Retrofit of Air-Conditioning System in Data Center Using Separate Heat Pipe System

Author(s):  
Yuwei Zheng ◽  
Zhen Li ◽  
Xiaohua Liu ◽  
Zhen Tong ◽  
Rang Tu
2007 ◽  
Vol 2 (3) ◽  
pp. 86-95
Author(s):  
R. Sudhakaran ◽  
◽  
V. Sella Durai ◽  
T. Kannan ◽  
P.S. Sivasakthievel ◽  
...  

2020 ◽  
Vol 160 ◽  
pp. 99-111 ◽  
Author(s):  
Zongwei Han ◽  
Haotian Wei ◽  
Xiaoqing Sun ◽  
Chenguang Bai ◽  
Da Xue ◽  
...  

2020 ◽  
Vol 10 (2) ◽  
pp. 583
Author(s):  
Liping Zeng ◽  
Xing Liu ◽  
Quan Zhang ◽  
Jun Yi ◽  
Xianglong Liu ◽  
...  

This paper deals with the heat transfer performance of a micro-channel backplane heat pipe air conditioning system. The optimal range of the filling rate of a micro-channel backplane heat pipe air conditioning system was determined in the range of 65–75%, almost free from the interference of working conditions. Then, the influence of temperature and air volume flow rate on the heat exchange system were studied. The system maximum heat exchange is 7000–8000 W, and the temperature difference between the inlet and outlet of the evaporator and the condenser is almost 0 °C. Under the optimum refrigerant filling rate, the heat transfer of the micro-channel heat pipe backplane system is approximately linear with the temperature difference between the inlet air temperature of the evaporator and the cooling distribution unit (CDU) inlet water temperature in the range of 18–28 °C. The last part compares the heat transfer characteristics of two refrigerants at different filling rates. The heat transfer, pressure, and refrigerant temperature of R134a and R22 are the same with the change of filling rate, but the heat transfer of R134a is lower than that of R22. The results are of great significance for the operational control and practical application of a backplane heat pipe system.


2016 ◽  
Vol 98 ◽  
pp. 374-379 ◽  
Author(s):  
Z.J. Guo ◽  
J. Shao ◽  
X.H. Li ◽  
R.J. Liu ◽  
Wei Wang ◽  
...  

2014 ◽  
Vol 672-674 ◽  
pp. 518-521
Author(s):  
Li Fei Song ◽  
Tao Li ◽  
Qi Fen Li ◽  
Lin Hui Zhao ◽  
Xin Zhao ◽  
...  

In this paper, the Unicom's medium-sized IDC room in a city of northern China is the research object for the study. Based on field research of the room refrigeration conditions, data center room air conditioning system is carried out to optimize and for energy conservation research. Through the analytic methods of energy saving-technology, the best energy saving solutions is explored.


2014 ◽  
Vol 602-605 ◽  
pp. 928-932
Author(s):  
Min Li ◽  
Yun Wang ◽  
Zheng Qian Feng ◽  
Wang Li

By studying the energy-saving technologies of air-conditioning system in data centers, we designed a intelligent air conditioning system, improved the cooling efficiency of air conditioning system through a reasonable set of hot and cold aisles, reduced the running time of HVAC by using the intelligent heat exchange system, an provided a reference for energy saving research of air conditioning system of data centers.