Stresses in an anisotropic cylinder

1974 ◽  
Vol 8 (2) ◽  
pp. 277-281
Author(s):  
S. D. Volkov ◽  
Yu. V. Denisov ◽  
N. A. Klinskikh ◽  
M. L. Komissarova
Keyword(s):  
2007 ◽  
Vol 6 (2) ◽  
Author(s):  
Michelle Fritz ◽  
Phil Prior ◽  
Bradley Roth

Background—The electric field applied to the heart during defibrillation causes mechanical forces (electrostriction), and as a result the heart deforms. This paper analyses the physical origin of the deformation, and how significant it is. Methods—We represent the heart as an anisotropic cylinder. This simple geometry allows us to obtain analytical solutions for the potential, current density, charge, stress, and strain. Results—Charge induced on the heart surface in the presence of the electric field results in forces that deform the heart. In addition, the anisotropy of cardiac tissue creates a charge density throughout the tissue volume, leading to body forces. These two forces cause the tissue to deform in a complicated manner, with the anisotropy suppressing radial displacements in favor of tangential ones. Quantitatively, the deformation of the tissue is small, although it may be significant when using some imaging techniques that require the measurement of small displacements. Conclusions—The anisotropy of cardiac tissue produces qualitatively new mechanical behavior during a strong, defibrillation-strength electric shock.


Author(s):  
Alexander V. Kudrin ◽  
Tatyana M. Zaboronkova ◽  
Anna S. Zaitseva ◽  
Catherine Krafft

Sign in / Sign up

Export Citation Format

Share Document