Difference spectrophotometric determination of telmisartan in tablet dosage forms

2006 ◽  
Vol 68 (5) ◽  
pp. 685 ◽  
Author(s):  
AR Bhat ◽  
MS Palled ◽  
M Chatter ◽  
PMN Rajesh
2006 ◽  
Vol 68 (3) ◽  
pp. 373 ◽  
Author(s):  
A Suganthi ◽  
HB Sivakumar ◽  
SC Vijayakumar ◽  
P Ravimathi ◽  
TK Ravi

2015 ◽  
Vol 6 (3s) ◽  
pp. 126-129
Author(s):  
Bharampuram Akhil ◽  
Routhu Krishna Chaitanya ◽  
Bukkapatnam Venkatesh ◽  
Mukthinuthalapati Mathrusri Annapurna

2010 ◽  
Vol 7 (s1) ◽  
pp. S314-S318 ◽  
Author(s):  
R. Vijayalakshmi ◽  
S. Bhargavi ◽  
M. D. Dhanaraju

Two accurate, precise, sensitve and economical procedures for simultaneous estimation of cetrizine and dextromethorphan in tablet dosage forms have been developed. First method employs formation and solving of simultaneous equations using 230 nm and 280 nm as two analytical wavelengths for both drugs in methanol. The second method isQ-analysis based on measurement of absorptivity at 224 nm (as isobestic point) and 280 nm (λmaxof CTZ). Cetrizine and dextromethorphan at their respective λmax280 nm and 230 nm and at 224 nm (isobestic point) shows linearity in a concentration range of 10-30 mcg/mL for both the drugs. The recovery studies confirmed accuracy of the proposed methods and low values of standard deviation confirmed precision of the methods. The methods were validated as per ICH guidelines.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
J. Saroja ◽  
Anantha Lakshmi P.V. ◽  
Y. Rammohan ◽  
D. Divya Reddy

Abstract Background We describe a “stability-indicating liquid chromatography” technique for the estimation of dimethicone (DEC) and dicyclomine hydrochloride (DEH) in the established tablet formulations. Individual quantification of DEH and DEC was reported. But simultaneous quantification of DEH and DEC was lacking. DEH and DEC were analysed on an “XTerra C18 column (250 mm × 4.6 mm, 5 μm)” with the mobile phase solvent run isocratically with 0.1M K2HPO4-acetonitrile (55:45, v/v) on a flow speed of 1.0 mL/min. Results The chromatographic run period for the DEC and DEH assay was 6.0 min with retention times of 2.134 and 2.865 min, respectively. The method was validated for accuracy (99.453 to 100.417% and 99.703 to 100.303% recovery values for DEH and DEC, respectively), precision (RSV value 0.135% for DEC and 0.171% for DEH), linearity (5–15 μg/mL for DEH and 20–60 μg/mL for DEC), selectivity (no hinderance from excipients) and specificity (no hinderance from degradants) recovery. Conclusion The developed stability-indicating liquid chromatography process was well applied to established tablet formulations.


1976 ◽  
Vol 59 (4) ◽  
pp. 807-810
Author(s):  
Jeffrey C Hamm

Abstract The USP analysis for procainamide HCl is titrimetric and relatively nonspecific, capsule and tablet dyes may interfere, and the method is not applicable to coated tablets. In the spectrophotofluorometric method the sample deteriorates when exposed to a xenon source. In the ultraviolet spectrophotometric method reported here, the sample is dispersed in acid medium, possible interferences are extracted in chloroform, base is added, procainamide is extracted in chloroform, the residue is dissolved in sodium hydroxide, and the compound is measured by absorption at 272 nm and comparison with a standard. Recoveries of standards added to capsule, tablet, and injection composites ranged from 99.3 to 102%. Twelve collaborators reported duplicate assay results for all 3 dosage forms with per cent standard deviations for 5 samples ranging from 1.01 to 1.27%. The method has been adopted as official first action.