Research on Contact Pressure of Friction Pair Based on Finite Element Method

Author(s):  
Changlu Wang ◽  
Long Wu ◽  
Zichun Xu ◽  
Yaping Zhang ◽  
Hao Gao ◽  
...  
2014 ◽  
Vol 672-674 ◽  
pp. 902-905 ◽  
Author(s):  
Chun Hua Sun ◽  
Guang Qing Shang

To protect dwindling coal and oil resources and open up a new way of renewable green energy, the technology of piezoelectric harvesting from pavement is proposed. Effect of traffic flow, including contact pressure and speed of a vehicle, on characteristics of a piezoelectric harvesting unit is discussed with the finite element method. Results show that the harvested electric power is approximately linear with the contact pressure and a vehicle’s speed. The contact pressure takes more effect on the harvested electric power and stress on pavement than the vehicle’s speed. A PHU of 280*280*20mm can harvest about 10mJ electric power when the contact pressure is 0.85MPa. That shows that application of the piezoelectric harvesting unit has very nice optimistic prospects.


2014 ◽  
Vol 601 ◽  
pp. 159-162
Author(s):  
Mircea Krepelka ◽  
Mirela Toth-Taşcău

In this study, periacetabular pressures produced by different acetabular liner geometries were analyzed using Finite Element Method. The cup models consist of hemispherical metal shells fitted with normal and different chamfered polyethylene liner geometries, with the same degree of femoral head coverage. The aim of this study was to understand the influence of the design parameters of the chamfered liners, which are primarily designed to increase the range of motion (ROM) of the hip joint and reduce the risk of impingement, on the acetabular contact pressures. The cup models were loaded to simulate periacetabular pressures during routine activities. The proposed models have been analyzed considering a cup position of 40olateral abduction and 15oanteversion. The results show that the difference in contact pressure between the normal and chamfer models was not substantial in the given orientation of the cup. Also, the increase of the chamfer angle has a small influence on the maximum contact pressures, although that could be also dependent on the reduction of the polyethylene thickness. Pre-clinical testing of total hip prostheses using Finite Element Method enables the evaluation of contact pressures and stress distribution, and proves to be a valuable tool to analyze the parameters reducing the contact pressure.


Author(s):  
Felix Fischer ◽  
Niklas Bauer ◽  
Hubertus Murrenhoff ◽  
Katharina Schmitz

The macroscopic geometry of ball seat valves is important for the quality of the seal. This works discusses the influence of different geometric properties on the contact area, the contact pressure and their relation to the leakage. The leakage is calculated using the results of finite element method (FEM) calculations and Persson’s percolation based method. The following properties of the seat are examined: the angle, the curvature and the eccentricity.


2016 ◽  
Author(s):  
Sarwo Edy Pranoto ◽  
Royan Hidayat ◽  
Mohammad Tauviqirrahman ◽  
Athanasius P. Bayuseno

2021 ◽  
Vol 328 ◽  
pp. 07014
Author(s):  
Wahyu Dwi Lestari ◽  
Luluk Edahwati ◽  
Wiliandi Saputro ◽  
Ahmad Khairul Faizin ◽  
Radissa Dzaky Issafira ◽  
...  

A common problem with artificial hip replacements is increased wear of the material in contact. Materials that are in contact result in contact pressure caused by the patient's daily activities so that it triggers wear. This study adopts a finite element method (FEM) to predict wear of the artificial hip joint, by studying the behavior of a hip joint prosthesis that has clearance under a certain load. The aim of this study was to observe contact as a function of clearance and body weight. The modeling uses metal as femoral head and polycarbonate urethane (PCU) material as the acetabular cup. Contact modeling as a hard material in contact with a deformable material. Four variations of clearance (0.001, 0.005, 0.01, 0.016) and three variations of body weight (500N, 700N, and 1000N) were used in this study. The simulation results show that the lower the distance and weight, the lower the contact pressure.