A Decentralized Multichannel Length Transformation Algorithm and Its Parallel Implementation for Real-Time ECG Monitoring

2000 ◽  
Vol 33 (4) ◽  
pp. 227-244 ◽  
Author(s):  
A. Koulouris ◽  
G. Papakonstantinou ◽  
P. Tsanakas
Author(s):  
Jia Hua-Ping ◽  
Zhao Jun-Long ◽  
Liu Jun

Cardiovascular disease is one of the major diseases that threaten the human health. But the existing electrocardiograph (ECG) monitoring system has many limitations in practical application. In order to monitor ECG in real time, a portable ECG monitoring system based on the Android platform is developed to meet the needs of the public. The system uses BMD101 ECG chip to collect and process ECG signals in the Android system, where data storage and waveform display of ECG data can be realized. The Bluetooth HC-07 module is used for ECG data transmission. The abnormal ECG can be judged by P wave, QRS bandwidth, and RR interval. If abnormal ECG is found, an early warning mechanism will be activated to locate the user’s location in real time and send preset short messages, so that the user can get timely treatment, avoiding dangerous occurrence. The monitoring system is convenient and portable, which brings great convenie to the life of ordinary cardiovascular users.


Electronics ◽  
2021 ◽  
Vol 10 (5) ◽  
pp. 627
Author(s):  
David Marquez-Viloria ◽  
Luis Castano-Londono ◽  
Neil Guerrero-Gonzalez

A methodology for scalable and concurrent real-time implementation of highly recurrent algorithms is presented and experimentally validated using the AWS-FPGA. This paper presents a parallel implementation of a KNN algorithm focused on the m-QAM demodulators using high-level synthesis for fast prototyping, parameterization, and scalability of the design. The proposed design shows the successful implementation of the KNN algorithm for interchannel interference mitigation in a 3 × 16 Gbaud 16-QAM Nyquist WDM system. Additionally, we present a modified version of the KNN algorithm in which comparisons among data symbols are reduced by identifying the closest neighbor using the rule of the 8-connected clusters used for image processing. Real-time implementation of the modified KNN on a Xilinx Virtex UltraScale+ VU9P AWS-FPGA board was compared with the results obtained in previous work using the same data from the same experimental setup but offline DSP using Matlab. The results show that the difference is negligible below FEC limit. Additionally, the modified KNN shows a reduction of operations from 43 percent to 75 percent, depending on the symbol’s position in the constellation, achieving a reduction 47.25% reduction in total computational time for 100 K input symbols processed on 20 parallel cores compared to the KNN algorithm.


Author(s):  
Nesrine Abid ◽  
Tarek Ouni ◽  
Kais Loukil ◽  
Mohamed Abid ◽  
Ahmed Chiheb Ammeri

Author(s):  
Hassan Ali ◽  
Ben Ernest Villaneouva ◽  
Raziq Yaqub

Due to the rising number of heart patients and the apparent need for more robust electrocardiogram (ECG) monitoring of these patients, hospitals are increasingly investing in typical cloud technology or centralized hospital server based remote ECG monitoring systems. However, the deployment these systems in rural communities is limited due to the high cost factor. To counter this challenge, in this paper, we focus on the design and implementation of a low cost real time wireless ambulatory ECG monitoring system. The detected ECG signals are first filtered and amplified and then digitally converted by a microcontroller. The digitized ECG signals are then sent over a ZigBee wireless link to a gateway personal computer (PC) at patient’s premises. The received ECG data from the ZigBee connection is displayed in real time via the National Instruments (NI) Laboratory Virtual Instrument Engineering Workbench (LabVIEW) user interface on the PC for instant personalized evaluation of the ECG data. The ECG data can be saved on the PC and sent via email to a remote cardiologist or a clinician. Additionally, the gateway PC at patient’s end acts as web server for sharing patient’s data over the Internet.  The remote off-site physician (medical staff in a hospital) can use a web browser on a PC, laptop or a mobile phone with Internet connection to access patient’s real time ECG trace for monitoring, expert review and diagnosis. It is shown that the system prototype allows users to acquire reliable ECG signals effectively and simply. The proposed ambulatory ECG system offers an alternative low cost deployment strategy and is especially suited for remote cardiac monitoring of patients in rural communities.


Sign in / Sign up

Export Citation Format

Share Document