Optimal Placement of Solar PV as Active Power Source in Primary Distribution System for Loss Reduction

Author(s):  
Vani Bhargava ◽  
S. K. Sinha ◽  
M. P. Dave
2012 ◽  
Vol 433-440 ◽  
pp. 7190-7194 ◽  
Author(s):  
Nattachote Rugthaicharoencheep ◽  
Thong Lantharthong ◽  
Awiruth Ratreepruk ◽  
Jenwit Ratchatha

This paper presents the optimal and sizing of distributed generation (DG) placement in a radial distribution system for loss reduction. The main emphasis of this paper is to identify proper locations for installing DGs in a distribution system to reduce active power loss and improve bus voltages. Nevertheless, proper placement and sizing of DG units are not straightforward to be identified as a number of their positions and capacities need to be determined. It is therefore proposed in this paper to solve a DG placement problem based on a Tabu search algorithm. The objective function of the problem is to minimize the system loss subject to power flow constraints, bus voltage limits, pre specified number of DGs, and their allowable total installed capacity, and only one distributed generator for one installation position. The effectiveness of the methodology is demonstrated by a practical sized distribution system consisting of 69 bus and 48 load points. The results show that the optimal DG placement and sizing can be identified to give the minimum power loss while respecting all the constraints.


Energies ◽  
2019 ◽  
Vol 12 (21) ◽  
pp. 4062 ◽  
Author(s):  
Vlahinić ◽  
Franković ◽  
Komen ◽  
Antonić

Photovoltaic (PV) system inverters usually operate at unitary power factor, injecting only active power into the system. Recently, many studies have been done analyzing potential benefits of reactive power provisioning, such as voltage regulation, congestion mitigation and loss reduction. This article analyzes possibilities for loss reduction in a typical medium voltage distribution system. Losses in the system are compared to the losses in the PV inverters. Different load conditions and PV penetration levels are considered and for each scenario various active power generation by PV inverters are taken into account, together with allowable levels of reactive power provisioning. As far as loss reduction is considered, there is very small number of PV inverters operating conditions for which positive energy balance exists. For low and medium load levels, there is no practical possibility for loss reduction. For high loading levels and higher PV penetration specific reactive savings, due to reactive power provisioning, increase and become bigger than additional losses in PV inverters, but for a very limited range of power factors.


2021 ◽  
Vol 13 (18) ◽  
pp. 10224
Author(s):  
Sasan Azad ◽  
Mohammad Mehdi Amiri ◽  
Morteza Nazari Heris ◽  
Ali Mosallanejad ◽  
Mohammad Taghi Ameli

Considering the strong influence of distributed generation (DG) in electric distribution systems and its impact on network voltage losses and stability, a new challenge has appeared for such systems. In this study, a novel analytical algorithm is proposed to distinguish the optimal location and size of DGs in radial distribution networks based on a new combined index (CI) to reduce active power losses and improve system voltage profiles. To obtain the CI, active power losses and voltage stability indexes were used in the proposed approach. The CI index with sensitivity analysis was effective in decreasing power losses and improving voltage stability. Optimal DG size was determined based on a search algorithm to reduce active power losses. The considered scheme was examined through IEEE 12-bus and 33-bus radial distribution test systems (RDTS), and the obtained results were compared and validated in comparison with other available methods. The results and analysis verified the effectiveness of the proposed algorithm in reducing power losses and improving the distribution system voltage profiles by determining the appropriate location and optimal DG size. In IEEE 12 and 33 bus networks, the minimum voltage increased from 0.9434 p.u and 0.9039 p.u to 0.9907 p.u and 0.9402 p.u, respectively. Additionally, the annual cost of energy losses decreased by 78.23% and 64.37%, respectively.