Small Angle X-Ray Scattering (SAXS) with Synchrotron Radiation Sources

2014 ◽  
pp. 337-359
Author(s):  
Stefano Polizzi ◽  
Francesco Spinozzi
1997 ◽  
Vol 30 (5) ◽  
pp. 816-821 ◽  
Author(s):  
W. Bras ◽  
A. J. Ryan

The high X-ray intensity of synchrotron radiation (SR) beamlines makes it possible to perform time-resolved small-angle X-ray scattering (SAXS) experiments. The information that can be obtained by collecting the wide-angle diffraction pattern simultaneously not only increases the information content of an experiment but also increases the reliability of the time-correlations between SAXS and WAXS (wide-angle X-ray scattering) patterns. This is a great advantage for experiments with a time resolution below the level of 1 s per frame. With appropriate instrumentation, this is a time domain that is routinely accessible for a large group of research fields. This has had a considerable impact upon the understanding of fundamental aspects of phase transformations. Not only fundamental processes but also more applied fields have benefited from these developments. In polymer research this has led to a situation in which it has become possible to simulate materials processing techniques on-line. With the advent of third-generation synchrotron-radiation sources (e.g. ESRF, APS, Spring8), it has become possible to develop SAXS/WAXS beamlines that will open up new research opportunities by utilizing the higher intensity, the tuneability and the higher collimation offered by these SR sources. However, some of the instrumentation limits in detector and sample environments that have become apparent in research on second-generation synchrotron-radiation sources still have not been appropriately addressed, which means that in some fields it will not be possible to take full advantage of the superior X-ray beam quality that third-generation synchrotrons can offer. A way in which these instrumentation limits can be overcome is discussed, and the instrumentation for a new bending-magnet beamline at the ESRF is used as an example.


2012 ◽  
Vol 45 (3) ◽  
pp. 307-312 ◽  
Author(s):  
Takamichi Shinohara ◽  
Tomoko Shirahase ◽  
Daiki Murakami ◽  
Taiki Hoshino ◽  
Moriya Kikuchi ◽  
...  

Rare Metals ◽  
2012 ◽  
Vol 31 (6) ◽  
pp. 537-540
Author(s):  
Jianbo Zhang ◽  
Yongan Zhang ◽  
Baohong Zhu ◽  
Ruiqing Liu ◽  
Zhihui Li ◽  
...  

FEBS Letters ◽  
1997 ◽  
Vol 415 (2) ◽  
pp. 183-185 ◽  
Author(s):  
Jun-Mei Zhou ◽  
Ying-Xin Fan ◽  
Hiroshi Kihara ◽  
Kazumoto Kimura ◽  
Yoshiyuki Amemiya

1997 ◽  
Vol 30 (1) ◽  
pp. 49-54 ◽  
Author(s):  
J.-M. Dubuisson ◽  
T. Decamps ◽  
P. Vachette

An evacuated, temperature-controlled cell has been built for use on the small-angle X-ray scattering instrument D24 at the synchrotron radiation facility LURE. The sample is placed in a quartz capillary sealed in a stainless-steel holder using a vacuum-tight glue. Several O rings provide a vacuum path upstream and downstream from the cell, so that the X-ray beam only meets the capillary walls and the solution under study between the slits and the beam stop, while the sample is maintained under atmospheric pressure. The cell temperature is controlled via a water circulation through a copper sheath in tight contact with the steel holder. The use of this cell results in a marked reduction of the background, as observed in two series of parallel experiments using a conventional cell and this evacuated cell. The decrease ranges from a factor of 2 at s 1 values larger than 0.008 Å−1 to more than 15 at s = 0.00116 Å−1, where s is the modulus of the scattering vector (s = 2sin θ/λ, 2θ is the scattering angle and λ is the wavelength of the X-rays).


Sign in / Sign up

Export Citation Format

Share Document