Health Literacy as a Predictor of Adverse Outcomes after Implantation of Left Ventricular Assist Device

2015 ◽  
Vol 21 (8) ◽  
pp. S98
Author(s):  
David Raymer ◽  
Justin Vader ◽  
Anne Platts ◽  
Michael Nassif ◽  
Scott Silvestry ◽  
...  
PLoS ONE ◽  
2020 ◽  
Vol 15 (11) ◽  
pp. e0242931
Author(s):  
Tristan de Nattes ◽  
Pierre-Yves Litzler ◽  
Arnaud Gay ◽  
Catherine Nafeh-Bizet ◽  
Arnaud François ◽  
...  

Background Chronic subclinical hemolysis is frequent in patients implanted with Left Ventricular Assist Device (LVAD) and is associated with adverse outcomes. Consequences of LVADs-induced subclinical hemolysis on kidney structure and function is currently unknown. Methods Thirty-three patients implanted with a Heartmate II LVAD (Abbott, Inc, Chicago IL) were retrospectively studied. Hemolysis, Acute Kidney Injury (AKI) and the evolution of estimated Glomerular Filtration Rate were analyzed. Proximal Tubulopathy (PT) groups were defined according to proteinuria, normoglycemic glycosuria, and electrolytic disorders. The Receiver Operating Characteristic (ROC) curve was used to analyze threshold of LDH values associated with PT. Results Median LDH between PT groups were statistically different, 688 IU/L [642–703] and 356 IU/L [320–494] in the “PT” and “no PT” groups, respectively p = 0.006. To determine PT group, LDH threshold > 600 IU/L was associated with a sensitivity of 85.7% (95% CI, 42.1–99.6) and a specificity of 84.6% (95% CI, 65.1–95.6). The ROC's Area Under Curve was 0.83 (95% CI, 0.68–0.98). In the “PT” group, patients had 4.2 [2.5–5.0] AKI episodes per year of exposure, versus 1.6 [0.4–3.7] in the “no PT” group, p = 0.03. A higher occurrence of AKI was associated with subsequent development of Chronic Kidney Disease (CKD) (p = 0.02) and death (p = 0.05). Conclusions LVADs-induced subclinical hemolysis is associated with proximal tubular functional alterations, which in turn contribute to the occurrence of AKI and subsequent CKD. Owing to renal toxicity of hemolysis, measures to reduce subclinical hemolysis intensity as canula position or pump parameters should be systematically considered, as well as specific nephroprotective therapies.


Author(s):  
J P Cassella ◽  
V Salih ◽  
T R Graham

Left ventricular assist systems are being developed for eventual long term or permanent implantation as an alternative to heart transplantation in patients unsuitable for or denied the transplant option. Evaluation of the effects of these devices upon normal physiology is required. A preliminary study was conducted to evaluate the morphology of aortic tissue from calves implanted with a pneumatic Left Ventricular Assist device-LVAD. Two 3 month old heifer calves (calf 1 and calf 2) were electively explanted after 128 days and 47 days respectively. Descending thoracic aortic tissue from both animals was removed immediately post mortem and placed into karnovsky’s fixative. The tissue was subsequently processed for transmission electron microscopy (TEM). Some aortic tissue was fixed in neutral buffered formalin and processed for routine light microscopy.


Sign in / Sign up

Export Citation Format

Share Document