Study on Components Match of Solar-Ground Source Heat Pump and Heating Network Complementary Heating System in Severe Cold Region

Author(s):  
Hong Hao ◽  
Xiujuan Zhao ◽  
Guohui Feng ◽  
Xiangyuan Xue
2020 ◽  
Vol 5 ◽  
pp. 11
Author(s):  
Sabrin Korichi ◽  
Bachir Bouchekima ◽  
Nabiha Naili ◽  
Messaouda Azzouzi

Motivated by the rapid spread of the novel pandemic disease (COVID-19) that swept the most countries in the world, a new radiation heating system consists of wall radiator panel system connected to a reversible geothermal heat pump (GHP) coupled with horizontal ground heat exchanger (HGHX) was proposed as fast and permanent solution to the risks of the dispersion of airborne infectious diseases in air-conditioned enclosed spaces. An experimental system was installed and tested in the laboratory of thermal process of Research and Technology Center of Energy (CRTEn), Tunisia, in order to achieve the two main goals of this work: developing a new radiation heating system with quick and inexpensive implementation while ensuring high efficiency and environment-friendly performance for the entire system. The results obtained show that it is feasible to use the novel RPHs as heat rejecter of the horizontal ground source heat pump system (HGSHPs) for heating buildings with limited surface land areas epically those located in the Mediterranean regions such as Tunisia, the average performance coefficients of the geothermal heat pump COPhp and the overall system COPsys are found to be 6.3 and 3, respectively. The thermal comfort analysis indicates that there is only a small vertical temperature fluctuation in the test room that would not produce any negative effect on thermal comfort.


2020 ◽  
Vol 2020 ◽  
pp. 1-18 ◽  
Author(s):  
Yan Gao ◽  
Zhi Sun ◽  
Xinxing Lin ◽  
Chuang Wang ◽  
Zongyu Sun ◽  
...  

The cold accumulation problem can lead to performance degradation of heat pumps. This paper presents the design and optimization of a solar-assisted storage system to solve this issue. A ground source heat pump (GSHP) project was established using the transient system simulation program (TRNSYS) based on a ground heat exchange theoretical model, which was validated by a previously established experiment in Beijing. The Beijing, Harbin, and Zhengzhou regions were used in numerical simulations to represent three typical cities where buildings require space heating (a cold region, a severe cold region, and a hot summer and cold winter region, respectively). System performance was simulated over periods of ten years. The simulation results showed that the imbalance efficiencies in the Beijing, Harbin, and Zhengzhou regions are 55%, 79%, and 38%, respectively. The annual average soil temperature decreases 7.3°C, 11.0°C, and 5.3°C during ten years of conventional GSHP operation in the Beijing, Harbin, and Zhengzhou regions, respectively. Because of the soil temperature decrease, the minimum heating coefficient of performance (COP) values decrease by 23%, 46%, and 11% over the ten years for GSHP operation in these three regions, respectively. Moreover, the simulation data show that the soil temperature would still be decreasing if based on the previous solar energy area calculation method. Design parameters such as the solar collector size are optimized for the building load and average soil temperature in various cold regions. Long-term operation will test the matching rate of the compensation system with the conventional GSHP system. After the system is optimized, the solar collector area increases of 20% in the Beijing region, 25% in the Harbin region, and 15% in the Zhengzhou region could help to maintain the annual average soil temperature balance. The optimized system could maintain a higher annual average COP because of the steady soil temperature. It provides a method for the design of a solar collector area which needs to be determined in the seasonal heat storage solar ground source heat pump system.


2013 ◽  
Vol 448-453 ◽  
pp. 2790-2793 ◽  
Author(s):  
Jing Bo Zhao

In this paper, the principle of solar assisted heat pump and ground source heat pump was introduced, the comprehensive utilization of solar assisted heat pump and ground source heat pump was discussed in severe cold region, the article illustrated the advantages and matters of the system to which need pay attention, and pointed out that the comprehensive utilization of the combination solar assisted heat pump and ground source heat pump had a substantial economic and environmental benefits in severe cold region.


2014 ◽  
Vol 704 ◽  
pp. 102-112 ◽  
Author(s):  
G.P. Vasilyev ◽  
N.V. Peskov ◽  
A.A. Burmistrov ◽  
N.A. Timofeev ◽  
P.E. Zakharov ◽  
...  

This paper contains the results of research, carried out with financial support from the Ministry of Education and Science of the Russian Federation (contract ID RFMEFI57914X0026). For the ground source heat pump (GSHP) used as a heating system in regions with cold climate the thermal effects of ground moisture freezing-melting processes can make an essential long-term impact on GSHP performance. However, widely known models of heat transfer inside and outside GSHP borehole do not take into account such effects. In this paper we propose a method of engineering estimation of freezing-melting latent heat in the frame of modified cylindrical source model. The key feature of the method is the definition of effective thermal conductivity of ground to "convert" the latent heat of phase transition into equivalent heat flux from outer ground. The method is validated by laboratory measurements of ground thermal conductivity during the freezing-melting process.