scholarly journals Increased pulsatility index is associated with adverse outcomes in left ventricular assist device recipients

2021 ◽  
Author(s):  
Zuzana Tucanova ◽  
Peter Ivak ◽  
Peter Wohlfahrt ◽  
Marek Pol ◽  
Daniel Hlavacek ◽  
...  
2020 ◽  
Vol 43 (7) ◽  
pp. 452-460
Author(s):  
Jacob J Schaefer ◽  
Pavol Sajgalik ◽  
Sudhir S Kushwaha ◽  
Lyle J Olson ◽  
John M Stulak ◽  
...  

HeartMate II left ventricular assist device controllers provide data including pulsatility index, reflecting the relationship between pump function and hemodynamics. We propose that a higher pulsatility index at hospital discharge following implant may be associated with less vascular congestion and improved clinical outcomes. A retrospective analysis of 40 patients (age 59.2 ± 10.3 years) supported with the HeartMate II devices was conducted. Data revealed moderate Pearson correlations between pulsatility index at discharge and right atrial pressure, pulmonary artery systolic pressure, pulmonary artery diastolic pressure, mean pulmonary arterial pressure, and pulmonary capillary wedge pressure, respectively, post-surgery (median of 377 days), demonstrating a stronger relationship when analyzed for the EPC controller (n = 28) only (r = −.57, p < .01; r = −.38, p < .05; r = −.59, p < .01; r = −.47, p = .01 and r = −.53, p < .01, respectively). The pulsatility index derived from the EPC controller was associated with the significant risk of re-hospitalization within 1 and 2 years after the implantation of left ventricular assist device; hazard ratio = 0.557 with 95% confidence interval (0.315–0.983), p = .04 and hazard ratio = .579 (0.341–0.984), p = .04. A higher pulsatility index at discharge was associated with greater volume unloading, lower pulmonary pressures, and lower risk of all-cause re-hospitalizations within 1 and 2 years post-surgery. As such, pump-derived data may provide additional value in predicting left ventricular assist device hemodynamics.


PLoS ONE ◽  
2020 ◽  
Vol 15 (11) ◽  
pp. e0242931
Author(s):  
Tristan de Nattes ◽  
Pierre-Yves Litzler ◽  
Arnaud Gay ◽  
Catherine Nafeh-Bizet ◽  
Arnaud François ◽  
...  

Background Chronic subclinical hemolysis is frequent in patients implanted with Left Ventricular Assist Device (LVAD) and is associated with adverse outcomes. Consequences of LVADs-induced subclinical hemolysis on kidney structure and function is currently unknown. Methods Thirty-three patients implanted with a Heartmate II LVAD (Abbott, Inc, Chicago IL) were retrospectively studied. Hemolysis, Acute Kidney Injury (AKI) and the evolution of estimated Glomerular Filtration Rate were analyzed. Proximal Tubulopathy (PT) groups were defined according to proteinuria, normoglycemic glycosuria, and electrolytic disorders. The Receiver Operating Characteristic (ROC) curve was used to analyze threshold of LDH values associated with PT. Results Median LDH between PT groups were statistically different, 688 IU/L [642–703] and 356 IU/L [320–494] in the “PT” and “no PT” groups, respectively p = 0.006. To determine PT group, LDH threshold > 600 IU/L was associated with a sensitivity of 85.7% (95% CI, 42.1–99.6) and a specificity of 84.6% (95% CI, 65.1–95.6). The ROC's Area Under Curve was 0.83 (95% CI, 0.68–0.98). In the “PT” group, patients had 4.2 [2.5–5.0] AKI episodes per year of exposure, versus 1.6 [0.4–3.7] in the “no PT” group, p = 0.03. A higher occurrence of AKI was associated with subsequent development of Chronic Kidney Disease (CKD) (p = 0.02) and death (p = 0.05). Conclusions LVADs-induced subclinical hemolysis is associated with proximal tubular functional alterations, which in turn contribute to the occurrence of AKI and subsequent CKD. Owing to renal toxicity of hemolysis, measures to reduce subclinical hemolysis intensity as canula position or pump parameters should be systematically considered, as well as specific nephroprotective therapies.


Sign in / Sign up

Export Citation Format

Share Document