quartz capillary
Recently Published Documents


TOTAL DOCUMENTS

45
(FIVE YEARS 10)

H-INDEX

8
(FIVE YEARS 1)

2021 ◽  
Author(s):  
Lai Xing Cheng ◽  
Wen Hao Ye ◽  
Xiao Shan Guo ◽  
Zhihui Zhang ◽  
Chao C. Jiang

Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4445
Author(s):  
Fintan McGuinness ◽  
Aidan Cloonan ◽  
Mohamed Oubaha ◽  
Dinesh Babu Duraibabu ◽  
M. Mahmood Ali ◽  
...  

The following presents a comparison of an extrinsic Fabry–Perot interferometer (EFPI)-based temperature sensor, constructed using a novel diaphragm manufacturing technique, with a reference all-glass EFPI temperature sensor. The novel diaphragm was manufactured using polyvinyl alcohol (PVA). The novel sensor fabrication involved fusing a single-mode fibre (SMF) to a length of fused quartz capillary, which has an inner diameter of 132 μm and a 220 μm outer diameter. The capillary was subsequently polished until the distal face of the capillary extended approximately 60 μm beyond that of the single mode fibre. Upon completion of polishing, the assembly is immersed in a solution of PVA. Controlled extraction resulted in creation of a thin diaphragm while simultaneously applying a protective coating to the fusion point of the SMF and capillary. The EFPI sensor is subsequently sealed in a second fluid-filled capillary, thereby creating a novel temperature sensor structure. Both temperature sensors were placed in a thermogravimetric analyser and heated from an indicated 30 °C to 100 °C to qualitatively compare sensitivities. Initial results indicated that the novel manufacturing technique both expedited production and produces a more sensitive sensor when compared to an all-glass construction.


2021 ◽  
Vol 54 (1) ◽  
pp. 371-375
Author(s):  
Paul Monceyron Røren ◽  
Kristoffer W. B. Hunvik ◽  
Vegard Josvanger ◽  
Ole Tore Buseth ◽  
Jon Otto Fossum

A sample cell for powder X-ray diffraction studies with in situ applied pressure and control of temperature is demonstrated. The cell is based on a previously reported design and consists of a glass or quartz capillary glued into a Swagelok weld gland; this configuration can hold up to 100 bar (1 bar = 100 kPa). The cell is placed in contact with a copper plate for control of temperature between −30 and 200°C. This is achieved by Peltier elements, heat cartridges and a refrigerated circulating bath. This work mainly focuses on the temperature control system. Commissioning tests were performed in a custom-made small/wide-angle X-ray diffractometer at the Norwegian University of Science and Technology. The system is easily portable to synchrotron facilities.


2021 ◽  
Author(s):  
Xiping Zhu ◽  
Hailin Chen ◽  
Chao Jiang ◽  
Xiaoshan Guo ◽  
Han Zhang ◽  
...  

Micromachines ◽  
2019 ◽  
Vol 10 (10) ◽  
pp. 685
Author(s):  
Kangning Wang ◽  
Di Wu ◽  
Wenming Wu

A self-activated micropump which is capable of stable velocity transport for a liquid to flow a given distance inside a 3D microchannel has been a dream of microfluidic scientists for a long time. A new self-activated pumping mechanism has been proposed in this paper. It is different from the authors’ previous research which relied on the fluid resistance of a quartz capillary tube or end-blocked gas-permeable silicone or a polydimethylsiloxane (PDMS) wall to automate the flow. In this research, an end-open stretched Teflon tube was utilized for passive transport for the first time. A new fluid transmission mode was adopted with the assistance of a cheaper easily accessible oil mixture to achieve stable continuous flow. Finally, this novel micropump has been applied to real-time continuous-flow polymerase chain reactions (PCRs), with an amplification efficiency similar to that of a commercial PCR cycler instrument.


Polymers ◽  
2019 ◽  
Vol 11 (6) ◽  
pp. 946 ◽  
Author(s):  
Meng-ge Huangfu ◽  
Yan Zhang ◽  
Xin-ling Zhang ◽  
Jin-gang Liu ◽  
Ying-cong Liu ◽  
...  

Protection of intrinsically brittle quartz chromatographic columns (CCs) from breakage or property deterioration in gas chromatography (GC) analysis has become an important research topic regarding high-temperature GC techniques. Polyimide (PI) has proved to be the most suitable protective coating for quartz CCs. In the current research, a series of novel high-temperature-resistant PI coatings for quartz CCs operated over 320 °C have been successfully prepared. For this purpose, the aromatic diamine with a rigid skeleton structure 2-(4-aminophenyl)-5-aminobenzimidazole (APBI) was copolymerized with two aromatic dianhydrides—3,3’,4,4’-benzophenotetracarboxylic acid dianhydride (BTDA) and 4,4’-oxydiphthalic anhydride (ODPA)—and an aromatic diamine with flexible ether linkages—4,4’-oxydianiline (ODA)—by a two-step polymerization procedure via soluble poly(amic acid) (PAA) precursors, followed by thermal imidization at elevated temperatures. The developed PI coatings exhibited good comprehensive properties, including glass transition temperatures (Tg) as high as 346.9 °C, measured by dynamic mechanical analysis (DMA), and coefficients of linear thermal expansion (CTEs) as low as 24.6 × 10−6/K in the range of 50–300 °C. In addition, the PI coatings exhibited good adhesion to the fused quartz capillary columns. No cracking, delamination, warpage, or other failures occurred during the 100-cycle thermal shock test in the range of 25–320 °C.


Micromachines ◽  
2019 ◽  
Vol 10 (6) ◽  
pp. 350 ◽  
Author(s):  
Di Wu ◽  
Bing Shi ◽  
Bin Li ◽  
Wenming Wu

The self-activated micropump capable of velocity-stable transport for both single-phased plug and double-phased droplet through long flow distance inside 3D microchannel is one dream of microfluidic scientists. While several types of passive micropumps have been developed based on different actuation mechanisms, until today, it is still one bottleneck to realize such a satisfied self-activated micropump for the stable delivery of both single and double-phased liquid inside long microchannel (e.g., several meters), due to the lack of innovative mechanism in previous methods. To solve this problem, in this article, we propose a new self-activated pumping mechanism. Herein, an end-opened gas-impermeable quartz capillary is utilized for passive transport. Mechanism of this micropump is systemically studied by both the mathematical modeling and the experimental verifications. Based on the flow assays, it totally confirmed a different pumping principle in this paper, as compared with our previous works. The R 2 value of the overall flow rates inside the 3D microchannel is confirmed as high as 0.999, which is much more homogeneous than other passive pumping formats. Finally, this novel micropump is applied to continuous-flow real-time PCRs (both plug-type and microdroplet-type), with the amplification efficiency reaching 91.5% of the commercial PCR cycler instrument.


2019 ◽  
Vol 127 (10) ◽  
pp. 692
Author(s):  
А.С. Матросова ◽  
С.К. Евстропьев ◽  
Л.Ю. Миронов ◽  
Н.В. Никоноров ◽  
А.В. Комаров ◽  
...  

AbstractThe model of a fiber optic sensor device which operational principle is based on the thermal quenching of luminescence for ambient temperature measurements was experimentally studied. The construction of a multimode optical fiber with a transmission of more than 90%/m in the spectral region from 350 to 650 nm and a quartz capillary filled with a photoactive polymer composition based on epoxyacrylate and the europium complex with 2-naphthoyltrifluoroacetone and trioctylphosphinoxide was used as a sensitive sensor element. An exponentially decreasing character of the temperature dependence of the luminescence intensity was discovered for the photoactive composition incorporated into the sensor (excitation wavelength, 355 nm; luminescence wavelength, 615 nm) within a range from 20 to 100°C. A quasi-linear change in the luminescence intensity depending on the power of the launched UV radiation was determined.


Sign in / Sign up

Export Citation Format

Share Document