Real-time in-situ determination of free Cu(II) at picomolar levels in sea water using a fluorescence lifetime-based fiber optic biosensor

2002 ◽  
Author(s):  
Richard B. Thompson ◽  
Hui-Hui Zeng ◽  
Carol A. Fierke ◽  
Gary Fones ◽  
James W. Moffett
1997 ◽  
Vol 51 (2) ◽  
pp. 247-252 ◽  
Author(s):  
Jeffrey F. Aust ◽  
Karl S. Booksh ◽  
Christopher M. Stellman ◽  
Richard S. Parnas ◽  
Michael L. Myrick

A method for real-time determination of the percent cure of epoxies via in situ fiber-optic Raman spectroscopy has been developed. This method utilizes a probe design developed for real-time monitoring of polymer curing and multivariate analysis to interpret the data and determine percent cure. This method was demonstrated to be reliable to ±0.54% of cure in laboratory samples over a 50–99% cure range. A preliminary study measuring cure percentage in an industrial, glass-reinforced composite has been shown to be reliable to ±0.82% in the 40–90% cure range.


1991 ◽  
Vol 222 ◽  
Author(s):  
B. Johs ◽  
J. L. Edwards ◽  
K. T. Shiralagi ◽  
R. Droopad ◽  
K. Y. Choi ◽  
...  

ABSTRACTA modular spectroscopic ellipsometer, capable of both in-situ and ex-situ operation, has been used to measure important growth parameters of GaAs/AIGaAs structures. The ex-situ measurements provided layer thicknesses and compositions of the grown structures. In-situ ellipsometric measurements allowed the determination of growth rates, layer thicknesses, and high temperature optical constants. By performing a regression analysis of the in-situ data in real-time, the thickness and composition of an AIGaAs layer were extracted during the MBE growth of the structure.


2020 ◽  
Vol 13 ◽  
pp. 247
Author(s):  
N. Evaggeliou ◽  
Ch. Lykomitrou ◽  
A. Zafiropoulou

In the present study a comparative evaluation of two methods for 137Cs determination (pretreatment for gamma spectrometry) is attempted. One of them is the conventional AMP (ammonium molybdophosphate, (ΝΗ4)3Ρ(Μo3O10)4) method (radiochemical treatment based on coprecipitation) and the other one is a method based on pre-concentration of cesium in situ by using the Mark III Centrifugal Pump. The pump, which is described analytically in the study, is composed of a mo­tor (pump), four cartridge housings (containing the scavengers), a flow meter and a pressure tube (containing the battery pack and the timer board). For justification, this method is compared with the AMP co-precipitation one. Following up the radioanalytical procedures, the gamma spectrometry system (relative efficiency of high purity germanium detector 90%) is also demonstrated, as conformed to mea­ suring obtained parameters. Finally, the advantages and disadvantages of these two methods are recorded and the application of each one is suggested.


1997 ◽  
Vol 31 (1) ◽  
pp. 87-102 ◽  
Author(s):  
Y. M. Liu ◽  
C. Ganesh ◽  
J. P. H. Steele ◽  
J. E. Jones

2010 ◽  
Author(s):  
Jiefeng Xi ◽  
Yuying Zhang ◽  
Li Huo ◽  
Yongping Chen ◽  
Toufic Jabbour ◽  
...  

2003 ◽  
Vol 74 (10) ◽  
pp. 4442-4447 ◽  
Author(s):  
S. Topcu ◽  
L. Chassagne ◽  
Y. Alayli
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document