scholarly journals Modified strut and tie model of headed stud shear connectors in open trough profiled sheeting for predicting the post‐cracking load bearing resistance

ce/papers ◽  
2021 ◽  
Vol 4 (2-4) ◽  
pp. 627-634
Author(s):  
Valentino Vigneri ◽  
Christoph Odenbreit ◽  
Dennis Lam ◽  
François Hanus
2019 ◽  
Vol 12 (3) ◽  
pp. 184-190
Author(s):  
Valentino Vigneri ◽  
Christoph Odenbreit ◽  
Dennis Lam

2019 ◽  
Vol 17 (1) ◽  
Author(s):  
Panji Ginaya Taufik

Pile cap is a structure to distribute load from the upper structure to the sub structure. Often the planning of the pile cap is approached as a two way slab or beam with pile as restrain, by consider the bending and shear separately. As is the case with conventional methods that consider 1-way shear, 2-way shear, and bending separately. The strut and tie model can be used as an alternative method in designing a pile cap, by approaching the stress trajectory with the truss model. In this study, a pile cap will be designed using the conventional method and the strut and tie model, the pile cap with 3 pile cap and an eccentric load. Then the results are tested numerically using Abaqus to determine the difference in behavior. The main reinforcement results from the strut and tie model method are more evenly stressed than the conventional method, also the vertical load needed to achieve the main reinforcement yield stress strut and tie model (1100 kN) is greater than the conventional method (900 kN).


Author(s):  
Mohammed Abdulhussein Al-Shuwaili ◽  
Alessandro Palmeri ◽  
Maria Teresa Lombardo

Push-out tests (POTs) have been widely exploited as an alternative to the more expensive full-scale bending tests to characterize the behaviour of shear connections in steel-concrete composite beams. In these tests, two concrete slabs are typically attached to a steel section with the connectors under investigation, which are then subjected to direct shear. The results allow quantifying the relationship between applied load and displacements at the steel-concrete interface. Since this relationship is highly influenced by the boundary conditions of POT samples, different experimental setups have been used, where the slabs are either restricted or free to slide horizontally, as researchers have tried to reduce any discrepancy between POT and full-scale composite beam testing. Based on a critical review of various POT configurations presented in the dedicated literature, this paper presents an efficient one-sided POT (OSPOT) method. While OSPOT and POT specimens are similar, in the proposed OPSPOT setup only one of the two slabs is directly loaded in each test, and the slab is free to move vertically. Thus, two results can be obtained from one specimen, i.e. one from each slab. A series of POTs and OSPOTs have been conducted to investigate the behaviour and the shear resistance of headed stud connectors through the two methods of testing. The results of this study than were compared with those of different POTs setups conducted by other researchers. The new OSPOT results show in general an excellent agreement with the analytical predictions offered by both British and European standards, as well as the estimated shear resistance proposed other researchers in the literature. These findings suggest that the proposed one-sided setup could be used as an efficient and economical option for conducting the POT, as it has the potential not only to double the number of results, but also to simplify the fabrication of the samples, which is important in any large experimental campaign, and to allow testing with limited capacity of the actuator. 


Sign in / Sign up

Export Citation Format

Share Document