Performance of SF6 Gas Mixtures in High-Voltage Circuit Breakers

2001 ◽  
pp. 455-460
Author(s):  
Hartmut Knobloch ◽  
Bernd-Ulrich Habedank
Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 5051
Author(s):  
John Owens ◽  
Ang Xiao ◽  
Jason Bonk ◽  
Michael DeLorme ◽  
Agnes Zhang

For many years, SF6 has been the preferred dielectric medium in electrical power applications, particularly in high voltage gas-insulated equipment. However, with the recognition that SF6 has an extremely long atmospheric lifetime and very high global warming potential, governments have pursued emission reductions from gas-filled equipment. The electrical power industry has responded to this environmental challenge applying SF6-free technologies to an expanding range of applications which have traditionally used SF6, including gas-insulated switchgear, gas-insulated circuit breakers and gas-insulated lines or bus bars. Some of these SF6-free solutions include gas mixtures containing fluorinated compounds that have low climate impact, among them, a fluoronitrile and a fluoroketone developed as 3M™ Novec™ 4710 Insulating Gas and 3M™ Novec™ 5110 Insulating Gas, respectively. Both fluoronitrile and fluoroketone mixtures are successfully used in gas-insulated equipment currently operating on the grid where they reduce greenhouse gas emissions by more than 99% versus SF6. This paper reviews these leading components of alternative-gas mixtures with updates on the performance, safety and environmental profiles in electrical power applications.


Author(s):  
Xin Lin ◽  
Jia Zhang ◽  
Jianyuan Xu ◽  
Jianying Zhong ◽  
Yu Song ◽  
...  

Electronics ◽  
2021 ◽  
Vol 10 (10) ◽  
pp. 1204
Author(s):  
Gul Ahmad Ludin ◽  
Mohammad Amin Amin ◽  
Hidehito Matayoshi ◽  
Shriram S. Rangarajan ◽  
Ashraf M. Hemeida ◽  
...  

This paper proposes a new and surge-less solid-state direct current (DC) circuit breaker in a high-voltage direct current (HVDC) transmission system to clear the short-circuit fault. The main purpose is the fast interruption and surge-voltage and over-current suppression capability analysis of the breaker during the fault. The breaker is equipped with series insulated-gate bipolar transistor (IGBT) switches to mitigate the stress of high voltage on the switches. Instead of conventional metal oxide varistor (MOV), the resistance–capacitance freewheeling diodes branch is used to bypass the high fault current and repress the over-voltage across the circuit breaker. The topology and different operation modes of the proposed breaker are discussed. In addition, to verify the effectiveness of the proposed circuit breaker, it is compared with two other types of surge-less solid-state DC circuit breakers in terms of surge-voltage and over-current suppression. For this purpose, MATLAB Simulink simulation software is used. The system is designed for the transmission of 20 MW power over a 120 km distance where the voltage of the transmission line is 220 kV. The results show that the fault current is interrupted in a very short time and the surge-voltage and over-current across the proposed breaker are considerably reduced compared to other topologies.


Entropy ◽  
2015 ◽  
Vol 18 (1) ◽  
pp. 7 ◽  
Author(s):  
Nantian Huang ◽  
Huaijin Chen ◽  
Shuxin Zhang ◽  
Guowei Cai ◽  
Weiguo Li ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document