can have beneficial effects on the structural stiffness for both gravity and lateral loads. Hence, most of the building frames are usually designed considering steel-concrete composite solution. However, the slab can strongly influence the hierarchy between beam and column and the ductility of the joint. In this paper the influence of composite deck on the response of extended stiffened end-plate joins has been investigated by means of finite element analyses (FEAs). In particular, the following details have been investigated: (i) all steel joints without slab; (ii) steel joint with disconnected slab; (iii) composite joint.


Sign in / Sign up

Export Citation Format

Share Document