Breast and Tumor Bed

Author(s):  
Aylin Fidan Korcum ◽  
Melek Nur Yavuz
Keyword(s):  
2017 ◽  
Vol 13 (1) ◽  
pp. 4605-4617
Author(s):  
Aly Mahmoud El-Hdidy

Comparisons between three different techniques by which the boost dose was delivered to the tumor bed were carried out , aiming to present the best technique of treatment for right breast cancer patients.In this study, ten right sided breast cancer computed tomography (CT) scans were selected for ten early right breast cancer patients. We made three different treatment plans for each patient CT using three different irradiation techniques to deliver a prescribed boost dose of 10 Gy in 5 fractions to the boost PTV. In the first technique, two tangential photon beams were used, in the second technique we, two oblique photon beams were used and in the third technique, a single electron beam was used. The comparative analyses between the three techniques were performed by comparing the boost PTV- dose volume histograms (DVHs), the ipsilateral breast (right breast) DVHs, the ipsilateral lung (right lung) DVHs and the heart DVHs of the three techniques for each patient. Furthermore the dose that covering 100% , 95% of the volume (D100% , D95%) and the volume covered by 95% of the dose (V95%)of  the boost PTV of all techniques, were calculated for each patient to investigate the dose coverage of the target.Results showed that there were variations of the dose received by tumor bed, right breast and OARs depending on the technique used and the target location and size. A decrease of D100% than 90% of the prescribed dose was observed with the 3rd technique for patients 8, 9 and 10, and was observed with the 2nd technique for patient 5. A reduction of right breast dose was observed when the 3rd technique was use in comparison with the 1st and the 2nd techniques for patients 1, 2, 3, 4, 6 and 8.  Also reduction of right breast was observed when the 2nd technique used in comparison with 1st technique. An increase of lung dose was observed with the 3rd technique for patients 1, 2, 5 and 6, also was observed with 2nd technique in patient 3, 5 and 7. A decrease of lung dose was observed with the 1st technique for patients 2, 4, 5, 6, 7, 8 and 9An individualized treatment, several plans using different irradiation techniques should be developed for each patient individually to reach the best boost PTV dose coverage with minimal OARs’ dose. 


2015 ◽  
Vol 55 (4) ◽  
pp. 526-529
Author(s):  
Hsiang-Chi Kuo ◽  
Keyur J. Mehta ◽  
Leslie Montgomery ◽  
Viswanathan Shankar ◽  
Ravindra Yaparpalvi ◽  
...  

Diagnostics ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 516
Author(s):  
Daan Linders ◽  
Marion Deken ◽  
Maxime van der Valk ◽  
Willemieke Tummers ◽  
Shadhvi Bhairosingh ◽  
...  

Rectal cancer patients with a complete response after neoadjuvant therapy can be monitored with a watch-and-wait strategy. However, regrowth rates indicate that identification of patients with a pathological complete response (pCR) remains challenging. Targeted near-infrared fluorescence endoscopy is a potential tool to improve response evaluation. Promising tumor targets include carcinoembryonic antigen (CEA), epithelial cell adhesion molecule (EpCAM), integrin αvβ6, and urokinase-type plasminogen activator receptor (uPAR). To investigate the applicability of these targets, we analyzed protein expression by immunohistochemistry and quantified these by a total immunostaining score (TIS) in tissue of rectal cancer patients with a pCR. CEA, EpCAM, αvβ6, and uPAR expression in the diagnostic biopsy was high (TIS > 6) in, respectively, 100%, 100%, 33%, and 46% of cases. CEA and EpCAM expressions were significantly higher in the diagnostic biopsy compared with the corresponding tumor bed (p < 0.01). CEA, EpCAM, αvβ6, and uPAR expressions were low (TIS < 6) in the tumor bed in, respectively, 93%, 95%, 85%, and 62.5% of cases. Immunohistochemical evaluation shows that CEA and EpCAM could be suitable targets for response evaluation after neoadjuvant treatment, since expression of these targets in the primary tumor bed is low compared with the diagnostic biopsy and adjacent pre-existent rectal mucosa in more than 90% of patients with a pCR.


2013 ◽  
Vol 31 (36) ◽  
pp. 4488-4495 ◽  
Author(s):  
Mukesh B. Mukesh ◽  
Gillian C. Barnett ◽  
Jennifer S. Wilkinson ◽  
Anne M. Moody ◽  
Charles Wilson ◽  
...  

Purpose There are few randomized controlled trial data to confirm that improved homogeneity with simple intensity-modulated radiotherapy (IMRT) decreases late breast tissue toxicity. The Cambridge Breast IMRT trial investigated this hypothesis, and the 5-year results are reported. Patients and Methods Standard tangential plans of 1,145 trial patients were analyzed; 815 patients had inhomogeneous plans (≥ 2 cm3 receiving 107% of prescribed dose: 40 Gy in 15 fractions over 3 weeks) and were randomly assigned to standard radiotherapy (RT) or replanned with simple IMRT; 330 patients with satisfactory dose homogeneity were treated with standard RT and underwent the same follow-up as the randomly assigned patients. Breast tissue toxicities were assessed at 5 years using validated methods: photographic assessment (overall cosmesis and breast shrinkage compared with baseline pre-RT photographs) and clinical assessment (telangiectasia, induration, edema, and pigmentation). Comparisons between different groups were analyzed using polychotomous logistic regression. Results On univariate analysis, compared with standard RT, fewer patients in the simple IMRT group developed suboptimal overall cosmesis (odds ratio [OR], 0.68; 95% CI, 0.48 to 0.96; P = .027) and skin telangiectasia (OR, 0.58; 95% CI, 0.36 to 0.92; P = .021). No evidence of difference was seen for breast shrinkage, breast edema, tumor bed induration, or pigmentation. The benefit of IMRT was maintained on multivariate analysis for both overall cosmesis (P = .038) and skin telangiectasia (P = .031). Conclusion Improved dose homogeneity with simple IMRT translates into superior overall cosmesis and reduces the risk of skin telangiectasia. These results are practice changing and should encourage centers still using two-dimensional RT to implement simple breast IMRT.


Author(s):  
Philip Wong ◽  
Thierry Muanza ◽  
Eric Reynard ◽  
Karine Robert ◽  
Jennifer Barker ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document