Physiological and kinetic evaluation of ampicillin oxidation as unique electron source by a denitrifying sludge

Author(s):  
Banda Yeny ◽  
Texier Anne‐Claire ◽  
Cuervo‐López Flor
Author(s):  
P.H. McLaughlin

A shelved structure for the support of an electron optical column affords advantages both to the designer and the user. A lens may be removed for cleaning for example, without demounting the remaining lenses. A custom device for another example, may be placed on a shelf, substituting for the standard lens perhaps so that some specialized research may be undertaken. Especially advantageous is a shelved arrangement if the column assembly is designed to hang from a supporting structure such as a gas borne floating platform, as is the case with the system described below.As shown on the schematic, a floating platform (I) supports the electron source apparatus (2) and a U-shaped column support shelf (3). The column support shelf acts as a key for locating and supporting three struts (4) which with nuts (5) support the condenser shelf (6), the objective shelf (7), the upper projector shelf (8), and the lower projector shelf (9).


Author(s):  
A. Strojnik ◽  
J.W. Scholl ◽  
V. Bevc

The electron accelerator, as inserted between the electron source (injector) and the imaging column of the HVEM, is usually a strong lens and should be optimized in order to ensure high brightness over a wide range of accelerating voltages and illuminating conditions. This is especially true in the case of the STEM where the brightness directly determines the highest resolution attainable. In the past, the optical behavior of accelerators was usually determined for a particular configuration. During the development of the accelerator for the Arizona 1 MEV STEM, systematic investigation was made of the major optical properties for a variety of electrode configurations, number of stages N, accelerating voltages, 1 and 10 MEV, and a range of injection voltages ϕ0 = 1, 3, 10, 30, 100, 300 kV).


Author(s):  
M. Iwatsuki ◽  
Y. Kokubo ◽  
Y. Harada

On accout of its high brightness, small optical source size, and minimal energy spread, the field emission gun (FEG) has the advantage that it provides the conventional transmission electron microscope (TEM) with a highly coherent illumination system and directly improves the resolving power and signal-to-noise ratio of the scanning electron microscope (SEM). The FEG is generally classified into two types; the cold field emission (C-FEG) and thermal field emission gun (T-FEG). The former, in which a field emitter is used at the room temperature, was successfully developed as an electron source for the SEM. The latter, in which the emitter is heated to the temperature range of 1000-1800°K, was also proved to be very suited as an electron source for the TEM, as well as for the SEM. Some characteristics of the two types of the FEG have been studied and reported by many authors. However, the results of the respective types have been obtained separately under different experimental conditions.


2012 ◽  
Vol 11 (4) ◽  
pp. 829-839 ◽  
Author(s):  
Siti Rozaimah Sheikh Abdullah ◽  
Mohd Hafizuddin Muhamad ◽  
Abu Bakar Mohamad ◽  
Rakmi Abdul Rahman ◽  
Abdul Amir Hasan Kadhum

1988 ◽  
Vol 20 (11-12) ◽  
pp. 131-136 ◽  
Author(s):  
A. D. Wong ◽  
C. D. Goldsmith

The effect of discharging specific oil degrading bacteria from a chemostat to a refinery activated sludge process was determined biokinetically. Plant data for the kinetic evaluation of the waste treatment plant was collected before and during treatment. During treatment, the 500 gallon chemostatic growth chamber was operated on an eight hour hydraulic retention time, at a neutral pH, and was fed a mixture of refinery wastewater and simple sugars. The biokinetic constants k (days−1), Ks (mg/L), and K (L/mg-day) were determined before and after treatment by Monod and Lineweaver-Burk plots. Solids discharged and effluent organic concentrations were also evaluated against the mean cell retention time (MCRT). The maximum utilization rate, k, was found to increase from 0.47 to 0.95 days−1 during the operation of the chemostat. Subsequently, Ks increased from 141 to 556 mg/L. Effluent solids were shown to increase slightly with treatment. However, this was acceptable due to the polishing pond and the benefit of increased ability to accept shock loads of oily wastewater. The reason for the increased suspended solids in the effluent was most likely due to the continual addition of bacteria in exponential growth that were capable of responding to excess substrate. The effect of the chemostatic addition of specific microbial inocula to the refinery waste treatment plant has been to improve the overall organic removal capacity along with subsequent gains in plant stability.


1999 ◽  
Vol 70 (10) ◽  
pp. 3886-3888 ◽  
Author(s):  
M. Adelt ◽  
R. Körber ◽  
W. Drachsel ◽  
H.-J. Freund

Author(s):  
J. G. H. Franssen ◽  
T. C. H. de Raadt ◽  
M. A. W. van Ninhuijs ◽  
O. J. Luiten

Sign in / Sign up

Export Citation Format

Share Document