scholarly journals Robotic Needle Steering: Design, Modeling, Planning, and Image Guidance

2010 ◽  
pp. 557-582 ◽  
Author(s):  
Noah J. Cowan ◽  
Ken Goldberg ◽  
Gregory S. Chirikjian ◽  
Gabor Fichtinger ◽  
Ron Alterovitz ◽  
...  
Neurosurgery ◽  
2010 ◽  
Vol 67 (4) ◽  
pp. 1117-1123 ◽  
Author(s):  
Johnathan A Engh ◽  
Davneet S Minhas ◽  
Douglas Kondziolka ◽  
Cameron N Riviere

Abstract BACKGROUND: Intracerebral drug delivery using surgically placed microcatheters is a growing area of interest for potential treatment of a wide variety of neurological diseases, including tumors, neurodegenerative disorders, trauma, epilepsy, and stroke. Current catheter placement techniques are limited to straight trajectories. The development of an inexpensive system for flexible percutaneous intracranial navigation may be of significant clinical benefit. OBJECTIVE: Utilizing duty-cycled spinning of a flexible bevel-tipped needle, the authors devised and tested a means of achieving nonlinear trajectories for the navigation of catheters in the brain, which may be applicable to a wide variety of neurological diseases. METHODS: Exploiting the bending tendency of bevel-tipped needles due to their asymmetry, the authors devised and tested a means of generating curvilinear trajectories by spinning a needle with a variable duty cycle (ie, in on-off fashion). The technique can be performed using image guidance, and trajectories can be adjusted intraoperatively via joystick. Fifty-eight navigation trials were performed during cadaver testing to demonstrate the efficacy of the needle-steering system and to test its precision. RESULTS: The needle-steering system achieved a target acquisition error of 2 ± 1 mm, while demonstrating the ability to reach multiple targets from one burr hole using trajectories of varying curvature. CONCLUSION: The accuracy of the needle-steering system was demonstrated in a cadaveric model. Future studies will determine the safety of the device in vivo.


Skull Base ◽  
2005 ◽  
Vol 15 (S 2) ◽  
Author(s):  
Michael Mokry ◽  
H. Stammberger ◽  
W. Köle ◽  
P. Reittner

2020 ◽  
Vol 8 (Suppl 3) ◽  
pp. A422-A422
Author(s):  
Ravi Murthy ◽  
Rahul Sheth ◽  
Alda Tam ◽  
Sanjay Gupta ◽  
Vivek Subbiah ◽  
...  

BackgroundImage guided intra-tumor administration of investigational immunotherapeutic agents represents an expanding field of interest. We present a retrospective review of the safety, feasibility & technical nuances of real-time image guidance for injection & biopsy across a spectrum of extracranial solid malignancies utilizing the discipline of Interventional Radiology.MethodsPatients who were enrolled in image guided intratumoral immunotherapy injection (ITITI) clinical trials over a 6 year period (2013–19) at a single tertiary care cancer center were included in this analysis. Malignancy, location, imaging guidance utilized for ITITI & biopsy for injected (adscopal) & non-injected (abscopal) lesions were determined and categorized. Peri-procedural adverse events were noted.Results262 pts (146 female, 61 yrs median) participating in 29 immunotherapeutic clinical trials (TLR & STING agonists, gene therapy, anti CD-40, viral/bacterial/metabolic oncolytics) met study criteria. Malignancies included melanoma 88, sarcoma 32, colorectal 29, breast 23, lung 17, head & neck 15, ovarian 8, neuroendocrine 7, pancreatic adenocarcinoma 6, 3 each (cholangioCA, endometrial, bladder, GI tract), 2 each (RCC, thymicCA, lymphoma, merkel cell, prostate) & others 1 each (CUP, GIST, dermatofibrosarcoma, DSRT, neuroblastoma, thyroid). All 169 & 93 patients received the intended 1371 ITITI in parietal (abdominal/chest wall, extremity, neck, pelvis) or visceral (liver, lung, peritoneum, adrenal) locations respectively; 83 patients received lymph node injections within either location. Imaging guidance was US in 68% of the cohort (US 161, CT+US 19); CT was used in 30% (81) & MRI in 1 patient. Median diameter of the ITITI lesion was 32 mm (8–230 mm). Median volume of the ITITI therapeutic material/session was 2 ml (1–6.9 ml). Lesions were accessed using a coaxial technique. ITITI delivery needles used at operator preference & tailored to lesion characteristics were either a 21G/22G Chiba, 21G Profusion (Cook Medical), 22G Morrison (AprioMed), 25G hypodermic (BD) & 18G Quadrafuse (Rex Medical). 2840 core biopsies (>18G Tru-cut core, Mission, Bard Medical) were performed in 237 patients during 690 procedures; biopsy sessions were often concurrent & of the ITITI site. 137 patients also underwent biopsy of a non-ITITI site (89 parietal location). Dimensions of the non-ITITI lesion were median 10 mm (7–113 mm); US image guidance was used in 97 patients (72%) to obtain a total of 1257, >18G Tru-core samples. 1.3% of injections resulted in SAE (NCI CTC AE >3) and 0.5% of 4097 biopsies developed major complications (SIR Criteria); both categories were manageable.ConclusionsUtilizing real time image guidance, ITITI to the administration of a myriad of investigational immunotherapeutic agents with concomitant biopsy procedures to date are associated with a high technical success rate & favorable safety profile.AcknowledgementsJoshua Hein, Mara Castaneda, Jyotsna Pera, Yunfang Jiang,Shuang Liu, Holly Liu and Anna LuiTrial RegistrationN/AEthics ApprovalThe study was approved by Institution’s Ethics Board, approval number 2020-0536: A retrospective study to determine the safety, feasibility and technical challenges of real-time image guidance for intra-tumor injection and biopsy across multiple solid tumors.Consent2020-0536 Waiver of Informed ConsentReferenceSheth RA, Murthy R, Hong DS, et al. Assessment of image-guided intratumoral delivery of immunotherapeutics in patients with cancer. JAMA Netw Open 2020;3(7):e207911. doi:10.1001/jamanetworkopen.2020.7911


Sign in / Sign up

Export Citation Format

Share Document