scholarly journals Crown Ethers Bearing 18C6 Unit; Sensory Molecules for Fabricating PVC Membrane Lead Ion-selective Electrodes

2011 ◽  
Vol 58 (5) ◽  
pp. 673-680 ◽  
Author(s):  
A. A. Zamani ◽  
N. Khorsihdi ◽  
Z. Mofidi ◽  
M. R. Yaftian
2009 ◽  
Vol 2009 ◽  
pp. 1-7 ◽  
Author(s):  
Hassan Arida ◽  
Mona Ahmed ◽  
Abdallah Ali

The fabrication and electrochemical evaluation of two PVC membrane-based Ion-Selective electrodes responsive for ramipril drug have been proposed. The sensitive membranes were prepared using ramipril-phosphomolibdate and ramipril-tetraphenylborate ion-pair complexes as electroactive sensing materials in plasticized PVC support. The electrodes based on these materials provide near-Nernestian response (sensitivity of53±0.5–54±0.5 mV/concentration decade) covering the concentration range of1.0×10-2–1.0×10-5 molL−1with a detection limit of3.0×10-6–4.0×10-6 molL−1. The suggested electrodes have been successfully used in the determination of ramipril drug in some pharmaceutical formulations using direct potentiometry with average recovery of >96% and mean standard deviation of <3% (n=5).


Polymers ◽  
2020 ◽  
Vol 12 (6) ◽  
pp. 1343 ◽  
Author(s):  
Ayman H. Kamel ◽  
Abd El-Galil E. Amr ◽  
Nashwa H. Ashmawy ◽  
Hoda R. Galal ◽  
Abdulrahman A. Almehizia ◽  
...  

A simple, rapid and easy method is proposed for the detection of a cytostatic therapeutic drug, cytarabine, in real samples. The method is based on potentiometric transduction using prepared and characterized new ion-selective electrodes for cytarabine. The electrodes were integrated with novel man-tailored imprinted polymers and used as a sensory element for recognition. The electrodes revealed a remarkable potentiometric response for cytarabine over the linearity range 1.0 × 10−6–1.0 × 10−3 M at pH 2.8–4 with a detection limit of 5.5 × 10−7 M. The potentiometric response was near-Nernstian, with average slopes of 52.3 ± 1.2 mV/decade. The effect of lipophilic salts and plasticizer types on the potentiometric response was also examined. The electrodes exhibited an enhanced selectivity towards cytarabine over various foreign common ions. Validation and verification of the presented assay method are demonstrated by evaluating the method ruggedness and calculating the detection limit, range of linearity, accuracy (trueness), precision, repeatability (within-day) and reproducibility (between-days). The proposed ion-selective electrodes revealed good performance characteristics and possible application of these electrodes for cytarabine monitoring in different matrices. The electrodes are successfully applied to cytarabine determination in spiked biological fluid samples and in pharmaceutical formulations.


2021 ◽  
Vol 1227 ◽  
pp. 129575
Author(s):  
Deneikah T. Jackson ◽  
Peter N. Nelson ◽  
Irvin N. Booysen

1991 ◽  
Vol 63 (20) ◽  
pp. 2282-2285 ◽  
Author(s):  
Sudersan M. Tuladhar ◽  
Gwyn. Williams ◽  
Claudius. D'Silva

Talanta ◽  
1998 ◽  
Vol 46 (6) ◽  
pp. 1341-1346 ◽  
Author(s):  
Ahmad Rouhollahi ◽  
Mohammad Reza Ganjali ◽  
Mojtaba Shamsipur

2005 ◽  
Vol 107 (1) ◽  
pp. 438-445 ◽  
Author(s):  
M. Mazloum Ardakani ◽  
M. Khayat Kashani ◽  
M. Salavati-Niasari ◽  
A.A. Ensafi

Sign in / Sign up

Export Citation Format

Share Document