Pattern Reversal Electroretinograms in Squint Amblyopia, Artificial Anisometropia and Simulated Eccentric Fixation

Author(s):  
H. E. Persson ◽  
P. Wanger
2020 ◽  
Vol 6 (2) ◽  
pp. 74-77
Author(s):  
Mohammad Enayet Hussain ◽  
Bithi Debnath ◽  
AFM Al Masum Khan ◽  
Md Ferdous Mian ◽  
Md Nahidul Islam ◽  
...  

Background: The visual evoked potentials (VEP) is a valuable tool to document occult lesions of the central visual channels especially within the optic nerve. Objectives: The purpose of the present study was to observe the findings of first few cases of VEP done in the neurophysiology department of the National Institute of Neurosciences (NINS), Dhaka, Bangladesh. Methodology: This cross-sectional study was conducted in the Department of Neurophysiology at the National Institute of Neurosciences and Hospital, Dhaka, Bangladesh from September 2017 to March 2020. All patients referred to the Neurophysiology Department of NINS for VEP were included. Pattern reversal VEPs were done using standard protocol set by International Federation of Clinical Neurophysiology (IFCN). Results: The mean age of the study population was 30.70 (±12.11) years (6-68 years) with 31 (46.3%) male and 36 (53.7%) female patients. The mean duration of illness was 8.71 (±1.78) months (3 days- 120 months). Most common presenting symptom was blurring of vision (37.3%) and dimness of vision (32.8%). Patterned VEP revealed mixed type (both demyelinating and axonal) of abnormality in most cases [29(43.35)]. The most common clinical diagnosis was multiple sclerosis (29.85%) and optic neuropathy (26.87%). In the clinically suspected cases of multiple sclerosis, optic neuropathy and optic neuritis most of the cases of VEP were abnormal and the p value is 0.04 in optic neuropathy and optic neuritis. Conclusion: The commonest presentation of the patients in this series were blurring of vision and dimness of vision. The most common clinical diagnosis for which VEP was asked for, was optic neuritis and multiple sclerosis. Most abnormalities were of mixed pattern (demyelinating and axonal). Journal of National Institute of Neurosciences Bangladesh, 2020;6(2): 74-77


2015 ◽  
Vol 8 (2) ◽  
pp. 2106-2121
Author(s):  
Hamed Ibrahem Abdelkader ◽  
Mona Abdelkader ◽  
Mohammed Kabeel ◽  
Malak Alya

Visual evoked potentials (VEPS) are obtained from optic tract by recording the evoked potentials generated by retinal stimulation. The flash VEP (FVEP) is used less frequently than pattern reversal VEP (PRVEP) because; it shows great variation in both latency and amplitude. The present study was undertaken to evaluate the effect of change of wavelength of flash and change of check size on the parameters of visual evoked potential (amplitude and latency) in normal individuals and glaucoma patients. The group of healthy subjects in the age of 20-45 years while the group of glaucoma subjects where  in the age of 25-50 years.  The two groups were exposed to flash VEP with white light and blue color and they also were exposed to checks subtending a visual angles of 15, 30,60 and 120 minutes of arc. The measured data were statistically analyzed and summarized by histograms. The interindividual and intraindividual in latencies and amplitudes for FVEP were assessed using  the coefficient of variation (COV). In conclusion, monochromatic flash VEP was preferred than white as there were minimal inter and intra individual variation of latencies and amplitudes. The most preferred check size in PRVEP was 120' for  the two groups.  


Author(s):  
Jan Kremláček ◽  
Jana Nekolová ◽  
Markéta Středová ◽  
Jana Langrová ◽  
Jana Szanyi ◽  
...  

Abstract Background For patients with age-related macular degeneration (AMD), a special intraocular lens implantation partially compensates for the loss in the central part of the visual field. For six months, we evaluated changes in neurophysiological parameters in patients implanted with a “Scharioth macula lens” (SML; a center near high add + 10 D and peripheral plano carrier bifocal lens designed to be located between the iris and an artificial lens). Methods Fourteen patients (5 M, 9 F, 63–87 years) with dry AMD were examined prior to and at 3 days after, as well as 1, 2, and 6 months after, implantation using pattern-reversal, motion-onset, and cognitive evoked potentials, psychophysical tests evaluating distant and near visual acuity, and contrast sensitivity. Results Near visual acuity without an external aid was significantly better six months after implantation than before implantation (Jaeger table median (lower; upper quartile): 4 (1; 6) vs. 15 (13; 17)). Distant visual acuity was significantly altered between the pre- (0.7 (0.5; 0.8) logMAR) and last postimplantation visits (0.8 (0.7; 0.8) logMAR), which matched prolongation of the P100 peak time (147 (135; 151) ms vs. 161 (141; 166) ms) of 15 arc min pattern-reversal VEPs and N2 peak time (191.5 (186.5; 214.5) ms vs. 205 (187; 218) ms) of peripheral motion-onset VEPs. Conclusion SML implantation significantly improved near vision. We also observed a slight but significant decrease in distant and peripheral vision. The most efficient electrophysiological approach to test patients with SML was the peripheral motion-onset stimulation, which evoked repeatable and readable VEPs.


1960 ◽  
Vol 44 (8) ◽  
pp. 472-491 ◽  
Author(s):  
K. Wybar ◽  
B. Thatcher
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document