Newborn Screening for Hereditary Tyrosinemia Type I in Québec: Update

Author(s):  
Yves Giguère ◽  
Marie-Thérèse Berthier
2001 ◽  
Vol 20 (3) ◽  
pp. 241-244
Author(s):  
John Pohl ◽  
Catherine Hughes ◽  
Michael Farrell

2003 ◽  
Vol 39 (6) ◽  
pp. 901-909 ◽  
Author(s):  
Marjanka C Luijerink ◽  
Saskia M.M Jacobs ◽  
Ellen A.C.M van Beurden ◽  
Leander P Koornneef ◽  
Leo W.J Klomp ◽  
...  

MedChemComm ◽  
2018 ◽  
Vol 9 (2) ◽  
pp. 264-274 ◽  
Author(s):  
Venkanna Muripiti ◽  
Brijesh Lohchania ◽  
Srujan Kumar Marepally ◽  
Srilakshmi V. Patri

Receptor mediated gene delivery to the liver offers advantages in treating genetic disorders such as hemophilia and hereditary tyrosinemia type I (HTI).


1993 ◽  
Vol 91 (4) ◽  
pp. 1816-1821 ◽  
Author(s):  
E A Kvittingen ◽  
H Rootwelt ◽  
P Brandtzaeg ◽  
A Bergan ◽  
R Berger

2009 ◽  
Vol 55 (12) ◽  
pp. 2207-2213 ◽  
Author(s):  
Barbara W Adam ◽  
Timothy H Lim ◽  
Elizabeth M Hall ◽  
W Harry Hannon

Abstract Background: Succinylacetone (SUAC) is the primary metabolite accumulated in tyrosinemia type I—an inborn error of metabolism that, if untreated, can cause death from liver failure during the first months of life. Newborn screening laboratories measure SUAC in dried blood spot (DBS) samples to detect asymptomatic tyrosinemia type I. We used panels of SUAC-enriched DBSs to compare and evaluate the performance of these screening tests. Methods: We prepared sets of DBS materials enriched with predetermined SUAC concentrations and distributed samples of these materials, along with a screening practices questionnaire, to laboratories that perform SUAC tests. We compared their reported SUAC concentrations and questionnaire responses to identify screening practices that affect SUAC test outcomes. Results: Data from 2 pilot surveys showed large differences among laboratories in SUAC recoveries, reproducible within-laboratory recoveries, and stable performance of the DBS materials. Results from 257 proficiency test analyses contained a total of 6 false-negative misclassifications. Reported recoveries of added SUAC ranged from 0 to >200%. Low-biased SUAC recoveries were associated with 1 method used by 5 laboratories. All laboratories that reported SUAC recoveries ≥100% used DBS matrix calibrators. Conclusions: The wide ranges of SUAC concentrations reported for pilot and proficiency testing specimens demonstrate a need to harmonize quantitative results among laboratories. Although DBS matrix calibrators are important for optimizing SUAC recoveries, the preparation of these calibrators is not standardized among laboratories. Certified DBS-based SUAC calibrators are needed for accuracy and harmonization.


2001 ◽  
Vol 47 (8) ◽  
pp. 1424-1429 ◽  
Author(s):  
Andreas Schulze ◽  
David Frommhold ◽  
Georg F Hoffmann ◽  
Ertan Mayatepek

Abstract Background: Hereditary tyrosinemia type I (HT) fulfills the criteria for inclusion in neonatal screening programs, but measurement of tyrosine lacks clinical specificity and quantitative assay of succinylacetone is laborious. We developed a semiquantitative assay based on inhibition of δ-aminolevulinate dehydratase (ALA-D) by succinylacetone. Methods: Preincubation of 3-mm discs from dried-blood spots and reaction of the enzyme with δ-aminolevulinic acid as substrate were performed in microtiter plates. After separation of the supernatant and 10 min of color reaction with modified Ehrlich reagent, the formation of porphobilinogen was measured at 550 nm in a plate reader. Results: The detection limit for succinylacetone was 0.3 μmol/L; imprecision (CV) was <5.5% within-run and 10–16% between-run. Storage of blood spots at ambient temperature for several days led to a significant decrease of ALA-D activity. Enzyme activity was lost in filter cards at 45 °C, but remained stable at 2–37 °C. Enzyme activity was decreased in EDTA blood. The absorbance at 550 nm was 0.221 (± 0.073) in healthy neonates and 0.043–0.100 in 11 patients with HT. All neonates with increased tyrosine (above the 99.5th centile) in neonatal screening (97 of 47 000) had normal results by the new assay. Conclusions: The spectrophotometric microassay for ALA-D is a simple and sensitive test for HT. This represents a basis for further examination of its general reliability as a confirmatory test if tyrosine is found to be increased.


2001 ◽  
Vol 20 (3) ◽  
pp. 241-244
Author(s):  
John F. Pohl ◽  
Catherine Hughes ◽  
Michael K. Farrell

2010 ◽  
Vol 68 ◽  
pp. 401-401
Author(s):  
E Barkaoui ◽  
S Mannai ◽  
H Mestiri ◽  
K Boujemaa ◽  
S Abbès

2012 ◽  
Vol 35 (5) ◽  
pp. 831-836 ◽  
Author(s):  
A. Schlune ◽  
E. Thimm ◽  
D. Herebian ◽  
U. Spiekerkoetter

Sign in / Sign up

Export Citation Format

Share Document