Spectrophotometric Determination of Piroxicam via Chelation with Fe(III) in Commercial Dosage Forms

2009 ◽  
Vol 56 (6) ◽  
pp. 1083-1091 ◽  
Author(s):  
Syed Najmul Hejaz Azmi ◽  
Bashir Iqbal ◽  
Muna Ahmed Mohad Jaboob ◽  
Warda Ali Said Al Shahari ◽  
Nafisur Rahman
1976 ◽  
Vol 59 (4) ◽  
pp. 807-810
Author(s):  
Jeffrey C Hamm

Abstract The USP analysis for procainamide HCl is titrimetric and relatively nonspecific, capsule and tablet dyes may interfere, and the method is not applicable to coated tablets. In the spectrophotofluorometric method the sample deteriorates when exposed to a xenon source. In the ultraviolet spectrophotometric method reported here, the sample is dispersed in acid medium, possible interferences are extracted in chloroform, base is added, procainamide is extracted in chloroform, the residue is dissolved in sodium hydroxide, and the compound is measured by absorption at 272 nm and comparison with a standard. Recoveries of standards added to capsule, tablet, and injection composites ranged from 99.3 to 102%. Twelve collaborators reported duplicate assay results for all 3 dosage forms with per cent standard deviations for 5 samples ranging from 1.01 to 1.27%. The method has been adopted as official first action.


Author(s):  
Mohammed A.S. Abourehab ◽  
Mostafa H.K. Shahin ◽  
Ragaa El Sheikh ◽  
Abd Ellateif ◽  
Shymaa M. Fawzi ◽  
...  

1985 ◽  
Vol 68 (6) ◽  
pp. 1222-1225
Author(s):  
Mohamed E Mohamed ◽  
Hassan Y Aboul-Enein

Abstract Pirbuterol hydrochloride has been assayed in alkaline medium by using a fluorometric method to measure fluorescence intensity at 372 nm with excitation at 310 nm and by the ▵A method at 242 nm.The linearity ranges are 0.5-4 μg/mL and 10-50 μg/mL, respectively. An authentic pirbuterol HC1 sample was analyzed by nonaqueous potentiometric titration using 0.1N perchloric acid, and the results were compared with those for fluorometric and AA methods. The mean percent recoveries for the authentic sample were 98.72 ± 1.13 and 99.24 ± 0.85, respectively. When applied to commercial capsules containing 10 mg and 15 mg each, the fluorometric method gave mean percent recoveries of 101.11 ± 1.05 and 98.12 ± 0.93; the ▵A method gave mean percent recoveries of 100.57 ± 0.83 and 97.80 ± 0.75, respectively.


2000 ◽  
Vol 83 (6) ◽  
pp. 1440-1445 ◽  
Author(s):  
Hosakere D Revanasiddappa ◽  
Bochhe Gowda Manju

Abstract A simple, accurate, and rapid method for the quantitative determination of ritodrine hydrochloride (RTH) and isoxsuprine hydrochloride (ISH) in both pure and dosage forms, is described. The method is based on the development of pink colored product as a result of the condensation of 4-aminoantipyrine with phenols in the presence of an alkaline oxidizing agent. The resulting products are measured at 510 nm for both drugs, with molar absorptivities of 0.98 × 104 and 1.20 × 104 L/mol·cm for RTH and ISH, respectively. A study of the effect of commonly associated excipients revealed that they did not cause interference.


2010 ◽  
Vol 60 (2) ◽  
pp. 217-227 ◽  
Author(s):  
Padmarajaiah Nagaraja ◽  
Ashwinee Shrestha ◽  
Anantharaman Shivakumar ◽  
Avinash Gowda

Use ofN, N-diethyl-p-phenylenediamine sulphate for the spectrophotometric determination of some phenolic and amine drugsSpectrophotometric methods are proposed for the determination of drugs containing a phenol group [salbutamol sulphate (SLB), ritodrine hydrochloride (RTD), isoxsuprine hydrochloride (IXP)] and drugs containing an aromatic amine group [dapsone hydrochloride (DAP), sulfamethoxazole (SFM), and sulfadiazine (SFD)] in pharmaceutical dosage forms. The methods are based on coupling ofN, N-diethyl-p-phenylenediamine sulphate with the drugs in the presence of KIO4to give a green colored product (λmaxat 670 nm) and a red colored product (λmaxat 550 nm), respectively. Linear relationships with good correlation coefficients (0.9986-0.9996) were found between absorbance and the corresponding concentration of drugs in the range 1-7, 2-22, 1-17, 1.5-12, 2-25, and 2-21 μg mL-1for SLB, RTD, IXP, DAP, SFM and SFD, respectively. Variable parameters such as temperature, reaction time and concentration of the reactants have been analyzed and optimized. The RSD of intra-day and inter-day studies was in the range of 0.2-1.0 and 0.4-1.0%, respectively. No interference was observed from common pharmaceutical adjuvants. The reliability and performance of the proposed methods was validated statistically; the percentage recovery ranged from 99.5 ± 0.1 to 99.9 ± 0.3%. Limits of detection were 0.14, 0.21, 0.51, 0.44, 0.33 and 0.37 μg mL-1for SLB, RTD, IXP, DAP, SFM, and SFD, respectively.


Sign in / Sign up

Export Citation Format

Share Document