Evaluation of Sensory Feedback from a Robotic Hand: A Preliminary Study

Author(s):  
İpek Karakuş ◽  
Hasan Şahin ◽  
Ahmet Atasoy ◽  
Erkan Kaplanoğlu ◽  
Mehmed Özkan ◽  
...  
Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1173
Author(s):  
Mingxiao Liu ◽  
Samuel Wilder ◽  
Sean Sanford ◽  
Soha Saleh ◽  
Noam Y. Harel ◽  
...  

Sensory feedback from wearables can be effective to learn better movement through enhanced information and engagement. Facilitating greater user cognition during movement practice is critical to accelerate gains in motor function during rehabilitation following brain or spinal cord trauma. This preliminary study presents an approach using an instrumented glove to leverage sense of agency, or perception of control, to provide training feedback for functional grasp. Seventeen able-bodied subjects underwent training and testing with a custom-built sensor glove prototype from our laboratory. The glove utilizes onboard force and flex sensors to provide inputs to an artificial neural network that predicts achievement of “secure” grasp. Onboard visual and audio feedback was provided during training with progressively shorter time delay to induce greater agency by intentional binding, or perceived compression in time between an action (grasp) and sensory consequence (feedback). After training, subjects demonstrated a significant reduction (p < 0.05) in movement pathlength and completion time for a functional task involving grasp-move-place of a small object. Future work will include a model-based algorithm to compute secure grasp, virtual reality immersion, and testing with clinical populations.


Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2379
Author(s):  
Se Hoon Kim ◽  
Seo Jung Yun ◽  
Quoc Khanh Dang ◽  
Youngjoon Chee ◽  
Sun Gun Chung ◽  
...  

Stooped posture, which is usually aggravated during walking, is one of the typical postural deformities in patients with parkinsonism. However, the degree of stooped posture is difficult to quantitatively measure during walking. Furthermore, continuous feedback on posture is also difficult to provide. The purpose of this study is to measure the degree of stooped posture during gait and to investigate whether vibration feedback from sensor modules can improve a patient’s posture. Parkinsonian patients with stooped posture were recruited for this study. Two wearable sensors with three-axis accelerometers were attached, one at the upper neck and the other just below the C7 spinous process of the patients. After being calibrated in the most upright posture, the sensors continuously recorded the sagittal angles at 20 Hz and averaged the data at every second during a 6 min walk test. In the control session, the patients walked with the sensors as usual. In the vibration session, sensory feedback was provided through vibrations from the neck sensor module when the sagittal angle exceeded a programmable threshold value. Data were collected and analyzed successfully in a total of 10 patients. The neck flexion and back flexion were slightly aggravated during gait, although the average change was <10° in most patients in both measurement sessions. Therefore, it was difficult to evaluate the effect of sensory feedback through vibration. However, some patients showed immediate response to the feedback and corrected their posture during gait. In conclusion, this preliminary study suggests that stooped posture could be quantitatively measured during gait by using wearable sensors in patients with parkinsonism. Sensory feedback through vibration from sensor modules may help in correcting posture during gait in selected patients.


Author(s):  
John H.L. Watson ◽  
John L. Swedo ◽  
R.W. Talley

A preliminary study of human mammary carcinoma on the ultrastructural level is reported for a metastatic, subcutaneous nodule, obtained as a surgical biopsy. The patient's tumor had responded favorably to a series of hormonal therapies, including androgens, estrogens, progestins, and corticoids for recurring nodules over eight years. The pertinent nodule was removed from the region of the gluteal maximus, two weeks following stilbestrol therapy. It was about 1.5 cms in diameter, and was located within the dermis. Pieces from it were fixed immediately in cold fixatives: phosphate buffered osmium tetroxide, glutaraldehyde, and paraformaldehyde. Embedment in each case was in Vestopal W. Contrasting was done with combinations of uranyl acetate and lead hydroxide.


Author(s):  
H.D. Geissinger ◽  
C.K. McDonald-Taylor

A new strain of mice, which had arisen by mutation from a dystrophic mouse colony was designated ‘mdx’, because the genetic defect, which manifests itself in brief periods of muscle destruction followed by episodes of muscle regeneration appears to be X-linked. Further studies of histopathological changes in muscle from ‘mdx’ mice at the light microscopic or electron microscopic levels have been published, but only one preliminary study has been on the tibialis anterior (TA) of ‘mdx’ mice less than four weeks old. Lesions in the ‘mdx’ mice vary between different muscles, and centronucleation of fibers in all muscles studied so far appears to be especially prominent in older mice. Lesions in young ‘mdx’ mice have not been studied extensively, and the results appear to be at variance with one another. The degenerative and regenerative aspects of the lesions in the TA of 23 to 26-day-old ‘mdx’ mice appear to vary quantitatively.


Author(s):  
J P Cassella ◽  
V Salih ◽  
T R Graham

Left ventricular assist systems are being developed for eventual long term or permanent implantation as an alternative to heart transplantation in patients unsuitable for or denied the transplant option. Evaluation of the effects of these devices upon normal physiology is required. A preliminary study was conducted to evaluate the morphology of aortic tissue from calves implanted with a pneumatic Left Ventricular Assist device-LVAD. Two 3 month old heifer calves (calf 1 and calf 2) were electively explanted after 128 days and 47 days respectively. Descending thoracic aortic tissue from both animals was removed immediately post mortem and placed into karnovsky’s fixative. The tissue was subsequently processed for transmission electron microscopy (TEM). Some aortic tissue was fixed in neutral buffered formalin and processed for routine light microscopy.


2021 ◽  
Author(s):  
Hicham Zaroual ◽  
El Mestafa El Hadrami ◽  
Romdhane Karoui

This study examines the feasibility of using front face fluorescence spectroscopy (FFFS) to authenticate 41 virgin olive oil (VOO) samples collected from 5 regions in Morocco during 2 consecutive crop seasons.


Sign in / Sign up

Export Citation Format

Share Document