In-Situ Determination of Chlorinated Hydrocarbons in Ground Waters Using a Fiber Optic Evanescent Wave Sensor

Author(s):  
J. Bürck ◽  
J. Conzen ◽  
G. Klunder ◽  
B. Zimmermann ◽  
H. Ache
1993 ◽  
Vol 47 (9) ◽  
pp. 1484-1487 ◽  
Author(s):  
R. Krska ◽  
K. Taga ◽  
R. Kellner

In this work the development and validation of a new MIR fiber-optic physicochemical sensor system for the continuous in situ analysis of chlorinated hydrocarbons (CHCs) in water is described. This study took advantage of the selectivity and sensitivity of fiber evanescent wave spectroscopy (FEWS) and the recent development of polycrystalline silver halide fibers. Since these fibers are transparent up to 20 μm, it was possible for the first time to develop a fiber-optic sensing system for CHCs, which have their strongest absorption bands > 10 μm. The silver halide fibers were coated with low-density polyethylene (LDPE) to enrich the CHC within the evanescent wave and to exclude the IR absorbing water from the measurement. For the quantitative in situ FEWS measurements, the coated silver halide fibers were coupled to a Fourier transform infrared (FT-IR) spectrometer using an off-axis parabolic mirror and a fiber-detector coupling system. This setup enabled the simultaneous in situ detection of the most common chlorinated hydrocarbons in concentrations between 1 to 50 mg/L in water by employing a fiber sensing part only 10 cm in length. A comparative analysis of waste water samples under participation of two experienced head space-gas chromatography (HSGC) laboratories showed good agreement of this continuous sensor system with the established standard techniques. The resulting working curve for tetrachloroethylene showed a correlation coefficient of r2 = 0.968 and a relative standard deviation of 17% in the range from 1 to 10 ppm.


2002 ◽  
Author(s):  
Richard B. Thompson ◽  
Hui-Hui Zeng ◽  
Carol A. Fierke ◽  
Gary Fones ◽  
James W. Moffett

1997 ◽  
Vol 51 (2) ◽  
pp. 247-252 ◽  
Author(s):  
Jeffrey F. Aust ◽  
Karl S. Booksh ◽  
Christopher M. Stellman ◽  
Richard S. Parnas ◽  
Michael L. Myrick

A method for real-time determination of the percent cure of epoxies via in situ fiber-optic Raman spectroscopy has been developed. This method utilizes a probe design developed for real-time monitoring of polymer curing and multivariate analysis to interpret the data and determine percent cure. This method was demonstrated to be reliable to ±0.54% of cure in laboratory samples over a 50–99% cure range. A preliminary study measuring cure percentage in an industrial, glass-reinforced composite has been shown to be reliable to ±0.82% in the 40–90% cure range.


2018 ◽  
Vol 6 (19) ◽  
pp. 5161-5170 ◽  
Author(s):  
Xuejun Zhang ◽  
Shunshuo Cai ◽  
Fu Liu ◽  
Hao Chen ◽  
Peiguang Yan ◽  
...  

In situ determination of the complex permittivity of H2-infused palladium using near infrared plasmons over optical fibers.


1994 ◽  
pp. 254
Author(s):  
Teresa McCormack ◽  
Richard O'Kennedy ◽  
Gerard O'Keeffe ◽  
Brian MacCraith

Sign in / Sign up

Export Citation Format

Share Document