scholarly journals Editorial to implantable cardioverter defibrillator and cardiac resynchronization therapy use in New Zealand (ANZACS‐QI 33)

2019 ◽  
Vol 36 (1) ◽  
pp. 164-165
Author(s):  
Hitoshi Minamiguchi
2020 ◽  
Author(s):  
MEI YANG ◽  
Xuping Li ◽  
John C. Morris III ◽  
Jinjun Liang ◽  
Abhishek J. Deshmukh ◽  
...  

Abstract Background Hypothyroidism is known to be associated with adverse clinical outcomes in heart failure. The association between hypothyroidism and cardiac resynchronization therapy outcomes in patients with severe heart failure is not clear. Methods The study included 1,316 patients who received cardiac resynchronization therapy between 2002 and 2015. Baseline demographics and cardiac resynchronization therapy outcomes, including left ventricular ejection fraction, New York Heart Association class, appropriate implantable cardioverter-defibrillator therapy, and all-cause mortality, were collected from the electronic health record. Results Of the study cohort, 350 patients (26.6%) were classified as the hypothyroidism group. The median duration of follow-up was 3.6 years (interquartile range, 1.7-6.2). Hypothyroidism was not associated with a higher risk of all-cause mortality in patients receiving CRT for heart failure. The risk of appropriate implantable cardioverter-defibrillator therapy significantly increased in association with increased baseline thyroid -stimulating hormone level in the entire cohort (hazard ratio, 1.23 per 5mIU/L increase; 95% CI, 1.01-1.5; P=0.04) as well as in the hypothyroid group (hazard ratio, 1.44 per 5mIU/L increase; 95% CI, 1.13-1.84; P=0.004). Conclusions CRT improves cardiac function in hypothyroid patients. The ventricular arrhythmic events requiring ICD therapies are associated with baseline TSH level, which might be considered as an important biomarker to stratify the risk of sudden death for patients with heart failure and hypothyroidism.


Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Qi Zheng ◽  
Sarah Goodlin

Background: Implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT-D) reduce mortality and improve functional status in selected patients with heart failure (HF). However, there are potential procedural risks and psychosocial concerns associated with device implant. This qualitative study aims to explore patients’ and families’ understanding of ICD/CRT-D, heart failure and arrhythmia in the process of decision making regarding device implant. Methods: We conducted 14 focus groups or interviews in Salt Lake City UT and Silver Spring MD. This study included 23 patients, who had either an ICD or CRT-D implant for primary prevention, and 14 family members. Grounded theory analysis was performed to reach a conceptual understanding of patients’ and families’ perceptions and needs. Results: Patients and families largely made decision of ICD/CRT implant based on physicians’ recommendations, e.g. “I really try to do what they tell me to do” (icdpt 1). Patients perceived ICD as lifesaving and CRT being helpful to improve functional status. Many patients described ICD as lifesaving by “restarting a heart if it stops”, while did not understand HF or ventricular arrhythmia. Patients perceived an urgency to consider ICD implant from their physicians, but no such urgency was perceived when they discussed about CRT-D implant. Few participants were concerned with costs, or had knowledge of potential lead malfunction, device removal and associated risks. Many emphasized the importance of information about life expectancies, what HF is, options of different devices, complications and precautions, and what to expect regarding lifestyle changes. Conclusion: Patients and families largely relied on the information provided by physicians and followed physicians’ guidance. They had limited understanding of their prognosis, HF and arrhythmia, and they were motivated to learn. Discussion about devices should include prognosis and healthy life style changes.


Author(s):  
Nicola Meldrum ◽  
Andrew Mitchell

This chapter describes the device clinic. Requirements for a suitable facility, including maintaining patient dignity, are covered, and the development of remote follow-up is defined, including advantages and disadvantages. The follow-up schedule is covered, and history taking and examination are covered. Pacemaker testing and interrogation are shown, to aid the physician in management, diagnosis, and optimization of programming. Implantable cardioverter defibrillator (ICD) follow-up is also described, with all additional information required for follow-up described. Finally, cardiac resynchronization therapy (CRT) follow-up differences from standard pacemaker checks are covered.


Sign in / Sign up

Export Citation Format

Share Document